![](/html/e0/e0db/e0dbf416ac70b1aacdb380cb9ce8d9c6c42c6f7afa74061c75261349fbb101e4/bg1.png)
View the expanded manual:
http://aeotec.com/support
GEN5
Aeotec by Aeon Labs Door/Window Sensor.
1
The Aeotec by Aeon Labs Door/Window Sensor Gen5 provides
your Z-Wave network with the intelligence required for a modern
home automation and security system. And it does it all in a
smaller, more elegant design crafted to suit any home's decor.
The Door Window Sensor is also a security Z-wave device that
supports Over The Air (OTA) for rmware updates.
Familiarize yourself with your Door/Window
2
Sensor.
Package contents:
1. Sensor Unit.
2. Bidirectional Mount Plate.
3. Magnet Unit.
4. Magnet Unit Outer Shell.
5. AAA Batteries(×2).
6. Double-Sided Mounting Tape(×6).
7. Screws(×4).
1 2 3 6 754
LED Latch Button
Orientation Dimples
Magnet Unit
Outer Sehll
Security Tamper
Switch Hole
Screw HolesHitchHitch Hole
Magnet Unit
Action Button
Security Tamper Switch
Battery Holder
Double-Sided Mounting
Tape Sticking Area
Quick start.
3
The installation of your Door Window Sensor has two major
steps: the Main Sensor and the Magnet. Your Door Window
Sensor will use wireless technology to talk to your Z-Wave
network once paired to your Z-Wave network.
Selecting where you'll place your Door/Window Sensor in your
home is just as important as the actual afxing it to the surface.
Whether it’s for security or intelligence purposes, your sensor:
1.
Should be affixed indoors and away from sources of
moisture.
2.
Placed within 30 meters of another Z-Wave device that is
either a gateway or not powered by batteries.
3.
The magnet and the main sensor must be less than 2cm
apart. Main sensor must be afxed to the door or window
and the magnet must be afxed to the frame. The magnet
and the main sensor must separate when the door or
window is opened.
4.
Should not be mounted on a metal frame.
Afx your Sensor plates to a surface.
The Mounting plates can be affixed using screws or doublesided tape.
If you are using screws, attach both mounting plates to the
respective surface using the two 20mm screws provided.
If you are using double-sided tape, wipe the two surfaces clean
of any oil or dust with a damp towel. When the surface has
completely dried, peel one side of the tape back and attach it
to the corresponding section on the rear side of the mounting
plates.
Adding your Sensor to your Z-Wave network
With your mounting plates prepared to hold each component of
your sensor, it’s time to add it to your Z-Wave network.
1.
Let your Z-Wave primary controller/gateway enter into
adding/inclusion mode.
2.
Take your Sensor near to your primary controller.
3.
Press the Action Button once on your Sensor.
4.
If your Door Window Sensor has been successfully added
to your Z-Wave network, its Status LED will fast blink for 2
seconds and then be solid for 2 seconds when you press the
Action Button again. If the adding was unsuccessful and the
Status LED continues to fast blink for 8 seconds and then
slow blink for 3 seconds, repeat the above steps.
With your Door Window Sensor now working as a part of
your smart home, you’ll be able to congure it from your home
control software or phone application. Please refer to your
software’s user guide for precise instructions on configuring
Door Window Sensor to your needs.
.
Attach your sensor to its plates.
With your sensor added to your Z-Wave network, it's now time
to insert each main part of your sensor into the corresponding
sensor plate.
1.
Insert the larger of your two sensor parts into the large
mounting plate ensuring that the dlmple on the front is on the
same side as the smaller mounting plate.
2.
lnsert the smaller of your two sensor parts into its mounting
plate.
Advanced functions.
4
Send a wake up notification.
In order to send your Sensor new configuration commands
from your Z-Wave controller or gateway, it will need to be woken
up.
1.2.Remove your Sensor unit from its Back Mounting Plate, press
the Action Button on the back of the Sensor unit and then
release the Action Button. This will trigger and send a wake
up notication command to your controller/gateway.
If you want your Sensor to keep awake for a longer time,
press and hold the Action Button on the back of the Sensor
unit for 3 seconds, then your Sensor will wake up for 10
minutes and the Status LED will fast blink while it is awake.
Removing your Sensor from your Z-Wave network.
Your sensor can be removed from your Z-Wave network at any
time. You'll need to use your Z-Wave network's main controller/
![](/html/e0/e0db/e0dbf416ac70b1aacdb380cb9ce8d9c6c42c6f7afa74061c75261349fbb101e4/bg2.png)
gateway. To do this, please refer to the part of their respective
manuals that tell you how to remove devices from your network.
1.
Put your primary controller into device removal mode.
2.
Unlock your Sensor from the Back Mount plate and take the
Sensor unit near to your primary controller.
3.
Press the Action Button on your Sensor.
4.
If your Door Window Sensor has been successfully removed
from your Z-Wave network, its Status LED will fast blink for 8
seconds and then slow blink for 3 seconds when you press
the Action Button again. If the removing was unsuccessful,
the Status LED will fast blink for 2 seconds and then be solid
for 2 seconds when you press the Action Button, repeat the
above steps.
Security or Non-security feature of your Sensor in Z-wave
network.
Including Door/Window Sensor as a non-secure device:
If you want your Sensor as a non-security device in your Z-wave
network, you just need to press the Action Button once on Door
Window Sensor when you use a controller/gateway to add/
include your Sensor.
Including Door/Window Sensor as a secure device:
In order to take full advantage of all functionality the Door
Window Sensor, you may want your Sensor is a security device
that uses secure/encrypted message to communicate in Z-wave
network, so a security enabled controller/gateway is needed
for the Door Window Sensor to be used as a security device.
You need to press the Sensor’s Action Button 2 times within
1 second when your security controller/gateway starts the
network inclusion.
Factory Reset your Sensor.
If your primary controller is missing or inoperable, you may
wish to reset all of your Door Window Sensor’s settings to their
factory defaults. To do this, press and hold the Action Button
for 20 seconds and Status LED will be solid for 2 seconds to
conrm a success.
Technical specifications.
5
Model number: ZW120.
Battery: Up to 1 year battery life with 2×AAA batteries.
Operating temperature: 0°C to 40°C.
Relative humidity: 8% to 80%.
Operating distance: Up to 300 feet/100 metres outdoors.
Warranty.
6
Aeon Labs warrants to the original purchaser of Products that
for the Warranty Period (as dened below), the Products will be
free from material defects in materials and workmanship. The
foregoing warranty is subject to the proper installation, operation
and maintenance of the Products in accordance with installation
instructions and the operating manual supplied to Customer.
Warranty claims must be made by Customer in writing within
thirty (30) days of the manifestation of a problem. Aeon Labs'
sole obligation under the foregoing warranty is, at Aeon Labs'
option, to repair, replace or correct any such defect that was
present at the time of delivery, or to remove the Products and to
refund the purchase price to Customer.
The "Warranty Period" begins on the date the Products is
delivered and continues for 12 months.
Any repairs under this warranty must be conducted by an
authorized Aeon Labs service representative and under Aeon
Labs' RMA policy. Any repairs conducted by unauthorized
persons shall void this warranty.
Excluded from the warranty are problems due to accidents, acts
of God, civil or military authority, civil disturbance, war, strikes,
fires, other catastrophes, misuse, misapplication, storage
damage, negligence, electrical power problems, or modication
to the Products or its components.
Aeon Labs does not authorize any person or party to assume or
create for it any other obligation or liability in connection with the
Products except as set forth herein.
Aeon Labs will pass on to Customer all manufacturers’ Material
warranties to the extent that they are transferable, but will not
independently warrant any Material.
Customer must prepay shipping and transportation charges for
returned Products, and insure the shipment or accept the risk of
loss or damage during such shipment and transportation. Aeon
Labs will ship the repaired or replacement products to Customer
freight prepaid.
Customer shall indemnify, defend, and hold Aeon Labs
and Aeon Labs' affiliates, shareholders, directors, officers,
employees, contractors, agents and other representatives
harmless from all demands, claims, actions, causes of action,
proceedings, suits, assessments, losses, damages, liabilities,
settlements, judgments, fines, penalties, interest, costs and
expenses (including fees and disbursements of counsel) of every
kind (i) based upon personal injury or death or injury to property
to the extent any of the foregoing is proximately caused either
by a defective product (including strict liability in tort) or by the
negligent or willful acts or omissions of Customer or its ofcers,
employees, subcontractors or agents, and/or (ii) arising from or
relating to any actual or alleged infringement or misappropriation
of any patent, trademark, mask work, copyright, trade secret or
any actual or alleged violation of any other intellectual property
rights arising from or in connection with the products, except
to the extent that such infringement exists as a result of Aeon
Labs' manufacturing processes.
IN NO EVENT SHALL AEON LABS BE LIABLE FOR
ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF
PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER
OR ANY THIRD PARTY, WHETHER IN AN ACTION IN
CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED
OF THE POSSIBILITY OF SUCH DAMAGES. AEON LABS'
LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY
CAUSE OF ACTION ARISING IN CONNECTION WITH THIS
AGREEMENT OR THE SALE OR USE OF THE PRODUCTS,
WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY,
BREACH OF WARRANTY, BREACH OF AGREEMENT, OR
EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED TO, AT
AEON LABS' OPTION, REPLACEMENT OF, OR REPAYMENT
OF THE PURCHASE PRICE FOR THAT PORTION OF
PRODUCTS WITH RESPECT TO WHICH DAMAGES
ARE CLAIMED. ALL CLAIMS OF ANY KIND ARISING IN
CONNECTION WITH THIS AGREEMENT OR THE SALE OR
USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS
MADE IN WRITING WITHIN THIRTY (30) DAYS FROM AEON
LABS'S DELIVERY, OR THE DATE FIXED FOR DELIVERY IN
THE EVENT OF NONDELIVERY.
THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE
AND IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES,
WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
FCC NOTICE (for USA)
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY
RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED
MODIFICATIONS TO THIS EQUIPMENT.SUCH
MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO
OPERATE THE EQUIPMENT.
STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY
LOCATIONS. DO NOT IMMERSE IN WATER. NOT FOR USE
WHERE DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions:
This device may not cause harmful interference, and
1.
This device must accept any interference received, including
2.
interference that may cause undesired operation. This equipment
has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of
the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician
for help.
Warning
Do not dispose of electrical appliances as unsorted municipal
waste, use separate collection facilities.
Contact your local government for information regarding the
collection systems available.
Version:501012000001-X01 www.aeotec.com