Association Group Information 3 Support Support Support
Multi Channel Association3 Support Support Support
Battery1 Support Support Support
Binary Sensor2 Support Support Support
Multilevel Sensor11 Support Support Support
Notification8 Support Support Support
Not
added
Non-secureadded
Securelyadded
Non-secureCCSecureCC
Application Status1 Support Support Support
Configuration 4 Support Support Support
Transport Service2 Support Support Support
1
Page 3
Version 3 Support Support Support
Wakeup 2 Support Support Support
Manufacturer Specific2 Support Support Support
Device Reset Locally1 Support Support Support
Indicator 3 Support Support Support
Powerlevel1 Support Support Support
Security 0/21 Support Support Support
Supervision 1 Support Support Support
Firmware Update Meta Data5 Support Support Support
2 Z-Wave™ Network Operation
Rev. 0.6
FunctionsAction
Button
1
Add
Remove
Wakeup Notify Hold for 2~5s
1
Tap one time
Tap one time
Description
Add this device intoan existing Z-Wave network:
1.Power on the device, the power led will blink blue slowly.
2.Let the Primary Controller into inclusion mode (If you don’t knowhow to do this, refer to its manual)
3.Press the action button one time, when the yellow led on release thebutton. It indicates the device has enter learn mode.
4.If added successful, the power led will flash (white -> green -> white -> green at a rate of 250ms per each color) for 2 seconds.
Remove this device from an existing Z-Wave network:
1.Power on the device.
1.Let the Primary Controller into exclusion mode (If you don’t knowhow to do this refer to its manual)
2.Press the action button onetime, when the purple led on release thebutton. It indicates the device has enter learn mode.If removed successful, the blue led will blink slowly.
1.Power on and make sure the device has been included into Z-Wave network.
2.Pressand hold the buttonat least 2s until Red Led Is On and thenrelease the button, device will send wake up notification to controller ifdevice is in a Z-Wave network.
2
Page 4
Enter 5 minutes wakeup state:
1.Power on and make sure the device has been included into Z-Wave network.
2.Pressand hold button for 5seconds, when orange led on release it. If5 Minutes WakupState
orange led keep on, it indicates state entered.Exit 5 minutes wakeup state:
1.Power on and make sure the device has been included into Z-Wave
network.
2.Pressand hold button for 5seconds, when orange led on release it. If
led off, it indicates state exited.
1.Power on the device and make sure it hasbeen included into the Z-
Wave network.
2.Press and hold the buttonfor 9 seconds, when the cyan led on release
the button. Then, it will enter the power level test mode. At this mode,the Hot Water Switch device will send 100frames to remote device todiagnostic network quality.
3.After the test, if >= 97 frames receive ACK, the green led will turn on2
seconds. This indicates the network is Good.
4.If >=90frames receive ACK,the yellow led will turn on 2 seconds. This
indicates the network is OK.
5.If < 90frames receiveACK, the red led will turn on 2seconds. This
indicates the network is Bad.
1.Make sure the device has been powered.
2.Pressand hold the button for 15 seconds. When the red led flash, the
device will enter factory reset mode.
3.If reset successful, the blue led will blink slowly.
Rev. 0.6
3 Button Action and LED Indicator
Unit: second
ActionPressdownAction
Button
Tap 1 time [0.04, 1)Solid yellow status
ReleaseActionButton
Turns on a solid yellow status, If a new node id is assigned to thisdevice, the yellow LED will keepsolid until whole network processing is complete (or entering.If successful, the LED will flash white -> green -> white -> green (at a rate of 250ms per each color change) for 2seconds. After 2 secondshave finished, use typical paired status LED indicators forON/OFF status from parameter #1.
3
Page 5
Rev. 0.6
Tap 2 times [0.04, 1)
Tap 4 times [0.04, 2)N/A
Press and hold [1, 2) Turn LED off
Press and hold [2, 5) Solid orange status
Press and hold [5, 9) Solid cyan status See power level test mode.
Press and hold [9, 15) Solid red statusN/A
Press and hold [15, 20)
Press and hold [20, ∞) N/A N/A
Purple LED keeps on for 2 seconds and then off
Red color will blinkon and off at a rate of 200ms for 2seconds and then pulseblue color if removed
If exclusion is successful, the LED should pulse bluecolor slowly.
If parameter 32 isset to 2,this will be used to cancel thealarm. See parameter 30,31,32 for more information.
LED revert back to LED statebased on network state.If parameter 32 isset to 4,this will be used to cancel the
alarm. See parameter 30,31,32 for more information.
Reset to factory default
4 Association Groups
The device supports 11association groups andeverygroupsupports max 5associated nodes.Group 1 is lifeline group, allnodes which associated in this group will receive the messages sent by device through lifeline.
The Command Class supported by each association group is shown in the tablebelow:
Root Device
IDNameN
ProfileDescriptionodes
Device Reset Locally:
1 Lifeline5General: Lifeline
When factory reset.
Notification Report:
See Notification Chapter for more information.
4
Page 6
2 Motion 5General: NA
by
by
Sensor Binary Report:
See Param5for more information.
Sensor Multilevel Report:
When sensors above over limit or below under limit.
Battery Report:
See Param101.
Indicator Report:
Issued when the indicator light changed.
Basic Set:
Basic Set Command willbe sent to the associated device whenmotion trigger or untrigger. The basic set value is determined
by Param11, Param12. See Param13for more information.
Rev. 0.6
3 OverHeat 5Sensor:Temperature
4 UnderHeat5Sensor:Temperature
5 OverHumidity5Sensor:Humidity
6 UnderHumidity5Sensor:Humidity
7 OverLight5Sensor:Illuminance
8 UnderLight5Sensor:Illuminance
Basic Set:
When the temperature change value is over or under the threshold set by Param16. Scale is determined by Param64.
Basic Set:
When the temperature change value is under or over the threshold set by Param17. Scale is determined by Param64.
Basic Set:
When the current humidity is over or under the threshold set by Param14.
Basic Set:
When the current humidity is under or over the threshold set by Param15.
Basic Set:
When the current light/lux is over or under the threshold set
Param18.
Basic Set:
When the current light/lux is under or over the threshold set
Param19.
9 OverUV5Sensor:Ultraviolet
10UnderUV5Sensor:Ultraviolet
11Temperature5Sensor:Temperature
5 Basic Command Map
Basic Set:
When the current UV is overor under the threshold set by
Param20.
Basic Set:
When the current UV is under or over the threshold set by
Param21.
5
Page 7
BasicCommandMappedCommand
Basic Set Basic GetBasic Report
6 Wakeup
The device stays in sleep status for the majority of time in order to conserve battery life. The minimum wakeup interval is 1800 seconds(30 minutes)The maximumwakeup interval is 86400 seconds(24 hours)The default wakeup interval is 28800 seconds(8 hours) The value is greater, the battery life is longer.Allowable min step among each wakeup interval is 60 seconds, such as 1860s, 1920s, 1980s...
Rev. 0.6
If the product is in sleep state for a long time and your gateway shows it is in offline state, you can rediscover it
via pressing and holding the Action Button for 3 seconds, then the Sensor will send a wake_up notification
report to your gateway and let your gateway that it is still online.
7 Battery
Battery level will be checked every time the device wake up. These includes the wakeup timer, motion trigger, button click.When the battery state changed, a battery report command will be sent to the controller.
8 Multilevel Sensor
The device has a temperature/humidity sensor and a ambient light/uv sensor. The ambient temperature/humidity andlight/uv will be checked period.
See Param16,17,40,41,45,46,48,49,50,51 and 64 for more information.
Command ClassCommandType Scale
See Param14,15,40,42,45,48,52,53,54 for more information.
Command ClassCommand
COMMAND_CLASS_SENSOR_MULTILEVELSENSOR_MULTILEVEL_REPORT Air TemperatureCelsius(EU) / Fahrenheit (US)
Motion detection (0x08) When motion triggered.Tampering, product moved (0x09) When vibrating.
AC mains disconnected (0x02)
AC mains re-connected(0x03) When insert the USB cable. Replace battery soon (0x0A)When battery level below the param39 value. Replace battery now (0x0B) When battery level below 2.0V.
Notification value for the state variable going toidle.
When USBdisconnectedandinsert battery again.
When watch dog timeout.
10 Manufacturer Information
ParameterValue
Manufacturer ID 10x03
Manufacturer ID 20x71
Product Type ID 10x00=EU, 0x01=US, 0x02=AU
Product Type ID 20x02
Product ID 1 0x00
7
Page 9
Product ID 2 0x18
11 Configuration
User can change the defaultsettings by the below configuration parameters. After device reset, all these parameterswill be set to their default values. Properties: R=Readable, W=Writable, S=Signed Integer, U=Unsigned Integer, E=Enumerated, B=Bit filed
(Param 1) Beaming Enable/Disable
Used to enable/disable beaming. If set to 1, FLiR commands will be supported and device type will be LSS. But thedevice must be re-included into the network to activate it.
Rev. 0.6
Parameter NumberSize (Byte) Available Settings Default value Property
0x01 1 0/1 0 R/W/E
0- disable 1 - enable
(Param 2) Motion Retrigger Time
Presence re-detection time set in second toallow motion sensor to reset timeout of motion sensor. In this time, themotion sensor can not be triggered again. If this value reach zero, the timeout configuration value set by Param3will be reset.
Parameter NumberSize (Byte) Available Settings Default value Property
0x02 2 0~3600 30 R/W/U
0– disable1~30- 30seconds30~ 3600- timeout set in seconds
(Param 3) Motion Untrigger Time
Timeout configuration set insecond for motion sensor to send no trigger status.
Parameter NumberSize (Byte) Available Settings Default value Property
0x03 2 30~3600 240 R/W/U
(Param 4) Motion Sensitivity
Set the sensitivity of motionsensor.
Parameter NumberSize (Byte) Available Settings Default value Property
0x04 1 0~11 11 R/W/U
0- disable 1 - minimum sensitivity
8
Page 10
11 - maximum sensitivity
(Param 5) Motion Report Type
Set which command class will be sent when motion sensor is triggered or detriggered.
Parameter NumberSize (Byte) Available Settings Default value Property
Parameter NumberSize (Byte) Available Settings Default value Property
0x06 1 0~255 255 R/W/U
0- disable vibration1~254 - timeout set in minutes to reset vibration status255 - only send vibration triggered, does not timeout
(Param 7) Vibration Intensity Reports
Used to enable/disable vibration intensity reports. If set to 1, vibration intensity will be sent to gateway when triggered. If set to 0, do not report.
Parameter NumberSize (Byte) Available Settings Default value Property
0x07 1 0/1 0 R/W/E
(Param 9) Wakeup CC Timeout
Timeout set in seconds after Wakeup CC is send out before go to sleep. If role type is RSS, the minimum value will be 10. If role type is LSS, the minimum value will be 2. If wakeup no more information received, return tosleepmode immediately.
Parameter NumberSize (Byte) Available Settings Default value Property
0x09 1 2~255 15 R/W/U
(Param 10) Power Status
This value is Readonly. Used to report the power status (USB or Battery powered)
Parameter NumberSize (Byte) Available Settings Default value Property
0x0A 1 0/1 - R/E
0- When battery powered, the device will act as RSS.1 - When USB cable insert, the device will act as AOS. The device must be re-included in the network to change the role type.
9
Page 11
(Param 11) Motion Group Control (Group2)
Set control of other devices on group2 based on motiontrigger
Parameter NumberSize (Byte) Available Settings Default value Property
0x0B 1 0/1/2/3/4/5/6 0 R/W/E
0- Send BASIC_SET (0xFF) when motion is triggered to associated device
Send BASIC_SET (0x00) when motion is untriggered to associated device
1 - Send BASIC_SET (0x00) when motion is triggered
Send BASIC_SET (0xFF) when motion is untriggered2 - Send BASIC_SET (0xFF) when motion is triggered, Nothing when motion untriggered.3 - Send BASIC_SET (0x00) when motion is triggered, Nothing when motion untriggered.4 - Send BASIC_SET (0x00) when motion is untriggered, Nothing when motion triggered.5 - Send BASIC_SET (0xFF) when motion is untriggered, Nothing when motion triggered.6 - Send BASIC_SET (value is configured by parameter 12) when motion is triggeredto associated devices.
Send BASIC_SET (value is configured by parameter 12) when motion is untriggered.
Rev. 0.6
(Param 12) Motion Group Value Setting
Set Basic Set value for Group2. The MSB will act as the basic set value when motion trigger. The LSB will act as thebasic set value when motion untrigger. E.g. value=0x0A00, then BASIC_SET(0x0A)will be sent whenmotion trigger,BASIC_SET(0x00) will be sent when motion untrigger.
Parameter NumberSize (Byte) Available Settings Default value Property
0x0C 2 0~65535 65280 R/W/U
(Param 13) Motion Group Control Requirement
Set thresholdof Light/Lux when devices associated in group2 should be triggered by motion. Associated deviceonlyreceive BASIC_SET command when light <= (this value).
Parameter NumberSize (Byte) Available Settings Default value Property
0x0D 2 0~30000 30000 R/W/U
(Param 14) Over Humidity Group Threshold (Group5)
Set threshold of humidity. If measured humidity >= (this value), send BASIC_SET (0xFF) to associated devicesthrough group5. If measured humidity < (this value) send BASIC_SET (0x00) to associated devices through group5.
Parameter NumberSize (Byte) Available Settings Default value Property
0x0E 1 0~100 60 R/W/U
(Param 15) Under Humidity Group Threshold (Group6)
Set threshold of humidity. Ifmeasure humidity <= (this value) send BASIC_SET (0xFF) to associated devices throughgroup6. If measured humidity > (this value) send BASIC_SET (0x00) to associated devices through group6.
Parameter NumberSize (Byte) Available Settings Default value Property
10
Page 12
0x0F 1 0 ~100 40 R/W/U
(Param 16) Over Heat Group Threshold (Group3)
Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature >= (this value, Scale is determined by Param64) send BASIC_SET (0xFF) to associated devices.If measured temperature <(this value) send BASIC_SET (0x00) to associated devices.E.g. Value 239 means 23.9 C.Value 750means 75.0F.
Parameter NumberSize (Byte) Available Settings Default value Property
0x10 2 -400~850 (EU/AU)
-400~1850 (US)
239 (EU/AU)
750 (US)
R/W/S
(Param 17) Under Heat Group Threshold (Group4)
Set threshold of temperature. Designed to control Air Conditioners or temperature controllers ON or OFF. If measured temperature <= (this value, Scale is determined by Param64) send BASIC_SET (0xFF) to associated devices.If measured temperature >(this value) send BASIC_SET (0x00) to associated devices. E.g. Value 155 means 15.5 C.Value 600means 60.0F.
Rev. 0.6
Parameter NumberSize (Byte) Available Settings Default value Property
0x11 2 -400~850 (EU/AU)
-400~1850 (US)
155 (EU/AU)
600 (US)
R/W/S
(Param 18) Over Light Group Threshold (Group7)
Set threshold of Light/Lux.If measured light/lux >= (this value) send BASIC_SET(0xFF) to associated devices. Ifmeasured light/lux < (this value) send BASIC_SET (0x00)to associated devices.
Parameter NumberSize (Byte) Available Settings Default value Property
0x12 2 0~30000 2000 R/W/U
(Param 19) Under Light Group Threshold (Group8)
Set threshold of Light/Lux.If measured light/lux <= (this value) send BASIC_SET(0xFF) to associated devices. Ifmeasured light/lux > (this value) send BASIC_SET (0x00)to associated devices.
Parameter NumberSize (Byte) Available Settings Default value Property
0x13 2 0~30000 100 R/W/U
(Param 20) Over UV Group Threshold (Group9)
Set threshold of UV. If measured UV >= (this value) send BASIC_SET (0xFF) to associated devices. If measured UV <(this value) send BASIC_SET (0x00) to associated devices.
Parameter NumberSize (Byte) Available Settings Default value Property
0x14 1 0~11 8 R/W/U
11
Page 13
(Param 21) Under UV Group Threshold (Group10)
Set threshold of UV. If measured UV <= (this value) send BASIC_SET (0xFF) to associated devices. If measured UV >(this value) send BASIC_SET (0x00to associated devices.)
Parameter NumberSize (Byte) Available Settings Default value Property
0x15 1 0~11 1 R/W/U
(Param 39) Low Battery Threshold
Configure low battery report threshold, sends low battery report via notification and battery report when batterylevel drops under setting. Unit %.
Parameter NumberSize (Byte) Available Settings Default value Property
0x27 1 10~90 50 R/W/U
Rev. 0.6
(Param 40) Threshold Check Enable/Disable
Enable/Disable threshold reporting, check time can be adjusted by Param45.
Parameter NumberSize (Byte) Available Settings Default value Property
0x28 1 0/1 0 R/W/E
0- disable all threshold reports1 - enable all threshold reports
(Param 41) Temperature Threshold
Threshold = (Value * 0.1) Scale is determined by Param64. 0= disable.
Parameter NumberSize (Byte) Available Settings Default value Property
0x29 1 0~255 10 R/W/U
(Param 42) Humidity Threshold
Humidity range = 1% to 50%, 0= disable.
Parameter NumberSize (Byte) Available Settings Default value Property
0x2A 1 0~50 5 R/W/U
(Param 43) Lux Threshold
0= disable.
Parameter NumberSize (Byte) Available Settings Default value Property
0x2B 2 0~10000 250 R/W/U
(Param 44) UV Threshold
0= disable.
12
Page 14
Parameter NumberSize (Byte) Available Settings Default value Property
0x2C 1 0~11 1 R/W/U
(Param 45) Threshold Check Time
Set threshold check time in seconds if threshold is enable via Param40.
Parameter NumberSize (Byte) Available Settings Default value Property
0x2D 2 1~65535 240 R/W/U
1~65535 - When USB powered60~65535 - When Battery powered
(Param 46) Low Temperature Report
Eable/Disable alarm report for low temperature(<= -15 C) Multilevel CC temperature report will be sent to gateway.
Rev. 0.6
Parameter NumberSize (Byte) Available Settings Default value Property
0x2E 1 0/1 1 R/W/E
0- disable 1 - enable
(Param 48) Sensor Limit Control
This value is bit mask. Usedto enable/disablemeasurement reports for various sensors that is more than the upperlimit value or less than the lower limit value.
Parameter NumberSize (Byte) Available Settings Default value Property
Set upper limit level for temperature set in scale of 0.1. Scale is determined by Param64. If (Current measurement) >(Upper Limit), then report sensor.
Parameter NumberSize (Byte) Available Settings Default value Property
0x31 2 -400~1000 (EU/AU)
-400~2120 (US)
280 (EU/AU)
824 (US)
R/W/S
13
Page 15
(Param 50) Temperature Lower Limit
Set lowerlimit level for temperature set in scale of0.1. Scale is determined by Param64. If (Current Measurement) <(Lower limit), then report sensor.
Parameter NumberSize (Byte) Available Settings Default value Property
0x32 2 -400~1000 (EU/AU)
-400~2120 (US)
0 (EU/AU)
320 (US)
R/W/S
(Param 51) Temperature Recover Limit
Temperature recover limit set in scale of 0.1. Scale is determined by Param64. If (Current measurement) <= (upperlimit - recover limit), thentemperature report. If (Current measurement) >= (lower limit + recover limit), thentemperature report.
Parameter NumberSize (Byte) Available Settings Default value Property
0x33 1 1~255 20 R/W/U
Rev. 0.6
(Param 52) Humidity Upper Limit
Set humidity upper limit level.
Parameter NumberSize (Byte) Available Settings Default value Property
0x34 1 0~100 60 R/W/U
(Param 53) Humidity Lower Limit
Set humidity lower limit level.
Parameter NumberSize (Byte) Available Settings Default value Property
0x35 1 0~100 40 R/W/U
(Param 54) Humidity Recover Limit
Set humidity recover limit level. Refer to Param 51.
Parameter NumberSize (Byte) Available Settings Default value Property
0x36 1 1~50 5 R/W/U
(Param 55) Lux Upper Limit
Set lux upper limit level.
Parameter NumberSize (Byte) Available Settings Default value Property
0x37 2 0~30000 1000 R/W/U
14
Page 16
(Param 56) Lux Lower Limit
Set lux lower limit level.
Parameter NumberSize (Byte) Available Settings Default value Property
0x38 2 0~30000 100 R/W/U
(Param 57) Lux Recover Limit
Set lux recover limit level. Refer to Param 51.
Parameter NumberSize (Byte) Available Settings Default value Property
0x39 1 1~255 100 R/W/U
(Param 58) UV Upper Limit
Rev. 0.6
Set UV upper limit level.
Parameter NumberSize (Byte) Available Settings Default value Property
0x3A 1 1~11 8 R/W/U
(Param 59) UV Lower Limit
Set UV lower limit level.
Parameter NumberSize (Byte) Available Settings Default value Property
0x3B 1 1~11 4 R/W/U
(Param 60) UV Recover Limit
Set UV recover limit level. Refer to Param 51.
Parameter NumberSize (Byte) Available Settings Default value Property
0x3C 1 1~5 1 R/W/U
(Param 61) Out-of-limit State
This is read only and bit mask. Out of the limit state of sensors.
Parameter NumberSize (Byte) Available Settings Default value Property
Parameter NumberSize (Byte) Available Settings Default value Property
0x40 1 0/1 0 (EU/AU)
1 (US)
0- Celsius 1 - Fahrenheit
R/W/E
Rev. 0.6
(Param 81) LED Activity
Allow user to enable/disable LED activity of specific reports sent by sensor. Button press indicator is not affected bythis.
Parameter NumberSize (Byte) Available Settings Default value Property
0x51 1 0/1 1 R/W/E
0- disable 1 - enable
(Param 82) Motion Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of motion sensor.
Parameter NumberSize (Byte) Available Settings Default value Property
0x52 1 0/1/2/3/4/5/6/7/8/9 3 R/W/E
0- Disabled 1 - Red 2 - Blue3 - Green 4 - Pink5 - Cyan6 - Purple 7 - Orange8 - Yellow 9 - White
16
Page 18
(Param 83) Temperature Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of temperature sensor.
Parameter NumberSize (Byte) Available Settings Default value Property
0x53 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0- Disabled 1 - Red 2 - Blue3 - Green 4 - Pink5 - Cyan6 - Purple 7 - Orange8 - Yellow 9 - White
Rev. 0.6
(Param 84) Humidity Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of humidity sensor.
Parameter NumberSize (Byte) Available Settings Default value Property
0x54 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0- Disabled 1 - Red 2 - Blue3 - Green 4 - Pink5 - Cyan6 - Purple 7 - Orange8 - Yellow 9 - White
(Param 85) Lux Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of Lux sensor.
Parameter NumberSize (Byte) Available Settings Default value Property
0x55 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0- Disabled 1 - Red 2 - Blue3 - Green 4 - Pink5 - Cyan
17
Page 19
6 - Purple 7 - Orange8 - Yellow 9 - White
(Param 86) UV Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of UV sensor.
Parameter NumberSize (Byte) Available Settings Default value Property
0x56 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0- Disabled 1 - Red 2 - Blue3 - Green 4 - Pink5 - Cyan6 - Purple 7 - Orange8 - Yellow 9 - White
Rev. 0.6
(Param 87) Vibration Sensor Report Indicator
If LED is enabled by Param81, allow user to change the report color of vibration sensor.
Parameter NumberSize (Byte) Available Settings Default value Property
0x57 1 0/1/2/3/4/5/6/7/8/9 2 R/W/E
0- Disabled 1 - Red 2 - Blue3 - Green 4 - Pink5 - Cyan6 - Purple 7 - Orange8 - Yellow 9 - White
(Param 88) Battery Report Indicator
If LED is enabled by Param81, allow user to change the report color of battery.
Parameter NumberSize (Byte) Available Settings Default value Property
0x58 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0- Disabled
18
Page 20
1 - Red 2 - Blue3 - Green 4 - Pink5 - Cyan6 - Purple 7 - Orange8 - Yellow 9 - White
(Param 89) Wakeup Report Indicator
If LED is enabled by Param81, allow user to change the report color of wakeup.
Parameter NumberSize (Byte) Available Settings Default value Property
0x59 1 0/1/2/3/4/5/6/7/8/9 8 R/W/E
0- Disabled 1 - Red 2 - Blue3 - Green 4 - Pink5 - Cyan6 - Purple 7 - Orange8 - Yellow 9 - White
Rev. 0.6
(Param 90) Communication Indicator
If LED is enabled by Param81, allow user to change indicator color when receiving communication from gateway orother devices.
Parameter NumberSize (Byte) Available Settings Default value Property
0x5A 1 0/1/2/3/4/5/6/7/8/9 0 R/W/E
0- Disabled 1 - Red 2 - Blue3 - Green 4 - Pink5 - Cyan6 - Purple 7 - Orange8 - Yellow 9 - White
19
Page 21
(Param 101) Automatic Report Checklist 1
Checklist 1 for automatic timed report. When the corresponding item is selected,it will be checked when timeoutsetting by Param111.
Parameter NumberSize (Byte) Available Settings Default value Property
0x65 1 1|16|32|64|128 241 R/W/B
0- Disabled 1 - Battery 16 - UV32 - Temperature 64 - Humidity128 - LuxDefault 241 = 1 + 16 + 32 + 64 + 128, means all enable.
Rev. 0.6
(Param 102) Automatic Report Checklist 2
Checklist 2 for automatic timed report. When the corresponding item is selected,it will be checked when timeoutsetting by Param112.
Parameter NumberSize (Byte) Available Settings Default value Property
0x66 1 1|16|32|64|128 0 R/W/B
0- Disabled 1 - Battery 16 - UV32 - Temperature 64 - Humidity128 - LuxMax value 241 = 1 + 16 + 32 + 64 + 128, means all enable.
(Param 103) Automatic Report Checklist 3
Checklist 3 for automatic timed report. When the corresponding item is selected,it will be checked when timeoutsetting by Param113.
Parameter NumberSize (Byte) Available Settings Default value Property
0x67 1 1|16|32|64|128 0 R/W/B
0- Disabled 1 - Battery 16 - UV32 - Temperature 64 - Humidity128 - LuxMax value 241 = 1 + 16 + 32 + 64 + 128, means all enable.
20
Page 22
(Param 111) Automatic Checklist 1 Interval Time
Interval time set in seconds to check the checklist1’s items. Multilevel Sensor Report will be sent when timeout.
Parameter NumberSize (Byte) Available Settings Default value Property
0x6F 2 30~65535 3600 R/W/U
(Param 112) Automatic Checklist 2 Interval Time
Interval time set in seconds to check the checklist2’s items. Multilevel Sensor Report will be sent when timeout.
Parameter NumberSize (Byte) Available Settings Default value Property
0x70 2 30~65535 3600 R/W/U
(Param 113) Automatic Checklist 3 Interval Time
Rev. 0.6
Interval time set in seconds to check the checklist3’s items. Multilevel Sensor Report will be sent when timeout.
Parameter NumberSize (Byte) Available Settings Default value Property
0x71 2 30~65535 3600 R/W/U
(Param 201) Temperature Offset Value
Can add or minus this setting value to calibrate temperature when checked. Scale is defined by Param64. e.g. Value 15 means 1.5C or 1.5F.
Parameter NumberSize (Byte) Available Settings Default value Property
0xC9 2 -200 ~200 0 R/W/S
(Param 202) Humidity Offset Value
Can add or minus this setting value to calibrate humidity when checked. Unit: %.
Parameter NumberSize (Byte) Available Settings Default value Property
0xCA 1 -100~100 0 R/W/S
(Param 203) Lux Offset Value
Can add or minus this setting value to calibrate Lux when checked.
Parameter NumberSize (Byte) Available Settings Default value Property
0xCB 2 -10000~10000 0 R/W/S
(Param 204) UV Offset Value
Can add or minus this setting value to calibrate UV when checked.
Parameter NumberSize (Byte) Available Settings Default value Property
0xCC 1 -10~10 0 R/W/S
Multilevel Sensor Report will be sent when timeout.
21
Page 23
Rev. 0.6
12 Security Network
This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages tocommunicate to other security enabled Z-Wave Plus products.
The device supports the security function with S0 and S2 encrypted communication. The device will auto switch to the security mode when thedevice included with a security controller.In the security mode, the commands will usesecurity and security2 commandclass wrapped to communicate withothers, otherwise the device will not responseany commands.
This device supports security levels are listed in below table:
SecurityLevels
SECURITY_KEY_S0Yes
SECURITY_KEY_S2_UNAUTHENTICATEDYes
SECURITY_KEY_S2_AUTHENTICATEDYes
SECURITY_KEY_S2_ACCESSNo
Support(Yes/No)
13 SmartStart
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. You can find the QR code on the bottom of the product, like this:
The DSK information will be like this:03904-29465-27012-32844-35506-05493-46416-50723
14 Specifications
Power Supply CR123A × 2 or USB powered
Sleep Current27uA
Wakeup Current 16mA
Action Current30mA
22
Page 24
0m for
Inclusion/Exclusion Current35mA
Power LEDRGB LED
Temperature Sensor-10°C to 50°C / 14°F to 122°F with accuracy of ±0.5°C