80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
4 Amps
50-60 Hz
550 Watts
Note: All measurements were taken with input voltage at 230 V nominal at 50 Hz. Input AC Current Waveform (ITHD = 26.4%, 50% Load)
0.34 0.83 50.44% 10% 64.94 11.63/0.03 3.36/0.98 5.12/0.98 5.1/0.23 56.48 86.98%
0.60 0.90 38.56% 20% 124.67 11.67/0.05 3.34/1.96 5.11/1.95 5.09/0.45 112.81 90.49%
1.41 0.96 26.40% 50% 311.30 11.82/0.14 3.29/4.89 5.06/4.85 5.06/1.13 282.03 90.60%
2.90 0.98 17.76% 100% 653.70 12.17/0.27 3.21/9.78 4.98/9.69 5.03/2.25 562.17 86.00%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
Aerocool Advanced Technologies Corp.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-30.0
-20.0
-10.0
0.0
10.0
20.0
30.0
-400
-300
-200
-100
0
100
200
300
400
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current