AEOTEC Aeon Labs Home Energy Meter Gen5 USER MANUAL

Aeon Labs Home Energy Meter Gen5
(Z-Wave
Home Energy Meter Gen5
Page 1
Change history
Revision Date Change Description
1 9/01/2016 Initial draft.
2 10/10/2016 Update
3
4
5
Page 2
Aeon Labs Home Energy Meter Gen5
Engineering Specifications and Advanced Functions for Developers
Aeon Labs Home Energy Meter is a energy meter for the entire home. It can wirelessly report
instantaneous Power, KWH, Voltage and Amperage measurements to Z-Wave
gateway/controller. It can send Z-Wave REPORTS at any time when it receives Z-Wave Get
Commands.
The HEM can be setup to send automatic reports to any associated nodes in association
group 1 at an interval time
It can be included and operated in any Z-Wave network with other Z-Wave certified devices
from other manufacturers and/or other applications. All non-battery operated nodes within the
network will act as repeaters regardless of vendor to increase reliability of the network.
It is a security enabled Z-Wave plus device supports the Security Command Class and has the
AES-128 bit security encryption built right in. While a Security enabled Controller is needed in
order to fully use the security feature.
It also supports the Over The Air (OTA) feature for the product’s firmware upgrade.
As soon as the HEM is removed from a Z-Wave network it will be reset to default factory
settings.
1. Library and Command Classes
1.1 SDK: 6.51.09
1.2 Library
Basic Device Class: BASIC_TYPE_ROUTING_SLAVE
Generic Device class: GENERIC_TYPE_METER
Specific Device Class: SPECIFIC_TYPE_SIMPLE_METER
1.3 Commands Class
Non- Security Network Security Network
Node Info
Frame
COMMAND_CLASS_ZWAVEPLUS_INFO V2
COMMAND_CLASS_VERSION V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC V2
COMMAND_CLASS_METER V4
COMMAND_CLASS_CRC_16_ENCAP V1
COMMAND_CLASS_MULTI_CHANNEL V4
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION V3
COMMAND_CLASS_CONFIGURATION V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO V1
COMMAND_CLASS_ASSOCIATION V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD V2
COMMAND_CLASS_POWERLEVEL V1
COMMAND_CLASS_SECURITY V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY V1
COMMAND_CLASS_MARK V1
COMMAND_CLASS_ZWAVEPLUS_INFO V2
COMMAND_CLASS_VERSION V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC V2
COMMAND_CLASS_SECURITY V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY V1
COMMAND_CLASS_MARK V1
Page 3
Security
-
Command
Supported
Report
Frame
2. Technical specifications
Operating distance: Up to 492 feet/150 meters outdoors.
Input: 230V~, 50Hz, 10mA (EU/AU Version, 3P4)
380V~, 50Hz, 10mA (EU/AU Version, 3P3)
Measure range of current: 0A to 200A.
Operating temperature: 0 to 40
Relative humidity: 8% to 80%.
.
COMMAND_CLASS_VERSION V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC V2
COMMAND_CLASS_METER V4
COMMAND_CLASS_CRC_16_ENCAP V1
COMMAND_CLASS_MULTI_CHANNEL V4
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
_V3
COMMAND_CLASS_CONFIGURATION V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO V1
COMMAND_CLASS_ASSOCIATION V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD V2
COMMAND_CLASS_POWERLEVEL V1
3. Familiarize yourself with your HEM
3.1 Interface
Page 4
4. All functions of each trigger
4.1 Function of Z-Wave Button
Trigger Description
Click one
time
Add HEM G5 into an existing Z-Wave Network(Non-security):
1.
Power on the HEM, the LED will blink slowly.
2. Let the primary controller into inclusion mode (If you don’t know how to do
this, refer to its manual).
3. Press the Action Button.
4. If the inclusion is success, the LED will be solid. If the LED still blinks slowly,
please repeat the process from step 2.
Remove HEM G5 from an existing Z-Wave Network:
1.
Power on the HEM, the LED will be solid.
2. Let the primary controller of existing Z-Wave network into remove mode (If
you don’t know how to do this, refer to its manual).
3. Press the Action Button.
4. If the removing is success, the LED will blink slowly. If the LED is still solid,
please repeat the process from step 2.
Click 2 times Add HEM G5 into an existing Z-Wave Network(Security):
1.
Power on the HEM, the LED will blink slowly.
2. Let the primary controller into inclusion mode (If you don’t know how to do
this, refer to its manual).
3. Press the Action Button.
4. If the inclusion is success, the LED will be solid. If the LED still blinks slowly,
please repeat the process from step 2.
Remove HEM G5 from an existing Z-Wave Network:
1.
Power on the HEM, the LED will be solid.
2. Let the primary controller of existing Z-Wave network into remove mode (If
Page 5
Press and
hold 10
seconds
you don’t know how to do this, refer to its manual).
3. Press the Action Button.
4. If the removing is success, the LED will blink slowly. If the LED is still solid,
please repeat the process from step 2.
Reset HEM G5 to Factory Default:
1
. Make sure the HEM G5 has been connected to the power supply.
2. Press and hold the Action Button for 10 seconds.
3. If the LED starts slow blinking, which indicates the reset is success, otherwise
please repeat the process from step 2.
Note:
1.
This procedure should only be used when the primary controller is
missing or inoperable.
2. Reset HEM G5 to factory default settings will:
a), exclude the HEM G5 from the Z-Wave network;
b), delete the Association setting, power measure value;
c). restore the configuration settings to the default.
5. Special rule of each command
5.1 Basic Command Class
No Basic mapping is defined for the Device Type. Any received Basic commands will be
ignored.
5.2 Association Command Class
The HEM supports 1 association group and can add max 5 association nodes in
association group 1. Automatic REPORTs (configured via parameter 101/102/103) can be
sent to the associated nodes in association group 1.
5.3 Association Group Info Command Class
5.3.1 Association Group Info Report Command Class
Profile: General: NA (Profile MSB=0, Profile LSB=1)
5.3.2 Association Group Name Report Command Class
Group 1: Lifeline
5.4 Multi Channel Command Class
1. For HEM 1 phase version, the Multi Channel Command supports 1 end point, which
corresponding to clamp 1.
Page 6
Default
2. For HEM 2 phase version, the Multi Channel Command supports 2 end points, which
corresponding to 2 clamps.
Clamp 1= Endpoint 1.
Clamp 2= Endpoint 2.
3. For HEM 3 phase version, the Multi Channel Command supports 3 end points, which
corresponding to 3 clamps.
Clamp 1= Endpoint 1.
Clamp 2= Endpoint 2.
Clamp 3= Endpoint 3.
The Multi Channel CC encapsulates Meter Command Class, which can get the
measurement of Watt (W or kVar), KWH or kVarh, Voltage and Current from the clamps.
5.5 Z-Wave Plus Info Report Command Class
Parameter Value
Z-Wave Plus Version 1
Role Type 5 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON)
Node Type 0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE)
Installer Icon Type 0x1000 (ICON_TYPE_GENERIC_SUB_ENERGY_METER)
User Icon Type 0x1000 (ICON_TYPE_GENERIC_SUB_ENERGY_METER)
5.7 Configuration Command Class
7 6 5 4 3 2 1 0
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Parameter Number
Reserved Size
Configuration Value 1(MSB)
Configuration Value 2
Configuration Value n(LSB)
Parameter Number Definitions (8 bit):
Parameter
Description Default Value Size
Number
………
Page 7
2 For parameters of 101 - 103, power, energy detection
mode configuration:
0 = Report power, energy absolute value;
1 = Report positive/negative power, report the
algebraic sum energy;
2 = Report positive/negative power, only report energy
positive part (consuming electricity);
3 = Report positive/negative power, only report energy
negative part (generating electricity).
3 Enable selective reporting only when power change
reaches a certain threshold or percentage set in 4-11
below. This is used to reduce network traffic.
0 = Disable
1 = Enable
4 Threshold change in wattage to induce an automatic
report (Whole HEM). (Valid values 0-60000)
5 Threshold change in wattage to induce an automatic
report (Clamp 1). (Valid values 0-60000)
6 Threshold change in wattage to induce an automatic
report (Clamp 2). (Valid values 0-60000)
7 Threshold change in wattage to induce an automatic
report (Clamp 3). (Valid values 0-60000)
8 Percentage change in wattage to induce an automatic
report (Whole HEM). (Valid values 0-100)
9 Percentage change in wattage to induce a automatic
report (Clamp 1. (Valid values 0-100)
0 1
1 1
50(W) 2
50(W) 2
50(W) 2
50(W) 2
10 (%) 1
10 (%) 1
10 Percentage change in wattage to induce an automatic
10 (%) 1
report (Clamp 2). (Valid values 0-100)
11 Percentage change in wattage to induce an automatic
10 (%) 1
report (Clamp 3). (Valid values 0-100)
13 Enable /disable reporting CRC-16 Encapsulation
1 1
Command.
0 = Disable
1 = Enable
100 Set 101-103 to default. N/A 1
101 Configure which report needs to be sent in Report
0x00 00 00 02 4
group 1 (See flags in table below).
102 Configure which report needs to be sent in Report
0x00 00 00 01 4
group 2 (See flags in table below).
Page 8
103 Configure which report needs to be sent in Report
group 3 (See flags in table below).
110
Set 111-113 to default.
111 Set the interval time of sending report in Report group
1 (Valid values 0x01-0x7FFFFFFF).
112 Set the interval time of sending report in Report group
2 (Valid values 0x01-0x7FFFFFFF).
113 Set the interval time of sending report in Report group
3 (Valid values 0x01-0x7FFFFFFF).
200 Partner ID
0 = Aeon Labs Standard Product
1 = Others
252 Enable/disable to lock configuration parameters
0 = Disable
1 = Enable.
255 1. Value=0x55555555Default=1Size=4
Reset to factory default setting and removed from the
z-wave network
2. Reset to factory default setting N/A 1
0 4
N/A 1
0x00 00 00 05 4
0x00 00 00 78 4
0x00 00 00 78 4
0 1
0 1
N/A 4
Configuration Values for parameter 101-103
7 6 5 4 3 2 1 0
Configuration
Value 1(MSB)
Configuration
Value 2
Configuration
Value 3
Reserved Multi
Channel
Meter
REPORT (A)
on Clamp 3
Reserved Multi
Channel
Meter
REPORT
(kWh) on
Clamp 3
Multi
Channel
Meter
REPORT (A)
on Clamp 2
Multi
Channel
Meter
REPORT
(kWh) on
Clamp 2
Reserved
Multi
Channel
Meter
REPORT (A)
on Clamp 1
Multi
Channel
Meter
REPORT
(kWh) on
Clamp 1
Multi
Channel
Meter
REPORT (V)
on Clamp 3
Multi
Channel
Meter
REPORT
(Watt) on
Clamp 3
Multi
Channel
Meter
REPORT (V)
on Clamp 2
Multi
Channel
Meter
REPORT
(Watt) on
Clamp 2
Multi
Channel
Meter
REPORT (V)
on Clamp 1
Multi
Channel
Meter
REPORT
(Watt) on
Clamp 1
Page 9
Configuration
Value 4(LSB)
Reserved Reserved Reserved Meter
REPORT (A)
of whole
Clamps
Meter
REPORT (V)
of whole
Clamps
Meter
REPORT
(Watt) of
whole
Clamps
Meter
REPORT
(kWh) of
whole
Clamps
Page 10
Loading...