Page 1

aërQ Temperature and Humidity Sensor
ZWA039
Aeotec aërQ Temperature and Humidity Sensor was developed to record ambient values for
humidity and temperature to warn of environment that is ideal for mould growth via Z-Wave
communication. It is powered by Aeotec Gen7 technology. The technical specifications of aërQ
Temperature and Humidity Sensor can be viewed at that link.
Before purchasing make sure to contact your Z-Wave Gateway/Controller manufacturer to
determine if this device is compatible, typically most Z-Wave gateways will be generically
compatible to Switch and Sensor type devices. You can find a list of known compatible
Gateway/Controllers in this link.
Familiarize yourself with your aërQ Sensor.
Page 2

Package Contents
Initiates Device Reset Locally. The Green LED will flash
once every seconds for 5 seconds.
Success: If ending LED is green after 10 seconds, the
factory reset was a success.
Failure: If ending LED is red after 10 seconds, the
factory reset was a failure.
Ideal Mould
environment
sense and
Wakeup Report.
Ideal Mould Environment sense: Force an immediate
measurement of the environment and change
indication based on the danger level from temperature
and humidity levels. If humidity levels are high enough,
the aërQ sensor will report Binary Sensor Report to
indicate that.
Wakeup Report: A Wakeup Report will be sent to the
Z-Wave controller/hub to allow queued commands to
be sent to aërQ sensor.
If using selective reporting, temperature and humidity
will update using the threshold levels.
Used to pair or unpair the aërQ Temperature and
Humidity Sensor.
1x aërQ Temperature and Humidity Sensor
1x Battery typ CR2477H 3V
1x Paper guide
1x Double-sided Tape.
Button Functions.
The Environment Sensor must support the following button functions.
Page 3

Quick Start.
Getting your aërQ Sensor up and running is as simple as installing it and linking it to your
Z-Wave network. The following instructions tell you how to add your aërQ Sensor to your
Z-Wave network using an existing gateway.
How to open aërQ Sensor.
There are 2 small indented arrows on the side of your aërQ Sensor that indicate where you
need to push in in order to open up aerQ Sensor.
1. Find the 2 indented arrows along the side of your aerQ Sensor.
2. Place your thumb and index finger on the 2 indented arrows and push in.
▪ If attached to a wall - pull the aerQ sensor which will separate it from the
bottom hald.
▪ If not attached to a wall - use your other hand to grip the bottom half of the
sensor and pull the 2 sides apart, the 2 halfs will split apart.
Remove the battery tab.
aërQ Sensor has a battery tab in this unit to keep the unit from utilizing the battery when it
is first purchased. Make sure that you remove this tab before you continue with the
installation.
1. Open up the aërQ Sensor to expose the battery.
▪ Locate the indented arrows and grip the top and bottom half and pull them
apart.
2. Remove the battery and the battery block tab from the unit.
3. Recycle or trash the battery block tab.
4. Replace the battery back into its hardware with + side facing outwards.
Installation of aërQ Sensor.
aërQ Sensor utilizes double-sided adhesive tape to allow you to mount aërQ Sensor onto
any flat surface.
1. Place the double-sided adhesive on the bottom of aërQ Sensor
2. Choose a place to stick aërQ Sensor and firmly press down to finish the mounting
installation.
3. Remove aërQ Sensor from its mount to prepare aërQ Sensor for pairing.
Page 4

Using an existing gateway.
SmartStart Inclusion.
You can use this method of inclusion only if your Z-Wave gateway/controller/hub
supports SmartStart.
1. Open up your Z-Wave gateway/controller/hub interface.
2. Select SmartStart inclusion. (Please refer to your controller/gateway manual on
how to do this).
3. Scan the QR code located on the aërQ Sensor.
4. Within 10 minutes after powering your aërQ Sensor, it will automatically get
included into your Z-Wave gateway/controller/hub.
Classic Inclusion
Use this method if SmartStart is not supported by your Z-Wave
gateway/controller/hub.
1. Place your gateway or controller into Z-Wave pair or inclusion mode. (Please
refer to your controller/gateway manual on how to do this).
2. Tap the Tamper Switch on aërQ Sensor 3x times within 1 second.
3. Your gateway should confirm if aërQ Sensor is successfully included into your
network.
4. Place the aërQ Sensor on the mounting base.
Page 5

Product Usage.
This device will start monitoring all air parameters once paired to your Z-Wave network. The
measurement of air happens once every 15 minutes, while tapping the Tamper Switch once
will force an immediate measurement and change indication based on the danger level.
LED Indicators.
aërQ Sensors LED indications when powered and in use.
When Unpaired.
Red and Green LED blink every second - Entered pairing process (you may not see this
if gateway and aërQ Sensor sync quickly together)
Solid Green LED for 1.5 seconds - successful pair.
Solid Red LED for 1.5 seconds - failed pair upon timeout.
When Paired.
Green LED - Environment is good.
Red LED - Environment is ideal for mould growth.
Red blinks 3 times, Green blinks once - Low battery.
Reported Sensors.
Humidity: +/- 3 % on relative humidity, +/-1 %
Hysteresis Temperature: 0 ... 65 °C +/- 1 Kelvin
Dew Point: 0 ... 65 °C +/- 1 Kelvin (calculated from other sensor values)
Page 6

Wireless Reports and Command Class.
The measured values of Humidity and Temperature are reported to your Z-Wave gateway,
below are the primary command class used to report the sensor values.
Main Command Classes and Descriptions.
Each command class will output specific values to your Z-Wave gateway, below is a
brief sliver of information that should be displayed in your controller if it is supported.
Binary Sensor V2
Reports ON / 0xFF if humidity is greater than 70%.
Reports OFF / 0x00 if humidity is less than 70%.
Multilevel Sensor V11
Air temperature
Scale = Celcius
Precision = 1
Size = 2
Humidity
Scale = Percentage
Precision = 0
Size = 2
Dew Point
Scale = Celcius
Precision = 1
Size = 2
Page 7

Advanced functions.
Communication with a Sleeping device (Wakeup).
This device is battery operated and utilizes a deep sleep state most of the time to save battery
life. Communication with the device is limited. In order to communicate with the aërQ Sensor,
a Z-Wave controller is needed in the network.
This device will wakeup regularly and report a wakeup state by sending out a Wakeup Report.
The controller can then send out queued commands for the aërQ Sensor to control it before it
goes back to sleep.
If the device was included by a Z-Wave controller, the controller will usually perform all
necessary configurations. The wakeup interval is a trade-off between maximal battery lifetime
and the desired responses of the device.
Steps to Wakeup aërQ Sensor:
1. Unlatch aërQ Sensor from its mounting base.
2. Tap the button once to wakeup aërQ Sensor.
Removing your aërQ Sensor from a Z-Wave network.
aërQ Sensor can be removed from your Z-Wave network at any time. You’ll need to use an
existing Z-Wave network to do this and the following instructions which will tell you how to do
this using your existing Z-Wave Network.
This method can be used with any Primary Z-Wave Controller even if it is not directly paired to
aërQ Sensor.
Using an existing gateway.
1. Place your gateway or controller into Z-Wave unpair or exclusion mode. (Please refer to
your controller/gateway manual on how to do this)
2. Tap the button on aërQ Sensor 3x times within 1 second.
3. Your gateway should confirm if aërQ Sensor is successfully excluded from your
network.
The LED of aërQ Sensor will blink its red LED once per a second to confirm it is ready
to be paired again.
Page 8

Manually Factory reset aërQ Sensor.
This device also allows being reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable otherwise your
controller will be left with a phantom node that does not exist.
1. Push the button of aërQ Sensor for 20 seconds.
Association Groups.
Group Association is a specific function in Z-Wave that allows you to tell aërQ Sensor who it
can speak to. Some devices may only have 1 group association meant for the gateway, or
multiple group associations that can be used for specific events. This type of function isn't
used too often, but when it is available, you may be able to use it to directly communicate to
Z-Wave devices instead of controlling a scene within a gateway which can have unforeseen
delays.
Some gateways have the ability to set Group Associations to devices that have these special
events and functions. Typically this is used to allow your gateway to update the status of aërQ
Sensor instantly.
By default, your primary gateway should have been associated with aërQ Sensor
automatically during the pairing of your Siren. For any case you have a Secondary Z-Wave
Controller, you'll need to associate it to your aërQ Sensor in order for your secondary
controller to update its status.
Page 9

Configuration Parameters.
Parameter 1: Minimum Temperature change to report.
This value defines the minimum change of temperature to cause an unsolicited report of
humidity to the central controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the temperature
changes. However, periodic reports, managed by configuration parameter 4, may still be
active.
Temperature is checked once every 15 minutes to determine if it should be reported based on
this setting.
Size: 1 Byte, Default Value: 20
Parameter 2: Minimum humidity change to report.
This value defines the minimum change of humidity to cause an unsolicited report of humidity
to the central controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the humidity
changes.
However, periodic reports, managed by configuration parameter 4, may still be active.
Humidity is checked once every 15 minutes to determine if it should be reported based on this
setting.
Size: 1 Byte, Default Value: 7
Parameter 4: Periodic Reports.
This parameter defines the time interval to send an unsolicited report.
If the value is set to 0, there will be no periodic reports sent to the controller.
However, reports on temperature/humidity changes, managed by configuration parameters 1
and 2, may still be active.
Size: 2 Byte, Default Value: 43200
Page 10

Parameter 5: Temperature Upper Watermark value.
This parameter defines a temperature.
If the measured temperature surpasses this watermark a BASIC command is sent into
Association Group 2.
The value of BASIC SET is defined by parameter 10.
Size: 2 Byte, Default Value: 0
Parameter 6: Temperature Lower Watermark value.
This parameter defines a temperature.
If the measured temperature dropps below this watermark a BASIC command is sent into
Association Group 3.
The value of BASIC SET is defined by parameter 9.
Size: 2 Byte, Default Value:
Parameter 7: Humidity Upper Watermark value.
This parameter defines the relative humidity.
If the measured relative humidity surpasses this watermark a BASIC command is sent into
Association Group 4.
The value of BASIC SET is defined by parameter 12.
Size: 1 Byte, Default Value: 0
Parameter 8: Humidity Lower Watermark value.
This parameter defines a relative humidity.
If the measured temperature drops below this relative humidity a BASIC command is sent into
Association Group 5.
The value of BASIC SET is defined by parameter 11.
Size: 1 Byte, Default Value:
Page 11

Parameter 9: Low Temperature Trigger BASIC Set Command Value.
This defines what BASIC SET command value shall be sent out into association group 3.
Value meaning:
255 = ON.
0 = OFF.
1 - 100 = Defines a level between 0 - 100% if controlling dimmers.
Size: 1 Byte, Default Value: 255
Parameter 10: High Temperature Trigger BASIC Set Command Value
This defines what BASIC SET command value be sent out into association group 2.
Value meaning:
255 = ON.
0 = OFF.
1 - 100 = Defines a level between 0 - 100% if controlling dimmers.
Size: 1 Byte, Default Value: 0
Parameter 11: Low Humidity Trigger BASIC Set Command Value.
This defines what BASIC SET command value shall be sent out into association group 5.
Value meaning:
255 = ON.
0 = OFF.
1 - 100 = Defines a level between 0 - 100% if controlling dimmers.
Size: 1 Byte, Default Value: 255
Parameter 12: High Humidity Trigger BASIC Set Command Value.
This defines what BASIC SET command value shall be sent out into association group 4.
Value meaning:
255 = ON.
0 = OFF.
1 - 100 = Defines a level between 0 - 100% if controlling dimmers.
Size: 1 Byte, Default Value: 0
Page 12

Parameter 13: Offset value for Mould environment notification
Reset all Parameter settings to their default settings.
Completely factory reset sensor and send device
reset locally notification.
This value allows to increase the humidity threshold for ideal mould environment notification
by max 10%. (default 0 value will set to trigger at humidity levels above 70%)
Size: 1 Byte, Default Value: 0
Parameter 64: Temperature Scale
This parameter sets the temperature scale.
Size: 1 Byte, Default Value: 1
Parameter 255: Reset Parameter
This parameter helps reset configuration parameters and the device to factory defaults.
Size: 4 Byte, Default Value: 0