Aeotec ZWA024 User Manual

Page 1
Rev. 0.6
MultiSensor 7
ZWA024
Page 2
Rev. 0.6
Engineering Specifications
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
1 Library and Command Classes
1.1 Embedded SDK
v7.12.2
1.2 Device Type
Generic Device Class: GENERIC_TYPE_SENSOR_NOTIFICATION (0x07) Specific Device Class: SPECIFIC_TYPE_NOTIFICATION_SENSOR (0x01)
1.3 Role Type
Reporting Sleeping Slave (RSS): ROLE_TYPE_SLAVE_SLEEPING_REPORTING (0x06)
1.4 Command Class
Command Class Version
Z-Wave Plus Info 2 Support Support Support
Association 2 Support Support Support
Association Group Information 3 Support Support Support
Multi Channel Association 3 Support Support Support
Battery 1 Support Support Support
Binary Sensor 2 Support Support Support
Multilevel Sensor 11 Support Support Support
Notification 8 Support Support Support
Not
added
Non- secure added
Securely added
Non-secure CC Secure CC
Application Status 1 Support Support Support
Configuration 4 Support Support Support
Transport Service 2 Support Support Support
1
Page 3
Version 3 Support Support Support
Wakeup 2 Support Support Support
Manufacturer Specific 2 Support Support Support
Device Reset Locally 1 Support Support Support
Indicator 3 Support Support Support
Powerlevel 1 Support Support Support
Security 0/2 1 Support Support Support
Supervision 1 Support Support Support
Firmware Update Meta Data 5 Support Support Support
2 Z-Wave™ Network Operation
Rev. 0.6
Functions Action
Button
1
Add
Remove
Wakeup Notify Hold for 2~5s
1
Tap one time
Tap one time
Description
Add this device into an existing Z-Wave network:
1. Power on the device, the power led will blink blue slowly.
2. Let the Primary Controller into inclusion mode (If you don’t know how to do this, refer to its manual)
3. Press the action button one time, when the yellow led on release the button. It indicates the device has enter learn mode.
4. If added successful, the power led will flash (white -> green -> white - > green at a rate of 250ms per each color) for 2 seconds.
Remove this device from an existing Z-Wave network:
1. Power on the device.
1. Let the Primary Controller into exclusion mode (If you don’t know how to do this refer to its manual)
2. Press the action button one time, when the purple led on release the button. It indicates the device has enter learn mode. If removed successful, the blue led will blink slowly.
1. Power on and make sure the device has been included into Z-Wave network.
2. Press and hold the button at least 2s until Red Led Is On and then release the button, device will send wake up notification to controller if device is in a Z-Wave network.
2
Page 4
Enter 5 minutes wakeup state:
1. Power on and make sure the device has been included into Z-Wave network.
2. Press and hold button for 5 seconds, when orange led on release it. If 5 Minutes Wakup State
RF Quality Test Hold for 9~15s
Factory Reset Hold for 15~20s
1) This device must be used in conjunction with a Security Enabled Z-Wave Controller in order to fully utilize all implemented functions.
Hold for 5~9s
orange led keep on, it indicates state entered. Exit 5 minutes wakeup state:
1. Power on and make sure the device has been included into Z-Wave
network.
2. Press and hold button for 5 seconds, when orange led on release it. If
led off, it indicates state exited.
1. Power on the device and make sure it has been included into the Z-
Wave network.
2. Press and hold the button for 9 seconds, when the cyan led on release
the button. Then, it will enter the power level test mode. At this mode, the Hot Water Switch device will send 100 frames to remote device to diagnostic network quality.
3. After the test, if >= 97 frames receive ACK, the green led will turn on 2
seconds. This indicates the network is Good.
4. If >=90 frames receive ACK, the yellow led will turn on 2 seconds. This
indicates the network is OK.
5. If < 90 frames receive ACK, the red led will turn on 2 seconds. This
indicates the network is Bad.
1. Make sure the device has been powered.
2. Press and hold the button for 15 seconds. When the red led flash, the
device will enter factory reset mode.
3. If reset successful, the blue led will blink slowly.
Rev. 0.6
3 Button Action and LED Indicator
Unit: second
Action Press down Action
Button
Tap 1 time [0.04, 1) Solid yellow status
Release Action Button
Turns on a solid yellow status, If a new node id is assigned to this device, the yellow LED will keep solid until whole network processing is complete (or entering. If successful, the LED will flash white -> green -> white - > green (at a rate of 250ms per each color change) for 2 seconds. After 2 seconds have finished, use typical paired status LED indicators for ON/OFF status from parameter #1.
3
Page 5
Rev. 0.6
Tap 2 times [0.04, 1)
Tap 4 times [0.04, 2) N/A
Press and hold [1, 2) Turn LED off
Press and hold [2, 5) Solid orange status
Press and hold [5, 9) Solid cyan status See power level test mode.
Press and hold [9, 15) Solid red status N/A
Press and hold [15, 20)
Press and hold [20, ∞) N/A N/A
Purple LED keeps on for 2 seconds and then off
Red color will blink on and off at a rate of 200ms for 2 seconds and then pulse blue color if removed
If exclusion is successful, the LED should pulse blue color slowly.
If parameter 32 is set to 2, this will be used to cancel the alarm. See parameter 30,31,32 for more information.
LED revert back to LED state based on network state. If parameter 32 is set to 4, this will be used to cancel the
alarm. See parameter 30,31,32 for more information.
Reset to factory default
4 Association Groups
The device supports 11 association groups and every group supports max 5 associated nodes. Group 1 is lifeline group, all nodes which associated in this group will receive the messages sent by device through lifeline.
When Basic CC/Switch Binary CC are used to control this device or sent through association groups to control other associated nodes, the variable will be phased as the follow ways: 0x01~0x063/0xff means On, 0x00 means Off, other values will be ignored.
The Command Class supported by each association group is shown in the table below:
Root Device
ID Name N
Profile Description o d e s
Device Reset Locally:
1 Lifeline 5 General: Lifeline
When factory reset.
Notification Report:
See Notification Chapter for more information.
4
Page 6
2 Motion 5 General: NA
by
by
Sensor Binary Report:
See Param5 for more information.
Sensor Multilevel Report:
When sensors above over limit or below under limit.
Battery Report:
See Param101.
Indicator Report:
Issued when the indicator light changed.
Basic Set:
Basic Set Command will be sent to the associated device when motion trigger or untrigger. The basic set value is determined
by Param11, Param12. See Param13 for more information.
Rev. 0.6
3 OverHeat 5 Sensor:Temperature
4 UnderHeat 5 Sensor:Temperature
5 OverHumidity 5 Sensor:Humidity
6 UnderHumidity 5 Sensor:Humidity
7 OverLight 5 Sensor:Illuminance
8 UnderLight 5 Sensor:Illuminance
Basic Set:
When the temperature change value is over or under the threshold set by Param16. Scale is determined by Param64.
Basic Set:
When the temperature change value is under or over the threshold set by Param17. Scale is determined by Param64.
Basic Set:
When the current humidity is over or under the threshold set by Param14.
Basic Set:
When the current humidity is under or over the threshold set by Param15.
Basic Set:
When the current light/lux is over or under the threshold set
Param18.
Basic Set:
When the current light/lux is under or over the threshold set
Param19.
9 OverUV 5 Sensor:Ultraviolet
10 UnderUV 5 Sensor:Ultraviolet
11 Temperature 5 Sensor:Temperature
5 Basic Command Map
Basic Set:
When the current UV is over or under the threshold set by
Param20.
Basic Set:
When the current UV is under or over the threshold set by
Param21.
5
Page 7
Basic Command Mapped Command
Basic Set Basic Get Basic Report
6 Wakeup
The device stays in sleep status for the majority of time in order to conserve battery life. The minimum wakeup interval is 1800 seconds(30 minutes) The maximum wakeup interval is 86400 seconds(24 hours) The default wakeup interval is 28800 seconds(8 hours) The value is greater, the battery life is longer. Allowable min step among each wakeup interval is 60 seconds, such as 1860s, 1920s, 1980s...
Rev. 0.6
If the product is in sleep state for a long time and your gateway shows it is in offline state, you can rediscover it via pressing and holding the Action Button for 3 seconds, then the Sensor will send a wake_up notification report to your gateway and let your gateway that it is still online.
7 Battery
Battery level will be checked every time the device wake up. These includes the wakeup timer, motion trigger, button click. When the battery state changed, a battery report command will be sent to the controller.
8 Multilevel Sensor
The device has a temperature/humidity sensor and a ambient light/uv sensor. The ambient temperature/humidity and light/uv will be checked period.
See Param16,17,40,41,45,46,48,49,50,51 and 64 for more information.
Command Class Command Type Scale
See Param14,15,40,42,45,48,52,53,54 for more information.
Command Class Command
COMMAND_CLASS_SENSOR_MULTILEVEL SENSOR_MULTILEVEL_REPORT Air Temperature Celsius(EU) / Fahrenheit (US)
COMMAND_CLASS_SENSOR_MULTILEVEL SENSOR_MULTILEVEL_REPORT
6
Page 8
Rev. 0.6
Type Scale
Humidity Percentage value
See Param18,19,40,43,45,48,55,56,57 for more information.
Command Class Command Type Scale
COMMAND_CLASS_SENSOR_MULTILEVEL SENSOR_MULTILEVEL_REPORT Illuminance Lux
See Param20,21,40,44,45,48,58,59,60 for more information.
Command Class Command Type Scale
COMMAND_CLASS_SENSOR_MULTILEVEL SENSOR_MULTILEVEL_REPORT Ultraviolet UV index
9 Notification
Notification Type Notification Event/State Description
State idle
Home Security (0x07)
Power Management (0x08)
System(0x09) System software failure
Motion detection (0x08) When motion triggered. Tampering, product moved (0x09) When vibrating.
AC mains disconnected (0x02)
AC mains re-connected(0x03) When insert the USB cable. Replace battery soon (0x0A) When battery level below the param39 value. Replace battery now (0x0B) When battery level below 2.0V.
(manufacturer proprietary failure code provided) (0x04)
Notification value for the state variable going to idle.
When USB disconnected and insert battery again.
When watch dog timeout.
10 Manufacturer Information
Parameter Value
Manufacturer ID 1 0x03
Manufacturer ID 2 0x71
Product Type ID 1 0x00=EU, 0x01=US, 0x02=AU
Product Type ID 2 0x02
Product ID 1 0x00
7
Page 9
Product ID 2 0x18
11 Configuration
User can change the default settings by the below configuration parameters. After device reset, all these parameters will be set to their default values. Properties: R=Readable, W=Writable, S=Signed Integer, U=Unsigned Integer, E=Enumerated, B=Bit filed
(Param 1) Beaming Enable/Disable
Used to enable/disable beaming. If set to 1, FLiR commands will be supported and device type will be LSS. But the device must be re-included into the network to activate it.
Rev. 0.6
Parameter Number Size (Byte) Available Settings Default value Property
0x01 1 0/1 0 R/W/E
0 - disable 1 - enable
(Param 2) Motion Retrigger Time
Presence re-detection time set in second to allow motion sensor to reset timeout of motion sensor. In this time, the motion sensor can not be triggered again. If this value reach zero, the timeout configuration value set by Param3 will be reset.
Parameter Number Size (Byte) Available Settings Default value Property
0x02 2 0~3600 30 R/W/U
0 disable 1~30 - 30 seconds 30 ~ 3600 - timeout set in seconds
(Param 3) Motion Untrigger Time
Timeout configuration set in second for motion sensor to send no trigger status.
Parameter Number Size (Byte) Available Settings Default value Property
0x03 2 30~3600 240 R/W/U
(Param 4) Motion Sensitivity
Set the sensitivity of motion sensor.
Parameter Number Size (Byte) Available Settings Default value Property
0x04 1 0~11 11 R/W/U
0 - disable 1 - minimum sensitivity
8
Page 10
11 - maximum sensitivity
(Param 5) Motion Report Type
Set which command class will be sent when motion sensor is triggered or detriggered.
Parameter Number Size (Byte) Available Settings Default value Property
0x05 1 0/1/2 2 R/W/E
0 - Sends Notification Report 1 - Sends Sensor Binary Report 2 - Sends Notification and Sensor Binary Report
(Param 6) Vibration Sensor Enable/Disable
Used to enable/disable vibration sensor.
Rev. 0.6
Parameter Number Size (Byte) Available Settings Default value Property
0x06 1 0~255 255 R/W/U
0 - disable vibration 1~254 - timeout set in minutes to reset vibration status 255 - only send vibration triggered, does not timeout
(Param 7) Vibration Intensity Reports
Used to enable/disable vibration intensity reports. If set to 1, vibration intensity will be sent to gateway when triggered. If set to 0, do not report.
Parameter Number Size (Byte) Available Settings Default value Property
0x07 1 0/1 0 R/W/E
(Param 9) Wakeup CC Timeout
Timeout set in seconds after Wakeup CC is send out before go to sleep. If role type is RSS, the minimum value will be 10. If role type is LSS, the minimum value will be 2. If wakeup no more information received, return to sleep mode immediately.
Parameter Number Size (Byte) Available Settings Default value Property
0x09 1 2~255 15 R/W/U
(Param 10) Power Status
This value is Readonly. Used to report the power status (USB or Battery powered)
Parameter Number Size (Byte) Available Settings Default value Property
0x0A 1 0/1 - R/E
0 - When battery powered, the device will act as RSS. 1 - When USB cable insert, the device will act as AOS. The device must be re-included in the network to change the role type.
9
Page 11
(Param 11) Motion Group Control (Group2)
Set control of other devices on group2 based on motion trigger
Parameter Number Size (Byte) Available Settings Default value Property
0x0B 1 0/1/2/3/4/5/6 0 R/W/E
0 - Send BASIC_SET (0xFF) when motion is triggered to associated device
Send BASIC_SET (0x00) when motion is untriggered to associated device
1 - Send BASIC_SET (0x00) when motion is triggered
Send BASIC_SET (0xFF) when motion is untriggered 2 - Send BASIC_SET (0xFF) when motion is triggered, Nothing when motion untriggered. 3 - Send BASIC_SET (0x00) when motion is triggered, Nothing when motion untriggered. 4 - Send BASIC_SET (0x00) when motion is untriggered, Nothing when motion triggered. 5 - Send BASIC_SET (0xFF) when motion is untriggered, Nothing when motion triggered. 6 - Send BASIC_SET (value is configured by parameter 12) when motion is triggered to associated devices.
Send BASIC_SET (value is configured by parameter 12) when motion is untriggered.
Rev. 0.6
(Param 12) Motion Group Value Setting
Set Basic Set value for Group2. The MSB will act as the basic set value when motion trigger. The LSB will act as the basic set value when motion untrigger. E.g. value=0x0A00, then BASIC_SET(0x0A) will be sent when motion trigger, BASIC_SET(0x00) will be sent when motion untrigger.
Parameter Number Size (Byte) Available Settings Default value Property
0x0C 2 0~65535 65280 R/W/U
(Param 13) Motion Group Control Requirement
Set threshold of Light/Lux when devices associated in group2 should be triggered by motion. Associated device only receive BASIC_SET command when light <= (this value).
Parameter Number Size (Byte) Available Settings Default value Property
0x0D 2 0~30000 30000 R/W/U
(Param 14) Over Humidity Group Threshold (Group5)
Set threshold of humidity. If measured humidity >= (this value), send BASIC_SET (0xFF) to associated devices through group5. If measured humidity < (this value) send BASIC_SET (0x00) to associated devices through group5.
Parameter Number Size (Byte) Available Settings Default value Property
0x0E 1 0~100 60 R/W/U
(Param 15) Under Humidity Group Threshold (Group6)
Set threshold of humidity. If measure humidity <= (this value) send BASIC_SET (0xFF) to associated devices through group6. If measured humidity > (this value) send BASIC_SET (0x00) to associated devices through group6.
Parameter Number Size (Byte) Available Settings Default value Property
10
Page 12
0x0F 1 0 ~100 40 R/W/U
(Param 16) Over Heat Group Threshold (Group3)
Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature >= (this value, Scale is determined by Param64) send BASIC_SET (0xFF) to associated devices. If measured temperature < (this value) send BASIC_SET (0x00) to associated devices. E.g. Value 239 means 23.9 C. Value 750 means 75.0 F.
Parameter Number Size (Byte) Available Settings Default value Property
0x10 2 -400~850 (EU/AU)
-400~1850 (US)
239 (EU/AU) 750 (US)
R/W/S
(Param 17) Under Heat Group Threshold (Group4)
Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature <= (this value, Scale is determined by Param64) send BASIC_SET (0xFF) to associated devices. If measured temperature > (this value) send BASIC_SET (0x00) to associated devices. E.g. Value 155 means 15.5 C. Value 600 means 60.0 F.
Rev. 0.6
Parameter Number Size (Byte) Available Settings Default value Property
0x11 2 -400~850 (EU/AU)
-400~1850 (US)
155 (EU/AU) 600 (US)
R/W/S
(Param 18) Over Light Group Threshold (Group7)
Set threshold of Light/Lux. If measured light/lux >= (this value) send BASIC_SET (0xFF) to associated devices. If measured light/lux < (this value) send BASIC_SET (0x00) to associated devices.
Parameter Number Size (Byte) Available Settings Default value Property
0x12 2 0~30000 2000 R/W/U
(Param 19) Under Light Group Threshold (Group8)
Set threshold of Light/Lux. If measured light/lux <= (this value) send BASIC_SET (0xFF) to associated devices. If measured light/lux > (this value) send BASIC_SET (0x00) to associated devices.
Parameter Number Size (Byte) Available Settings Default value Property
0x13 2 0~30000 100 R/W/U
(Param 20) Over UV Group Threshold (Group9)
Set threshold of UV. If measured UV >= (this value) send BASIC_SET (0xFF) to associated devices. If measured UV < (this value) send BASIC_SET (0x00) to associated devices.
Parameter Number Size (Byte) Available Settings Default value Property
0x14 1 0~11 8 R/W/U
11
Page 13
(Param 21) Under UV Group Threshold (Group10)
Set threshold of UV. If measured UV <= (this value) send BASIC_SET (0xFF) to associated devices. If measured UV > (this value) send BASIC_SET (0x00 to associated devices.)
Parameter Number Size (Byte) Available Settings Default value Property
0x15 1 0~11 1 R/W/U
(Param 39) Low Battery Threshold
Configure low battery report threshold, sends low battery report via notification and battery report when battery level drops under setting. Unit %.
Parameter Number Size (Byte) Available Settings Default value Property
0x27 1 10~90 50 R/W/U
Rev. 0.6
(Param 40) Threshold Check Enable/Disable
Enable/Disable threshold reporting, check time can be adjusted by Param45.
Parameter Number Size (Byte) Available Settings Default value Property
0x28 1 0/1 0 R/W/E
0 - disable all threshold reports 1 - enable all threshold reports
(Param 41) Temperature Threshold
Threshold = (Value * 0.1) Scale is determined by Param64. 0 = disable.
Parameter Number Size (Byte) Available Settings Default value Property
0x29 1 0~255 10 R/W/U
(Param 42) Humidity Threshold
Humidity range = 1% to 50%, 0 = disable.
Parameter Number Size (Byte) Available Settings Default value Property
0x2A 1 0~50 5 R/W/U
(Param 43) Lux Threshold
0 = disable.
Parameter Number Size (Byte) Available Settings Default value Property
0x2B 2 0~10000 250 R/W/U
(Param 44) UV Threshold
0 = disable.
12
Page 14
Parameter Number Size (Byte) Available Settings Default value Property
0x2C 1 0~11 1 R/W/U
(Param 45) Threshold Check Time
Set threshold check time in seconds if threshold is enable via Param40.
Parameter Number Size (Byte) Available Settings Default value Property
0x2D 2 1~65535 240 R/W/U
1~65535 - When USB powered 60~65535 - When Battery powered
(Param 46) Low Temperature Report
Eable/Disable alarm report for low temperature(<= -15 C) Multilevel CC temperature report will be sent to gateway.
Rev. 0.6
Parameter Number Size (Byte) Available Settings Default value Property
0x2E 1 0/1 1 R/W/E
0 - disable 1 - enable
(Param 48) Sensor Limit Control
This value is bit mask. Used to enable/disable measurement reports for various sensors that is more than the upper limit value or less than the lower limit value.
Parameter Number Size (Byte) Available Settings Default value Property
0x30 1 1|2|4|8|16|32|64|128 0 R/W/B
0 - Disabled 1 - Temperature upper level 2 - Humidity upper level 4 - Lux upper level 8 - UV upper level 16 - Temperature lower level 32 - Humidity lower level 64 - Lux lower level 128 - UV lower level
(Param 49) Temperature Upper Limit
Set upper limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current measurement) > (Upper Limit), then report sensor.
Parameter Number Size (Byte) Available Settings Default value Property
0x31 2 -400~1000 (EU/AU)
-400~2120 (US)
280 (EU/AU) 824 (US)
R/W/S
13
Page 15
(Param 50) Temperature Lower Limit
Set lower limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current Measurement) < (Lower limit), then report sensor.
Parameter Number Size (Byte) Available Settings Default value Property
0x32 2 -400~1000 (EU/AU)
-400~2120 (US)
0 (EU/AU) 320 (US)
R/W/S
(Param 51) Temperature Recover Limit
Temperature recover limit set in scale of 0.1. Scale is determined by Param64. If (Current measurement) <= (upper limit - recover limit), then temperature report. If (Current measurement) >= (lower limit + recover limit), then temperature report.
Parameter Number Size (Byte) Available Settings Default value Property
0x33 1 1~255 20 R/W/U
Rev. 0.6
(Param 52) Humidity Upper Limit
Set humidity upper limit level.
Parameter Number Size (Byte) Available Settings Default value Property
0x34 1 0~100 60 R/W/U
(Param 53) Humidity Lower Limit
Set humidity lower limit level.
Parameter Number Size (Byte) Available Settings Default value Property
0x35 1 0~100 40 R/W/U
(Param 54) Humidity Recover Limit
Set humidity recover limit level. Refer to Param 51.
Parameter Number Size (Byte) Available Settings Default value Property
0x36 1 1~50 5 R/W/U
(Param 55) Lux Upper Limit
Set lux upper limit level.
Parameter Number Size (Byte) Available Settings Default value Property
0x37 2 0~30000 1000 R/W/U
14
Page 16
(Param 56) Lux Lower Limit
Set lux lower limit level.
Parameter Number Size (Byte) Available Settings Default value Property
0x38 2 0~30000 100 R/W/U
(Param 57) Lux Recover Limit
Set lux recover limit level. Refer to Param 51.
Parameter Number Size (Byte) Available Settings Default value Property
0x39 1 1~255 100 R/W/U
(Param 58) UV Upper Limit
Rev. 0.6
Set UV upper limit level.
Parameter Number Size (Byte) Available Settings Default value Property
0x3A 1 1~11 8 R/W/U
(Param 59) UV Lower Limit
Set UV lower limit level.
Parameter Number Size (Byte) Available Settings Default value Property
0x3B 1 1~11 4 R/W/U
(Param 60) UV Recover Limit
Set UV recover limit level. Refer to Param 51.
Parameter Number Size (Byte) Available Settings Default value Property
0x3C 1 1~5 1 R/W/U
(Param 61) Out-of-limit State
This is read only and bit mask. Out of the limit state of sensors.
Parameter Number Size (Byte) Available Settings Default value Property
0x3D 1 - - R/B
Bit Mask:
0 - within limit 1 - out of limit
Value:
15
Page 17
1 - Temperature upper level 2 - Humidity upper level 4 - Lux upper level 8 - UV upper level 16 - Temperature lower level 32 - Humidity lower level 64 - Lux lower level 128 - UV lower level
(Param 64) Temperature Scale
Set the scale for temperature when reports.
Parameter Number Size (Byte) Available Settings Default value Property
0x40 1 0/1 0 (EU/AU)
1 (US)
0 - Celsius 1 - Fahrenheit
R/W/E
Rev. 0.6
(Param 81) LED Activity
Allow user to enable/disable LED activity of specific reports sent by sensor. Button press indicator is not affected by this.
Parameter Number Size (Byte) Available Settings Default value Property
0x51 1 0/1 1 R/W/E
0 - disable 1 - enable
(Param 82) Motion Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of motion sensor.
Parameter Number Size (Byte) Available Settings Default value Property
0x52 1 0/1/2/3/4/5/6/7/8/9 3 R/W/E
0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White
16
Page 18
(Param 83) Temperature Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of temperature sensor.
Parameter Number Size (Byte) Available Settings Default value Property
0x53 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White
Rev. 0.6
(Param 84) Humidity Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of humidity sensor.
Parameter Number Size (Byte) Available Settings Default value Property
0x54 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White
(Param 85) Lux Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of Lux sensor.
Parameter Number Size (Byte) Available Settings Default value Property
0x55 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan
17
Page 19
6 - Purple 7 - Orange 8 - Yellow 9 - White
(Param 86) UV Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of UV sensor.
Parameter Number Size (Byte) Available Settings Default value Property
0x56 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White
Rev. 0.6
(Param 87) Vibration Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of vibration sensor.
Parameter Number Size (Byte) Available Settings Default value Property
0x57 1 0/1/2/3/4/5/6/7/8/9 2 R/W/E
0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White
(Param 88) Battery Report Indicator
If LED is enabled by Param81, allow user to change the report color of battery.
Parameter Number Size (Byte) Available Settings Default value Property
0x58 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0 - Disabled
18
Page 20
1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White
(Param 89) Wakeup Report Indicator
If LED is enabled by Param81, allow user to change the report color of wakeup.
Parameter Number Size (Byte) Available Settings Default value Property
0x59 1 0/1/2/3/4/5/6/7/8/9 8 R/W/E
0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White
Rev. 0.6
(Param 90) Communication Indicator
If LED is enabled by Param81, allow user to change indicator color when receiving communication from gateway or other devices.
Parameter Number Size (Byte) Available Settings Default value Property
0x5A 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0 - Disabled 1 - Red 2 - Blue 3 - Green 4 - Pink 5 - Cyan 6 - Purple 7 - Orange 8 - Yellow 9 - White
19
Page 21
(Param 101) Automatic Report Checklist 1
Checklist 1 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param111.
Parameter Number Size (Byte) Available Settings Default value Property
0x65 1 1|16|32|64|128 241 R/W/B
0 - Disabled 1 - Battery 16 - UV 32 - Temperature 64 - Humidity 128 - Lux Default 241 = 1 + 16 + 32 + 64 + 128, means all enable.
Rev. 0.6
(Param 102) Automatic Report Checklist 2
Checklist 2 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param112.
Parameter Number Size (Byte) Available Settings Default value Property
0x66 1 1|16|32|64|128 0 R/W/B
0 - Disabled 1 - Battery 16 - UV 32 - Temperature 64 - Humidity 128 - Lux Max value 241 = 1 + 16 + 32 + 64 + 128, means all enable.
(Param 103) Automatic Report Checklist 3
Checklist 3 for automatic timed report. When the corresponding item is selected, it will be checked when timeout setting by Param113.
Parameter Number Size (Byte) Available Settings Default value Property
0x67 1 1|16|32|64|128 0 R/W/B
0 - Disabled 1 - Battery 16 - UV 32 - Temperature 64 - Humidity 128 - Lux Max value 241 = 1 + 16 + 32 + 64 + 128, means all enable.
20
Page 22
(Param 111) Automatic Checklist 1 Interval Time
Interval time set in seconds to check the checklist1’s items. Multilevel Sensor Report will be sent when timeout.
Parameter Number Size (Byte) Available Settings Default value Property
0x6F 2 30~65535 3600 R/W/U
(Param 112) Automatic Checklist 2 Interval Time
Interval time set in seconds to check the checklist2’s items. Multilevel Sensor Report will be sent when timeout.
Parameter Number Size (Byte) Available Settings Default value Property
0x70 2 30~65535 3600 R/W/U
(Param 113) Automatic Checklist 3 Interval Time
Rev. 0.6
Interval time set in seconds to check the checklist3’s items. Multilevel Sensor Report will be sent when timeout.
Parameter Number Size (Byte) Available Settings Default value Property
0x71 2 30~65535 3600 R/W/U
(Param 201) Temperature Offset Value
Can add or minus this setting value to calibrate temperature when checked. Scale is defined by Param64. e.g. Value 15 means 1.5C or 1.5F.
Parameter Number Size (Byte) Available Settings Default value Property
0xC9 2 -200 ~200 0 R/W/S
(Param 202) Humidity Offset Value
Can add or minus this setting value to calibrate humidity when checked. Unit: %.
Parameter Number Size (Byte) Available Settings Default value Property
0xCA 1 -100~100 0 R/W/S
(Param 203) Lux Offset Value
Can add or minus this setting value to calibrate Lux when checked.
Parameter Number Size (Byte) Available Settings Default value Property
0xCB 2 -10000~10000 0 R/W/S
(Param 204) UV Offset Value
Can add or minus this setting value to calibrate UV when checked.
Parameter Number Size (Byte) Available Settings Default value Property
0xCC 1 -10~10 0 R/W/S
Multilevel Sensor Report will be sent when timeout.
21
Page 23
Rev. 0.6
12 Security Network
This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products.
The device supports the security function with S0 and S2 encrypted communication. The device will auto switch to the security mode when the device included with a security controller. In the security mode, the commands will use security and security2 command class wrapped to communicate with others, otherwise the device will not response any commands.
This device supports security levels are listed in below table:
Security Levels
SECURITY_KEY_S0 Yes
SECURITY_KEY_S2_UNAUTHENTICATED Yes
SECURITY_KEY_S2_AUTHENTICATED Yes
SECURITY_KEY_S2_ACCESS No
Support (Yes/No)
13 SmartStart
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. You can find the QR code on the bottom of the product, like this:
The DSK information will be like this: 03904-29465-27012-32844-35506-05493-46416-50723
14 Specifications
Power Supply CR123A × 2 or USB powered
Sleep Current 27uA
Wakeup Current 16mA
Action Current 30mA
22
Page 24
0m for
Inclusion/Exclusion Current 35mA
Power LED RGB LED
Temperature Sensor -10°C to 50°C / 14°F to 122°F with accuracy of ±0.5°C
Humidity Sensor 20%RH—80%RH,accuracy:±5% RH(at 25℃)
Rev. 0.6
Light Sensor
Communication Frequency
Communication Range
Communication Certification Z-Wave Plus with Smart Start
Operational Temperature 0 - 40/ 32 - 104℉
Operating Humidity 8% to 80%
0 LUX to 30000 LUX with ±3% accuracy UV 0~11
868.40MHz, 869.85MHz (EU)
908.40MHz, 916.00MHz (US) Up to 70m+ indoors (depending on the building structure) and 15 outdoors/ open fields.
23