AeroCool Integrator 600W Energy label

80 PLUS Verification and Testing Report
Value
Units
-12V
3.3V
5V*
5VSB
Fraction
TYPICAL EFFICIENCY ( 50% Load):
TYPICAL EFFICIENCY ( 50% Load):
TYPICAL EFFICIENCY ( 50% Load):TYPICAL EFFICIENCY ( 50% Load): AVERAGE EFFICIENCY :
AVERAGE EFFICIENCY :
AVERAGE EFFICIENCY :AVERAGE EFFICIENCY : 80 PLUS COMPLIANT:
80 PLUS COMPLIANT:
86.99%
86.99%
86.99%86.99%
85.50%
85.50%
85.50%85.50% YES
YES
YESYES
Ecos ID # Manufacturer Model Number Serial Number Year Type Test Date
Rated Specifications
Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz. Input AC Current Waveform (ITHD = 11.8%, 50% Load)
I
PF
RMS
A
1.25 0.98 15.70% 20%
3.10 0.97 11.80% 50%
6.34 0.99 7.07% 100%
800
700
600
500
400
300
Power (Watts)
200
100
0
20% 50% 100%
1119.1 Aerocool Advanced Technologies Corp. Integrator 600W NA 2008 ATX12V-EPS 11/10/2008
Input Voltage Input Current
Input Frequency
Rated Output Power
I
(%) Load
THD
Input Watts
Loading (% of Rated Output Power)
of Load
(%)
Input and Output Power
140.37 11.5/0.1 3.3/3.2 5/2.7 5/0.5 121.00
Light
347.05 11.6/0.1 3.3/8 5/6.7 5/1.2 301.89
Typical
722.71 11.7/0.3 3.3/16 5/13.3 5/2.3 602.00
Full
Input
Watts
Output Watts
100-240 Volts
8 Amps
50-60 Hz
600 Watts
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
12.1/7.8
12.1/19.4
12.1/38.8
Input Current and Voltage Waveforms
200 150 100
50
0
0 0.003 0.006 0.009 0.012 0.015
-50
Voltage (V)
-100
-150
-200
Time (s)
Voltage Current
Output
Watts
100%
90% 80% 70% 60% 50% 40%
Efficiency (%)
30% 20% 10%
0%
Efficiency of the Power Supply
0% 25% 50% 75% 100% 125%
Loading (% of Rated Output Power)
Efficiency
Efficiency %
15 10 5 0
-5
-10
-15
%
86.20%
86.99%
83.30%
Current (A)
These tests were conducted by a third party independent testing firm on behalf of the 80 PLUS Program. 80 PLUS is a certification program to promote highly­efficient power supplies (greater than 80% efficiency in the active mode) in technology applications. http://www.80plus.org/
Loading...