AeroCool Integrator MX 500W Energy label

80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
90.09%
AVERAGE EFFICIENCY :
88.40%
80 PLUS COMPLIANT:
YES
Value Units
Volts
5 Amps
50 Hz
500 Watts
Note: All measurements were taken with input voltage at 230 V nominal at 50 Hz. Input AC Current Waveform (ITHD = 18.66%, 50% Load)
-12V 3.3V 5V 5Vsb
0.34 0.79 29.81% 10% 61.58 11.72/0.02 3.39/0.98 5.07/0.98 5.16/0.2 50.75
82.42%
0.56 0.89 27.65% 20% 115.55 11.7/0.05 3.37/1.96 5.06/1.95 5.14/0.41 101.61
87.94%
1.27 0.96 18.66% 50% 280.80 11.8/0.12 3.34/4.9 5.02/4.86 5.09/1.02 252.97
90.09%
2.55 0.98 10.20% 100% 573.70 11.87/0.24 3.27/9.82 4.96/9.72 5.01/2.04 500.07
87.17%
Rated Output Power
I
THD
Year
ATX12V
Rated Specifications
Input Voltage
Input
Watts
Load
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
Input Current
I
RMS
Test Date
Input Frequency
EU-425
Type
ID Number
Model Number
6/6/18
2018
Serial Number
Aerocool Advanced Technologies Corp.
Integrator MX 500W
N/A
Manufacturer
Output
Watts
12.11/16.98
12.15/6.79
Efficiency
12.16/3.39
PF
12.01/33.89
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the 80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient power
supplies (greater than 80% efficiency in the active mode) in technology applications.
http://www.80plus.org/
-3.0
-2.0
-1.0
0.0
1.0
2.0
3.0
-400
-300
-200
-100
0
100
200
300
400
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current
Loading...