![](/html/ab/abaf/abaf14b379634574c21569aed373de3a1b8e8e7213e29697b53216e412e1956c/bg1.png)
80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
4 Amps
50-60 Hz
500 Watts
Note: All measurements were taken with input voltage at 230 V nominal at 50 Hz. Input AC Current Waveform (ITHD = 10.93%, 50% Load)
0.38 0.72 65.69% 10% 62.95 11.73/0.03 3.36/0.96 5.01/0.96 5.07/0.22 50.81 80.72%
0.57 0.90 39.78% 20% 118.88 11.79/0.05 3.35/1.93 4.99/1.92 5.05/0.44 102.01 85.81%
1.30 0.99 10.93% 50% 294.20 11.95/0.13 3.32/4.82 4.97/4.78 4.98/1.11 255.16 86.73%
2.74 0.98 14.52% 100% 619.50 12.21/0.27 3.27/9.65 4.89/9.56 4.86/2.22 512.93 82.80%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
Aerocool Advanced Technologies Corp.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-30.0
-20.0
-10.0
0.0
10.0
20.0
30.0
-400
-300
-200
-100
0
100
200
300
400
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current