Aeotec ZWA037 User Manual

Page 1
(ZWA037-A)
Page 2
1
Command Class Name
Version
Required Security Class
Supervision
V1
none
Association
Group
Information
V3
highest
granted
Device Reset
Locally
V1
highest
granted
Firmware
Update
Meta
Data
V5
highest
granted
Engineering Specifications
This product can be operated in any Z-Wave™ network with other Z-Wave Plus™ certified devices from other
manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to
increase reliability of the network. Each module is designed to act as a repeater, which will re-transmit a radio
frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received
at its intended destination. ZWA037-A is a security enabled Z-Wave Plus™ device. A security Enabled Z-Wave Plus™
Controller must be used in order to fully utilize the product.
1 Library and Command Classes
1.1 Embedded SDK
v 7.13.9
1.2 Device Type
Generic Type: Switch Multilevel
Specific Type: Not Used
1.3 Role Type
Always On Slave (AOS): ROLE_TYPE_SLAVE_ALWAYS_ON (0x05)
1.4 Command Class
Z-Wave Plus Info V2 none
Security 2 V1 none
Transport Service V2 none
Association V3 highest granted
Multi-Channel Association V4 highest granted
Version V3 highest granted
Manufacturer Specific V2 highest granted
Power Level V1 highest granted
Indicator V3 highest granted
Configuration V4 highest granted
Central Scene V3 highest granted
Page 3
2
Switch Multilevel V4 highest granted
Scene Activation V1 highest granted
Scene Actuator Configuration V1 highest granted
2 Installation wiring diagram
2.1 Single pole wiring
2.2 3-Way wiring
Page 4
3
2.3 4-Way wiring
Functions
Action Button
Description
3 Z-Wave™ Network Operation
Out of
Inclusion 1x tap
Central Scene 2x tap In network
Exclusion 3x tap
network
In network
In network
Out of
network
Send NIF for network pairing/ inclusion (white LED quick flashes).
If pairing is successful, the LED will turn to solid green for 2s, then
deactivates.
Trigger to send Central Scene 1x tap scene.
ON/OFF control of output load.
Trigger to send Central Scene 2x tap scene.
Send NIF for network unpairing/ exclusion (purple LED flashes).
Trigger to send Central Scene 3x tap scene.
Page 5
4
Toggle parameter 86 4x tap
Toggle parameter 84 5x tap
Toggles parameter 86 from value 0 - 100%.
Toggles parameter 84 from value 0 - 9.
Toggle parameter 85 6x tap
Toggle parameter 83 7x tap
8x tap +
Set the max brightness
level
Toggle parameter 110 9x tap
Toggle parameter 121 4x tap
Toggle parameter 122 5x tap
Toggle parameter 20 6x tap
Set the min brightness
level
Toggle parameter 111 9x tap
Toggle parameter 120 10x tap
hold on
8th, then
release.
8x tap +
hold on
8th, then
release.
Top
button
Bottom
button
Toggles parameter 85 from value 0 - 9
Toggles Parameter 83 from values 0, 1, 2.
Sets the default max brightness level on Parameter 132, when
released, saves set brightness as the max brightness level.
Starts ramp up from current output level.
Ramps speed at 5 seconds to 100%
Toggle parameter 110 from value 0, 1, 2
Toggle parameter 121 from value 0, 1, 2, 3.
Toggle parameter 122 from value 0, 1, 2.
Toggle parameter 20 from value 0, 1, 2
Sets the default minimum brightness level on Parameter 131,
when released, saves set brightness as the minimum brightness
level.
Starts ramp down from current output level.
Ramps speed at 5 seconds to 100%.
Toggle parameter 111 from value 0, 1, 2
Toggle parameter 120 from value 0, 1, 2
Central Scene
Central Scene Release
Nothing
Factory reset Press and hold for 20s
1) This device must be used in conjunction with a Security 2 Enabled Z-Wave Controller in order to fully utilize all
implemented functions.
Press and hold for 1 -
15s
Press and hold for 16
– 19s
Trigger to send Central Scene hold scene.
Dim control output load.
Trigger to send Central Scene release scene.
Stop dim control output load.
Flash red LED rapidly.
Manual Factory reset -> Send gateway RESET DEVICE LOCALLY
Note: When the LED turns into Blue, then release the button, the
LED will be solid Blue for 2 seconds, during the 2 seconds, tap
the button again, it will start the factory reset process, then return
to factory reset LED status.
3 Association Groups
The device supports 9 association groups and every group supports max 5 associated nodes.
Group 1 is lifeline group, all nodes associated in this group will receive the messages sent by device through lifeline.
Group 2-9 are controlling groups.
The Command Class supported by each association group is shown in the table below:
Page 6
5
ID Name
Node Count
Profile
Function
1 Lifeline 5
Device Reset Locally Notification:
Basic Set or Switch Binary Set:
Switch Multilevel Set:
Basic Set or Switch
Binary Set
:
Basic Set or Switch Binary Set
:
bottom button
Basic Set or Switch Binary Set
:
bottom button
Indicator ID
Property ID
0x50 (NODE IDENTIFY)
0x03(ON OFF PERIOD)
General:
Lifeline
Issued when Factory Reset is performed.
Indicator Report:
Issued when included successfully.
Switch Multilevel Report:
Issued when output level is changed. (Determined by Parameter 80).
Basic Report:
Issued when output level is changed (Determined by Parameter80).
Central Scene Notification:
Issued when button press or hold or release. (Determined by Parameter
121).
Top button
2
set ON/OFF
Top button
3
multilevel set
4
button set
5
multilevel set
6
switch set
7
multilevel set
8
set ON/OFF
9
set multilevel
Bottom
ON/OFF
Bottom
button
External
ON/OFF
External
switch
Top and
Top and
set
5
5
5
5
5
5
5
5
Control:
Key 1
Control:
Key 1
Control:
Key 2
Control:
Key 2
Control:
Key 3
Control:
Key 3
Control:
Key 4
Control:
Key 4
Issued when Top button press. (The command class is determined by
Parameter 82)
Issued when Top button press or hold and release.
Issued when Bottom button press. (The command class is determined
by Parameter 82)
Switch Multilevel Set:
Issued when Bottom button press or hold and release.
Issued when External Switch press. (The command class is determined
by Parameter 82).
Switch Multilevel Set:
Issued when External Switch press or hold and release.
Issued when Top/ Bottom button press. (The command class is
determined by Parameter 82).
Switch Multilevel Set:
Issued when Top/Bottom button press or hold and release.
4 Basic Command Map
Basic CC is mapped to Switch Multilevel CC.
Basic Set is mapped to Switch Multilevel Set.
5 Indicator Command Class
Page 7
6
Parameter
Value
Number
Name
Information
Size MIN MAX Default
Description
20 Power
Status after power
1 0 2 2 0 -
return to OFF
40 Auto Turn Off
Timer that auto turn off
4 0 65535
0 0 - disabled
41 Auto Turn On
Timer that auto turn on
4 0 65535
0 0 - disabled
80 Instant
The command for
1 0 2 2 0 -
Nothing
82 Association
Setting command for
1 1 2 1 1 -
Basic Set
83 Led Indicator
Select the indicator
1 0 2 2 0 -
disable completely
84 Led Indicator
Select the indicator
1 0 9 9 0 -
Disabled
85 Led Indicator
Select the indicator
1 0 9 2 0 -
Disabled
0x50 (NODE IDENTIFY) 0x04(ON OFF CYCLES)
0x50 (NODE IDENTIFY) 0x05(ONE TIME ON OFF PERIOD)
6 Manufacturer Information
Manufacturer ID 1 0x03
Manufacturer ID 2 0x71
Product Type ID 1 0x01
Product Type ID 2 0x03
Product ID 1 0x00
Product ID 2 0x25
7 Configuration
User can change the default settings by the below configuration parameters. After device reset, all these parameters
will be set to their default values.
Restore
Timer
Timer
Status
Report
Control
Settings
Settings
Color For Output
failure.
once turned on.
once turned off.
status report.
association group.
function for output.
color for output.
1 - return to ON
2 - returns to last known state when repowered
1 - Auto turn off after 1s once turned on
...
65535 - Auto turn off after 65535s once turned on
1 - Auto turn on after 1s once turned off
...
65535 - Auto turn on after 65535s once turned off
1 - Basic Report
2 - Binary Switch Report
2- Binary Switch SET
1 - Momentary blink
2 - LED follows status of output
1 - Red 2 - Blue
3- Green
4- Pink
5- Cyan
6- Purple
7- Orange
8- Yellow
9- White
Color For
color for scene.
1 - Red
Page 8
7
Scene
2 - Blue
86 Led
Setting the brightness
1 0 100 60 0 -
Disable
110 Single Tap
Select behavior when
1 0 3 0 0 -
Last brightness level
111 Double Tap
Select behavior when
1 0 3 0 0 -
Full brightness at 99
119 External
Enable or disable the
1 0 1 1 0 -
Disable
120 External
Select the external
(3-
1 0 3 1 0 -
toggle on or off only
momentary switch / 1x to toggle / 2x user Param 132
121 Output
Enable or disable
1 0 3 3 0 -
disable completely
122 Button
Select the paddle
1 0 2 0 0 -
up/ON, down/OFF
123 Report
Select behavior for
1 0 1 0 0 -
report on/off status and change LED indicator when
125 Ramp Rate
Setting ramp rate
1 0 99 2 0 -
instant...
126 Ramp Rate
for press and
Setting ramp rate
1 1 99 4 1 -
Ramp Rate 1s
131 Minimum
Setting the minimum
1 0 99 0 0 -
Disable
3- Green
4- Pink
5- Cyan
6- Purple
7- Orange
8- Yellow
9- White
Brightness
behavior
behavior
Switch
Scene
Switch Type
of indicator.
single tap.
double tap.
scene function of
external(3-way) switch.
way) switch's type.
1 - 1%
...
60 - 60% ...
100 - 100%
1- Custom value from Param 133 2- Max brightness from Param 132
3- Full brightness at 100%
... 1- Custom value from Param 133
2- Max brightness from Param 132
3- disabled
1 - enable
1 - toggle switch/1x to toggle /2x use Param 132 or 133 /3x toggle dimmer loop ramp -> toggle once more to
stop dim
2 -
or 133/ Press and hold to dim up and down
3 - momentary switch / 1x quick toggle / 2x user Param
132 or 133 / Press and hold to dim up and down (but
after a double click to full brightness, then press and
hold will always go down instead of increasing)
Control
Function
Behavior
for Tap and
Hub control
hold
most dim
output.
button functions.
report and indicator
when output is disable.
when tap to on off or
controlled by HUB.
when press and hold
the paddle.
value of dimmer.
1 - enable local control
2 - enable central scene
3 - enable local and central scene
1 - down/ON, up/OFF
2 - toggle (up or down are the same)
parameter 121 is set to 0 or 2
1 - Don't report on/off status is pressed and parameter
121 is set to 0 or 2
2 - Ramp Rate 2s
...
99 - Ramp Rate 99s
...
4 - Ramp Rate 4s
...
99 - Ramp Rate 99s
1 - Minimum value is 1
Page 9
8
setting
...
132 Maximum
Setting the
maximum
1 0 100 100 0 -
Disable
133 Custom
Setting user custom
1 0 99 0 0 -
Disable
99 - Minimum value is 99
most dim
setting
brightness
value of dimmer.
brightness.
1 - Maximum value is 1
...
100 - Maximum value is 100
1 - custom brightness level is 1
...
99 - custom brightness level is 99
8 Security Network
This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to
communicate to other security enabled Z-Wave Plus products.
This device supports security levels are listed in below table:
Security Levels
SECURITY_KEY_S0 No
SECURITY_KEY_S2_UNAUTHENTICATED Yes
SECURITY_KEY_S2_AUTHENTICATED Yes
Support (Yes/No)
9 SmartStart
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the
product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be
added automatically within 10 minutes of being switched on in the network vicinity. You can find the QR code on the
bottom of the product, like this:
And the DSK information will be shown like this:
DSK: XXXXX-XXXXX-XXXXX-XXXXX-XXXXX-XXXXX-XXXXX-XXXXX
10 Specifications
Power Supply AC120V, 60Hz
Max load 150W LED/CFL, 500W incandescent.
Min load 5W LED
Communication Frequency 908.40MHz, 916.00MHz (US)
Communication Range Up to 70m+ indoors (line of sight) or 150m outdoors.
Communication Certification Z-Wave Plus v2 with SmartStart
Page 10
9
Operational Temperature
Operating Humidity 8% to 80%
0 - 40 / 32 - 104
Loading...