![](/html/e6/e6a6/e6a68f4881fb4cd2dfb868728b044776520bb60aab4140c528d8572d6c729696/bg1.png)
80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
5 Amps
47-63 Hz
700 Watts
Note: All measurements were taken with input voltage at 230 V nominal at 50 Hz. Input AC Current Waveform (ITHD = 22.69%, 50% Load)
0.46 0.81 39.97% 10% 85.48 11.51/0.03 3.38/1.36 5.15/1.36 5.15/0.22 70.57 82.56%
0.78 0.91 29.05% 20% 162.94 11.56/0.05 3.37/2.72 5.12/2.7 5.14/0.43 141.55 86.87%
1.84 0.96 22.69% 50% 404.70 11.46/0.13 3.35/6.8 5.08/6.74 5.11/1.09 354.99 87.72%
3.80 0.97 19.61% 100% 849.90 11.24/0.26 3.32/13.62 5.02/13.46 5.06/2.17 710.98 83.65%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
Aerocool Advanced Technologies Corp.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
800
900
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-4.0
-3.0
-2.0
-1.0
0.0
1.0
2.0
3.0
4.0
-400
-300
-200
-100
0
100
200
300
400
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current