Aeon Labs DSC19103 User Manual

Aeon Labs Micro Smart Energy Illuminator
(In-Wall Z-Wave Dimmer Module w/ Energy Monitor)
Introduction:
The Aeon Labs Micro Smart Energy Illuminator is a low-cost
Z-Wave dimmer module specifically used to enable Z-Wave
command and control (on/off/dim) for existing in-wall
consumption or kWh energy usage over a period of time.
The wireless module is powered from the mains supply and
is a three-wire design which requires a neutral connection.
In the event of power failure, non-volatile memory retains
all programmed information relating to the units operating
status.
It also is a repeater in the Z-Wave network. Acting as a
bridge for communication, it will forward Z-Wave command
messages to their destinations if the originating controller is
out of range from the destination node.
By taking advantage of the Z-Wave mesh network,
commands can be routed to their destination via
intermediary “listening” Z-Wave products. Products that
are Z-Wave certified can be used and communicate with
other Z-Wave certified devices.
- 1 - - 2 - - 3 - - 4 -
In-Wall Electrical Installation Instructions
IMPORTANT: A licensed electrician with knowledge and
understanding of electrical systems and electrical safety
should complete the electrical installation inside the main
circuit box (usually located outside of your house).
IMPORTANT:
during installation for safety and to ensure that wires are
not shortcircuited during insallation which will cause
damage to the Micro Module.
The Aeon Labs Micro Smart Energy Illuminator must first be
powered by a 3-wire system in order to operate. The wiring
diagram is as follows:
Z-Wave Network Instructions:
The Aeon Labs Micro Smart Energy Illuminator must be
paired (included) into a Z-Wave network before it can
receive Z-Wave commands to turn on/off/dim and report
its energy usage. The Smart Energy Illuminator can only
communicate to devices within it’s own Z-Wave network.
Note: The LED on the Micro Smart Energy Illuminator will
blink if it is currently not paired into a Z-Wave network.
The electricity to the circuit must be shut off
:
Adding/Including/Pairing the Micro Smart Energy
Illuminator into a Z-Wave Network
1. Press the button labeled “Include” on the Aeon Labs
Minimote to begin the Z-Wave inclusion process.
Note: To include the Aeon Labs Micro Smart Energy
Illuminator with other controllers, please consult the
operation manual for these controllers on how to
include Z-Wave products into an existing network.
For instructions on select partner gateways, visit
www.aeon-labs.com/support.
2. While the Micro Smart Energy Illuminator is powered
in a 3-wire system, press the button located near the
Status Indication LED. Or alternatively, the external
switch/button control can be pressed 6 times in quick
succession.
Troubleshooting: If the Aeon Labs Micro Smart Energy
Illuminator was not successfully included into any Z-Wave
network, the LED will be blinking slowly continually. If the
Aeon Labs Micro Smart Energy Illuminator was successfully
included to a Z-Wave network, the Status Indication LED will
either be solid on or off (depending on if the switch is on or
off) 10 seconds after the button was last pressed.
Removing/Resetting the Micro Smart Energy
Illuminator from your Z-Wave Network
1. Press the button labeled “Remove” on the Aeon Labs
Minimote Stick to begin the Z-Wave removal process.
Note: To include the Aeon Labs Micro Smart Energy
Illuminator with other controllers, please consult the
operation manual for these controllers on how to
include Z-Wave products into an existing network.
For instructions on select partner gateways, visit
www.aeon-labs.com/support.
2. While the Micro Smart Energy Illuminator is powered
in a 3-wire system, press the button located near the
Status Indication LED. Or alternatively, the external
switch/button control can be pressed 6 times in quick
succession.
Troubleshooting: If the Aeon Labs Micro Smart Energy
Illuminator was removed from the Z-Wave network, the
Status Indication LED will be blinking. If the Aeon Labs
Smart Energy Illuminator was not successfully removed
from the Z-Wave network, the Status Indication LED will
either be solid on or off (depending on if the switch is on or
off) 10 seconds after the button was last pressed.
Turning On/Off/Dim the Micro Smart Energy
Illuminator
Use any of the below methods to turn on/off or dim the
power through the Micro Smart Energy Illuminator.
o Pressing the button on the external (Wall)
switch will be able to toggle power flow (on/off)
through the Smart Energy Illuminator (2-state
flip/flop switch). If the mode of the micro
module is set to momentary push button,
holding the push button will dim the lights and a
short press will toggle the lights between on/off.
o Through the usage of Z-Wave commands built
Caution: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
into Z-Wave certified controllers and gateways.
(The specific Z-Wave commands supporting this
function are the Basic Command Class and
Multilevel Switch Command Class.) Please
consult the operation manual for these
controllers for specific instructions on
controlling the Smart Energy Illuminator.
o A short press on the button of the Smart Energy
Illuminator will toggle the lights (on/off) while
holding this button will dim the lights.
Change Mode on the External Switch/Button Control
The Aeon Labs Micro Smart Energy Illuminator by default is
set to be controlled via 2-state (flip/flop) external wall
switch. Pushing the button 6 times in quick succession on
the Micro Smart Energy Illuminator will swap between this
default mode and the momentary push button external wall
switch mode.
Monitoring Energy Consumption
The Aeon Labs Micro Smart Energy Illuminator can report
wattage energy usage or kWh energy usage to a Z-Wave
gateway or controller when requested. If this function is
supported by the gateway/controller, the energy
consumption will be displayed in the user interface of the
gateway/controller. (The specific Z-Wave commands
supporting energy monitoring are the Meter Command
Class and Multilevel Sensor Command Class.) Please
consult the operation manual for these
gateways/controllers for specific instructions on monitoring
the Smart Energy Illuminator.
Technical Specifications
o USA: 110V 60Hz input, 275W or 2.5A max output
o EU/AU: 230V 50Hz input, 575W or 2.5A max output
Warranty
Aeon Labs warrants to the original purchaser of Products
that for the Warranty Period (as defined below), the
Products will be free from material defects in materials and
workmanship. The foregoing warranty is subject to the
proper installation, operation and maintenance of the
Products in accordance with installation instructions and
the operating manual supplied to Customer. Warranty
claims must be made by Customer in writing within thirty
(30) days of the manifestation of a problem. Aeon Labs' sole
obligation under the foregoing warranty is, at Aeon Labs'
option, to repair, replace or correct any such defect that
was present at the time of delivery, or to remove the
Products and to refund the purchase price to Customer.
The "Warranty Period" begins on the date the Products is
delivered and continues for 12 months.
Any repairs under this warranty must be conducted by an
authorized Aeon Labs service representative and under
Aeon Labs’ RMA policy. Any repairs conducted by
unauthorized persons shall void this warranty.
Excluded from the warranty are problems due to accidents,
acts of God, civil or military authority, civil disturbance, war,
strikes, fires, other catastrophes, misuse, misapplication,
storage damage, negligence, electrical power problems, or
modification to the Products or its components.
Aeon Labs does not authorize any person or party to
assume or create for it any other obligation or liability in
connection with the Products except as set forth herein.
Aeon Labs will pass on to Customer all manufacturers’
Material warranties to the extent that they are transferable,
but will not independently warrant any Material.
Customer must prepay shipping and transportation charges
for returned Products, and insure the shipment or accept
the risk of loss or damage during such shipment and
transportation. Aeon Labs will ship the repaired or
replacement products to Customer freight prepaid.
Customer shall indemnify, defend, and hold Aeon Labs and
Aeon Labs’ affiliates, shareholders, directors, officers,
employees, contractors, agents and other representatives
harmless from all demands, claims, actions, causes of action,
proceedings, suits, assessments, losses, damages, liabilities,
settlements, judgments, fines, penalties, interest, costs and
expenses (including fees and disbursements of counsel) of
every kind (i) based upon personal injury or death or injury
to property to the extent any of the foregoing is
proximately caused either by a defective product (including
strict liability in tort) or by the negligent or willful acts or
omissions of Customer or its officers, employees,
subcontractors or agents, and/or (ii) arising from or relating
to any actual or alleged infringement or misappropriation of
any patent, trademark, mask work, copyright, trade secret
or any actual or alleged violation of any other intellectual
property rights arising from or in connection with the
products, except to the extent that such infringement exists
as a result of Aeon Labs‘ manufacturing processes.
IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY
INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR
CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF
PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER OR
ANY THIRD PARTY, WHETHER IN AN ACTION IN CONTRACT,
OR TORT, OR OTHERWISE EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. AEON LABS’ LIABILITY
AND CUSTOMER’S EXCLUSIVE REMEDY FOR ANY CAUSE OF
ACTION ARISING IN CONNECTION WITH THIS AGREEMENT
OR THE SALE OR USE OF THE PRODUCTS, WHETHER BASED
ON NEGLIGENCE, STRICT LIABILITY, BREACH OF WARRANTY,
BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, IS
EXPRESSLY LIMITED TO, AT AEON LABS’ OPTION,
REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE
PRICE FOR THAT PORTION OF PRODUCTS WITH RESPECT TO
WHICH DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY KIND
ARISING IN CONNECTION WITH THIS AGREEMENT OR THE
SALE OR USE OF PRODUCTS SHALL BE DEEMED WAIVED
UNLESS MADE IN WRITING WITHIN THIRTY (30) DAYS
FROM AEON LABS’S DELIVERY, OR THE DATE FIXED FOR
DELIVERY IN THE EVENT OF NONDELIVERY.
THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE
AND IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES,
WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
FCC NOTICE (for USA):
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO
OR TV INTERFERENCE CAUSED BY UNAUTHORIZED
MODIFICATIONS TO THIS EQUIPMENT. SUCH
MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO
OPERATE THE EQUIPMENT.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received,
including interference that may cause undesired
operation. This equipment has been tested and found
to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However,
there is no guarantee that interference will not occur
in a particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning the
equipment off and on, the user is encouraged to try
to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment
and receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV
technician for help.
Warning:
Do not dispose of electrical appliances as unsorted
municipal waste, use separate collection facilities.
Contact your local government for information regarding
the collection systems available.
Certifications (regional):
Harmonizing the Smart Home.
www.aeon-labs.com
- 5 - - 6 - - 7 - - 8 -
Loading...