Air conditioners and split system heat pumps
Wall installation with power from 2.5 to 6.8 kW with Inverter
NEW!
GWI
RR441100AA
Features
A
Energy efficient
• Available in 4 sizes with different potentiality
• R410A refrigerant gas
• Inverter device for large energy saving and
optimisation of environment conditions
• Heat pump functioning with reverse cooling
cycle and defrost control
• 3 speed tangential fan: Minimum, Medium,
Maximum
• Variable speed rotary compressor
• Silent functioning
• Microprocessor control
• Infrared ray remote control with liquid crystal
display for checking all functions
• Possibility of emergency control (Auto/Stop
key)
• Liquid crystal display on front panel
• Timer for programming hourly functioning
(Start/Stop)
• Functioning mode: Cooling, Heating,
Dehumidification, Automatic and Fan only
• Nightmode
• Auto-restart
• Self-diagnostics function
• Air filter with easy extraction and cleaning
• Air flow louvered fins with horizontal adjustment facility
• Powered deflector louvers, which can be
activated by remote control to direct the flow
air vertically
• Refrigerant lines with flared connections
• Easy installation and maintenance
• Cooling mode with ambient temperature
down to 5°C
GWI_E
GWI_C
Code: SGWIUY.02 / 0907
The technical data given on this documentation is not binding.
Aermec S.p.A. reserves the right to apply at any time all the
modifications deemed necessary for improving the product.
Split system room air conditioners and heat pumps
Wall installation with capacities from 2.7 to 6.4 kW
NEW!
GW
Features
A
Energy Efficiency
Please consult
technical data in the
table
GW_E
GW 090 C
GW 120 C
• Available in 4 sizes with different potential
• Realised for use with R410A refrigerator gas
• Heat pump model with cooling cycle inversion and defrost control
• Four speed cross flow fan
• Rotary compressor
• Low noise operation
• Microprocessor control
• Infra Red remote control panel with LCD
display
• Local control facility
• Front Panel display
• Timer for programming hourly functioning
(Start/Stop)
• Programs: cooling, heating, dehumidifier only
and automatic
• Nightmode
• Auto-restart
• Self diagnostics function
• Easily removable air filter
• Horizontal air delivery louver
• Motor driven deflector louver worked from a
remote control for vertical delivery of output air
• Refrigerators with flared-type connections
• Easy installation and maintenance
• Additional pressure connection (1/2"UNF for
R410A) on the refrigerant circuit (only for
GW180C and GW240C), available to connect fan speed control
RR441100AA
Cod.: SGWUY.01 / 0905
The technical data in this document are not binding.
Aermec S.p.A. reserves the right to make whatever modifications
it deems necessary to improve the product at any time.
Cooling capacityW
Energy Efficiency
EER
Moisture removedl/h
Total input power W
Total input current A
Heating capacity W
Energy Efficiency
COP
Total input power W
Total input current A
m
3
/h (min)
Air flow rate (GW E)m
3
/h (med)
m
3
/h (max)
dB(A) (min)
Sound pressure (GW E)dB(A) (med)
dB(A) (max)
Air flow rate (GW C)m
3
/h
Sound pressure (GW C)dB(A)
Compressor
Lines max lengthm (total)
Max level difference
m
(Indoor - outdoor unit)
Refrigerant connections
Ø liquid
Ø gas
Refrigerant lines
Ø liquid
Ø gas
PLASMACLUSTER ionising filter.
Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them.
Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions
neutralise the gas pollutant molecules, forming products that are normally present in clean air.
The result is in the air: you can finally breath clean, odour-free ionised air.
EWIH is fitted with a new generation filter: PLASMACLUSTER produces even more ions than the previous version.
The result is faster air purification in the climate controlled environment.
The COANDA effect
EWIH is fitted with new vertical deflectors which, in addition to the standard positions used in cooling and heating mode, can also direct the air flow
towards the ceiling (cooling function) or towards the floor (heating function).
The result is better air distribution around the room without irritating draughts.
Split system heat pumps
Wall installation with capacities from 2.1 to 7.0 kW with Inverter and
Plasmacluster filter
NEW!
EWIH
• With R410A refrigerant
• Available in 5 different power versions
• Inverter technology for large power savings
and optimized room comfort conditions
• Room reaches required temperature after
switching on in 2/3 the time of an equivalent
appliance without an inverter
• Excellent ratio between heating capacity and
cooling capacity, thanks to the inverter-controlled compressor
• Three-speed cross flow fan
• Variable speed rotary compressor
• Air outlet deflectors with horizontal adjust-
ment facility
• Motorized louver controllable from remote
handset for vertical adjustment of outlet air
flow direction
• Very quiet operation
• Infrared remote handset with LCD display for
full control of all functions of the appliance
• Microprocessor control
• Local control facility
• Timer for programming On/Off times
• Programs for cooling only, heating only,
dehumidification and automatic operation
(heating/cooling)
• Self-diagnostics function
• Easily removable, washable air filter with
anti-mould treatment
• Defrost control
• Condensation control device for operation in
cooling mode with an external temperature
up to -10°C, standard for 071H, 091H, 121H
and 181H sizes, not available for 241H
• Refrigerant lines with flared ends
• Refrigerant lines up to 15m for EWI 071H 091H - 121H, up to 20m for EWI 181H and
up to 30m for EWI 241H
Features
Aermec adheres to the
EUROVENT Certification
Programme.
The products concerned
appear in the
EUROVENT Certified
Products Guide.
RR441100AA
Plasmacluster
A
Energy Efficiency
EWI 071 H
EWI 091 H
EWI 121 H
EWI 181 H
EWI 241 H
CWI H
Cod.: SEWIHUY.07 / 0709
Performance values refer to the following conditions:
measured at 1.3 m in an anechoic chamber.
Cooling:
- room air temperature 27 °C D.B., 19 °C W.B.;
- ambient air temperature 35 °C; maximum speed.
Heating:
- room air temperature 20 °C;
- ambient air temp. 7 °C D.B., 6 °C W.B.; max. speed.
The technical data in this document are not binding.
Aermec S.p.A. reserves the right to make whatever modifications
it deems necessary to improve the product at any time.
min. - max.W
Input currentnominalA
Moisture removedmax. speedl/h
max.m3/h
Indoor unit air flow ratemed.m3/h
min.m3/h
Heating capacity
nominal (E)W
min. - max.W
Energy Efficiency
COP
Input power
nominal (E)W
min. - max.W
Input currentnominalA
Indoor unit
max. dB (A)
Sound pressuremin. dB (A)
Outdoor unitdB (A)
Outdoor unit air flow ratem3/h
Refrigerant connections
liquidØ
gasØ
INDOOR UNIT
INDOOR UNIT
A
C
B
A
C
B
A
B
C
OUTDOOR UNIT
EWI 071 H
EWI 091 H
EWI 121 H
EWI 181 H
EWI 241 H
CWI 071 H
CWI 091 H
CWI 121 H
CWI 181 H
OUTDOOR UNIT
CWI 241 H
EWAH
Aermec adheres to the
EUROVENT Certification
Programme.
The products concerned
appear in the
EUROVENT Certified
Products Guide.
Split system heat pumps
Wall installation with capacities from 2.05 to 3.5 kW with Plasmacluster filter
R410AR407C
EWA_H
Plasmacluster
CSA_H
R410A
PLASMACLUSTER ionising filter.
Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them.
Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative
ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air.
The result is in the air: you can finally breath clean, odour-free ionised air.
Features
• 3 different power versions
• These versions use refrigerant gases R410A
(CSA_H) and R407C (CWX)
• Can work as a heat pump (CSA_H), reversing
the cooling cycle and controlling defrosting
• Cooling function (CWX) with water-based
condensing unit
• Heat pump models with cooling cycle inversion operation and defrost control
• Three-speed cross flow fan
• Rotary compressor
A
Energy Efficiency
• Very quiet operation
• Infrared remote handset with LCD display for
full control of all appliance functions
• Local control facility
• Microprocessor control
• Timer for hourly operation programming and
timer On LED
• Programs for cooling only, heating only, dehumidification and automatic operation
(heating/cooling)
• Self-diagnostics function
CWX
When used together with CWX this
device works only in cooling mode.
R407C
• Easily removable, washable air filter with antimould treatment
• Air outlet deflectors with horizontal adjustment
facility
• Motorized louver controllable from remote
handset for vertical adjustment of outlet air
flow direction
• Refrigerant lines with flared connections
• Refrigeration lines up to 10m for EWA 070 H
and 090 H, up to 15m for EWA 120 H
Technical data
A
B
C
A
B
C
A
B
C
Cooling capacityW
Moisture removedl/h
Total input power (CSA)W
Total input power (CWX)W
Total input current (CSA)A
Total input current (CWX)A
Water consumption at 16 °C
Heating capacity (CSA)W
Energy Efficiency
COP
Total input power (CSA)W
Total input current (CSA)A
Air flow rate (EWA)m3/h (med.)
e Sound pressure (EWA)dB(A) (med.)
Air flow rate (CSA)m3/h
ee Sound pressure (CSA)dB(A)
eee Sound pressure (CWX)dB(A)
Refrigerant connections (CSA)
Refrigeration line (CSA)
Refrigerant connections (CWX)
Refrigeration line (CWX)
l/h--160
m3/h (min.)
m3/h (max.)
dB(A) (min.)
dB(A) (max.)
Ø liquid
Ø gas
Ø liquid
Ø gas
Ø liquid
Ø gas
Ø liquid
Ø gas
EWA 070HEWA 090 HEWA 120 H
CSA 070 HCSA 090 HCSA 120 H
The technical data in this document are not binding.
Aermec S.p.A. reserves the right to make whatever modifications
it deems necessary to improve the product at any time.
Aermec adheres to the
EUROVENT Certification
Programme.
The products concerned
appear in the
EUROVENT Certified
Products Guide.
PLASMACLUSTER ionising filter.
Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them.
Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative
ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air.
The result is in the air: you can finally breath clean, odour-free ionised air.
Split system room air conditioners and heat pumps
Wall installation with capacities from 5.15 to 6.6 kW with Plasmacluster filter
EWP
• 2 different power versions
• These versions use refrigerant gases R410A
(CS_H) and R407C (CWX / CWX T)
• Can work as a heat pump (CS_H), reversing the
cooling cycle and controlling defrosting
• Cooling function (CWX / CWX T) with watercooled condensing unit
• Three-speed cross flow fan
• Rotary compressor
• Very quiet operation
• Infrared remote handset with LCD display for
full control of all appliance functions
• Local control facility
• Microprocessor control
• Timer for hourly operation programming and
timer On LED
• Night-time program
• Dehumidification program
• Self-diagnostics function
• Easily removable, washable air filter with anti-
mould treatment
• Air outlet deflectors with horizontal adjustment
facility
• Motorized louver controllable from remote
handset for vertical adjustment of outlet air
flow direction
• Refrigerant lines with flared connections
• Refrigerant lines up to 15 m in length.
Features
R410AR407C
Plasmacluster
CWX
CS H
When used together with CWX this
device works only in cooling mode.
R410A
R407C
Cod.: SEWPUY.02 / 0710
The technical data in this document are not binding.
Aermec S.p.A. reserves the right to make whatever modifications
it deems necessary to improve the product at any time.
Performance values refer to the following conditions:
e Sound pressure measured at 1.3 m in an anechoic chamber with
direction factor 4.
ee Sound pressure measured at 1 m in an anechoic chamber with
direction factor 2.
eee Sound pressure measured in an 85 m3semi-reverberant test
chamber with reverberation time Tr = 0.5s.
Cooling:
- room air temperature 27 °C D.B., 19 °C W.B.;
- ambient air temperature 35 °C; maximum speed.
Heating:
- room air temperature 20 °C;
- ambient air temp. 7 °C D.B., 6 °C W.B.; maximum speed.
Power supply= 230V ~ 50Hz; 400V 3N 50Hz (CWX T).
Technical data
Cooling capacityW
Moisture removedl/h
Total input power (CS H)W
Total input power (CWX)W
Total input power (CWX T)W
Total input current (CS H)A
Total input current (CWX)A
Total input current (CWX T)A
Water consumption at 16 °C (CWX/T) l/h
Heating capacity (CS H)W
Total input power (CS H)W
Total input current (CS H)A
* = Apply the fitting (1/2"F - 5/8"M) supplied with the CWX 2417 /T condensing unit to the EWP unit gas refrigerant connections
EFI
Aermec adheres to the
EUROVENT Certification
Programme.
The products concerned
appear in the
EUROVENT Certified
Products Guide.
Split system heat pumps
Universal installation with capacities from 2.1 to 7 kW with Inverter and Plasmacluster filter
R410A
A
Energy Efficiency
Plasmacluster
PLASMACLUSTER ionising filter.
Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them.
Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions
neutralise the gas pollutant molecules, forming products that are normally present in clean air.
The result is in the air: you can finally breath clean, odour-free ionised air.
Features
• Available in 5 different power versions
• Inverter technology for large power savings and
optimized room comfort conditions
• Room reaches required temperature after switching on in 2/3 the time of an equivalent
appliance without an inverter
• Excellent ratio between heating capacity and
cooling capacity, thanks to the inverter-controlled compressor
• Can be installed in vertical or horizontal positions
• Variable speed rotary compressor
Accessories
• DCPX: Low temperature device for operation
of outdoor units below 20 °C.
• Condensation control device for operation in
cooling mode with an external temperature
up to -10°C, standard for 091H, 121H, 181H
and 241H
• Air outlet deflectors with horizontal adjustment
facility
• Motorized louver controllable from remote
handset for vertical adjustment of outlet air
flow direction
The technical data in this document are not binding.
Aermec S.p.A. reserves the right to make whatever modifications
it deems necessary to improve the product at any time.
Air conditioners and split system heat pumps
Monosplit with capacities from 2.5 to 16 kW
LC
• The LC range is made up from outdoor units
that can be coupled with 3 types of indoor
unit
Outdoor unit selected from:
• LC 5 sizes with different power with single
phase power supply
• LC T 4 sizes with different power with three
phase power supply
Indoor unit selected from:
• LC C Cassette, suspended ceiling installation,
with remote control and wired control panel:
LC 035C - 050C - 070C - 100C -120C - 140C
(coupling with the MDSGL40 or MDSGL40S
accessory is mandatory)
• LC F Floor Ceiling, wall and/or ceiling instal-
lation, with remote control and wired control
panel:
LC 025F - 035F - 050F - 070F - 100F -120F 140F
• LC D ducted, ducted installation
with remote control and wired control panel:
• Heat pump functioning with reverse cooling
cycle and defrost control
• Outdoor unit with rotary or Scroll compressor
• Indoor unit with 3 speed fan unit
• Infrared ray remote control with liquid crystal
display for checking all functions
• Liquid crystal display wired control panel for
checking all functions
• Microprocessor control
• Possibility to set the room temperature probe
in intake of the indoor unit or in the wired
control panel
• Timer for programming switch-off or switchon
• Functioning mode: Cooling, Heating,
Dehumidification, Automatic and Fan only
• Maximum silence
• Condensate drain pump on the LC C version
• Easy installation and maintenance
• Air filter with easy extraction and cleaning
• Refrigerant lines with flared connections
• Maximum length of the refrigerant lines up to
20m for the LC25, LC35 and LC50 units; up
to 30m for the LC70 units; up to 50m for the
LC100, LC100T, LC120T, LC140T and
LC160T units
• Condensate control device for functioning in
cooling mode with external temperature to -7°C,
as per standard
(840x840). The flow louvers are powered.
Equipped with infrared receiver and emergency functioning key.
It is a mandatory accessory as the LC C units
are delivered without.
• MDSGL40S: Air flow and recovery grid
(600x600). The flow louvers are powered.
Equipped with infrared receiver and emergency functioning key.
It is a mandatory accessory as the LC C units
are delivered without.
Outdoor unit electric power supply = 230V~50Hz (LC) ; 400V 3N~50Hz (LC T)
Indoor unit electric power supply = 230V~50Hz (LC D)
The performance refers to the following conditions:
Sound pressure measures in a semianechoic chamber at 1m from
the front
Cooling:
- Room air temperature 27 °C D.B.; 19 °C W.B.
- External air temperature 35 °C
- Maximum speed
- Refrigerant lines length 5m
Heating:
- Room air temperature 20 °C
- External air temperature 7 °C D.B.; 6 °C W.B.
- Maximum speed
- Refrigerant lines length 5m
Outdoor unit
Indoor unit
Cooling capacityW
EER
Total input powerW
Total absorptionA
Heating capacityW
COP
Total input powerW
Total absorptionA
Compressor
Fans (external unit).n°
Air flow rate (indoor unit)m