80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
5 Amps
47-63 Hz
700 Watts
Note: All measurements were taken with input voltage at 230 V nominal at 50 Hz. Input AC Current Waveform (ITHD = 10.03%, 50% Load)
0.42 0.83 15.11% 10% 80.45 11.52/0.02 3.4/1.3 5.08/1.3 5.12/0.21 71.15 88.44%
0.74 0.92 13.70% 20% 156.08 11.49/0.05 3.4/2.6 5.08/2.58 5.11/0.42 142.31 91.18%
1.75 0.97 10.03% 50% 391.10 11.54/0.12 3.4/6.52 5.07/6.45 5.09/1.03 355.79 90.97%
3.61 0.99 4.30% 100% 822.70 11.69/0.25 3.39/13.04 5.06/12.89 5.05/2.08 708.63 86.13%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
Aerocool Advanced Technologies Corp.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
800
900
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-3.0
-2.0
-1.0
0.0
1.0
2.0
3.0
-400
-300
-200
-100
0
100
200
300
400
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current