![](/html/e5/e502/e502665425af4721a225cde69ecabbe88cd3e52915a37306f9b0fb31be8319a8/bg1.png)
80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
4.5 Amps
47-63 Hz
550 Watts
Note: All measurements were taken with input voltage at 230 V nominal at 50 Hz. Input AC Current Waveform (ITHD = 12.78%, 50% Load)
0.43 0.68 63.97% 10% 68.37 11.34/0.03 3.35/1.16 5.1/1.16 5.14/0.22 54.87 80.26%
0.62 0.90 25.89% 20% 128.82 11.42/0.05 3.34/2.31 5.07/2.3 5.12/0.44 110.24 85.58%
1.42 0.97 12.78% 50% 316.50 11.35/0.13 3.32/5.78 5.04/5.73 5.07/1.09 275.78 87.13%
2.92 0.98 14.78% 100% 657.50 11.2/0.26 3.28/11.58 4.97/11.46 4.98/2.18 550.63 83.75%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
Aerocool Advanced Technologies Corp.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-3.0
-2.0
-1.0
0.0
1.0
2.0
3.0
-400
-300
-200
-100
0
100
200
300
400
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current