Aermec EWI071H / CWI071H Air Conditioner user guide manual

PLASMACLUSTER ionising filter. Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them.
Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air.
The result is in the air: you can finally breath clean, odour-free ionised air.
EWIH is fitted with a new generation filter: PLASMACLUSTER produces even more ions than the previous version. The result is faster air purification in the climate controlled environment.
EWIH is fitted with new vertical deflectors which, in addition to the standard positions used in cooling and heating mode, can also direct the air flow towards the ceiling (cooling function) or towards the floor (heating function). The result is better air distribution around the room without irritating draughts.
Split system heat pumps Wall installation with capacities from 2.1 to 7.0 kW with Inverter and Plasmacluster filter
NEW!
EWIH
• With R410A refrigerant
• Available in 5 different power versions
• Inverter technology for large power savings and optimized room comfort conditions
• Room reaches required temperature after switching on in 2/3 the time of an equivalent appliance without an inverter
• Excellent ratio between heating capacity and cooling capacity, thanks to the inverter-con­trolled compressor
• Three-speed cross flow fan
• Variable speed rotary compressor
• Air outlet deflectors with horizontal adjust-
ment facility
• Motorized louver controllable from remote handset for vertical adjustment of outlet air flow direction
• Very quiet operation
• Infrared remote handset with LCD display for full control of all functions of the appliance
• Microprocessor control
• Local control facility
• Timer for programming On/Off times
• Programs for cooling only, heating only, dehumidification and automatic operation (heating/cooling)
• Self-diagnostics function
• Easily removable, washable air filter with anti-mould treatment
• Defrost control
• Condensation control device for operation in cooling mode with an external temperature up to -10°C, standard for 071H, 091H, 121H and 181H sizes, not available for 241H
• Refrigerant lines with flared ends
• Refrigerant lines up to 15m for EWI 071H ­091H - 121H, up to 20m for EWI 181H and up to 30m for EWI 241H
Features
Aermec adheres to the EUROVENT Certification Programme. The products concerned appear in the EUROVENT Certified Products Guide.
RR441100AA
Plasmacluster
A
Energy Efficiency
EWI 071 H EWI 091 H EWI 121 H
EWI 181 H EWI 241 H
CWI H
Cod.: SEWIHUY.07 / 0709
Performance values refer to the following conditions: measured at 1.3 m in an anechoic chamber.
Cooling:
- room air temperature 27 °C D.B., 19 °C W.B.;
- ambient air temperature 35 °C; maximum speed.
Heating:
- room air temperature 20 °C;
- ambient air temp. 7 °C D.B., 6 °C W.B.; max. speed.
Power supply = 230V ~ 50Hz. (E) Eurovent certified performance values.
Indoor unit Outdoor unit
071 H 091 H 121 H 181 H 241 H 071 H 091 H 121 H 181 H 241 H
Height A 278 278 278 325 325 540 540 540 540 800 Width B 790 790 790 1040 1040 730 730 730 780 890 Depth C 198 198 198 229 229 250 250 250 265 320 Weight kg 10 10 10 16 16 36 36 36 37 61
The technical data in this document are not binding. Aermec S.p.A. reserves the right to make whatever modifications it deems necessary to improve the product at any time.
Aermec S.p.A.
Via Roma, 44 - 37040 Bevilacqua (VR) - Italy Tel. +39 04 42 63 31 11 - Telefax +39 044 29 35 66 www.aermec.com
Technical data
Dimensions (mm)
EWI 071 H EWI 091 H EWI 121 H EWI 181 H EWI 241 H CWI 071 H CWI 091 H CWI 121 H CWI 181 H CWI 241 H
2100 2640 3500 5000 7000
900 - 2500 900 - 3000 900 - 3800 900 - 5700 1600 - 7700
AAABC
3,96 3,38 3,21 3,01 2,81
530 780 1090 1660 2490
200 - 760 200 - 960 210 - 1300 330 - 2190 500 - 2900
2,5 3,7 5,0 7,4 11
0,6 0,7 1,2 1,6 2,6 480 516 588 924 1098 408 438 510 786 954 330 330 414 636 744
2400 3100 4000 5700 7500
900 - 3400 900 - 4800 1000 - 6000 900 - 7700 1800 - 9500
AAAAC
4,70 4,24 3,89 3,60 3,22
510 730 1030 1580 2330
160 - 1100 160 - 1400 180 - 1900 330 - 2400 500 - 3170
2,4 3,5 4,8 7 10,3
37 39 40 43 47 28 28 28 33 36 45 45 48 49 55
1392 1398 1602 1908 3360
1/4” 1/4” 1/4” 1/4” 3/8” 3/8” 3/8” 3/8” 1/2” 5/8”
Cooling capacity
nominal (E) W
min. - max. W Energy Efficiency EER
Input power
nominal (E) W
min. - max. W Input current nominal A Moisture removed max. speed l/h
max. m3/h Indoor unit air flow rate med. m3/h
min. m3/h
Heating capacity
nominal (E) W
min. - max. W Energy Efficiency COP
Input power
nominal (E) W
min. - max. W Input current nominal A
Indoor unit
max. dB (A)
Sound pressure min. dB (A)
Outdoor unit dB (A) Outdoor unit air flow rate m3/h
Refrigerant connections
liquid Ø
gas Ø
INDOOR UNIT
INDOOR UNIT
A
C
B
A
C
B
A
B
C
OUTDOOR UNIT