![](/html/4c/4cf2/4cf270f5b1d033dabbf76eff842eb446e43f81f2d8f3b14177b48b175875c990/bg1.png)
80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
4 Amps
47-63 Hz
500 Watts
Note: All measurements were taken with input voltage at 230 V nominal at 50 Hz. Input AC Current Waveform (ITHD = 11.67%, 50% Load)
0.40 0.68 52.00% 10% 62.86 11.31/0.03 3.38/1.14 5.14/1.14 5.18/0.21 50.38 80.14%
0.58 0.89 27.28% 20% 118.23 11.36/0.05 3.37/2.28 5.11/2.27 5.17/0.43 101.19 85.59%
1.29 0.97 11.67% 50% 289.60 11.23/0.13 3.35/5.69 5.07/5.64 5.13/1.07 252.83 87.30%
2.66 0.98 13.73% 100% 600.90 11.01/0.26 3.31/11.39 5.01/11.27 5.05/2.15 504.82 84.01%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
Aerocool Advanced Technologies Corp.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-3.0
-2.0
-1.0
0.0
1.0
2.0
3.0
-400
-300
-200
-100
0
100
200
300
400
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current