Aemc instruments MN122 User Manual

AC Current Probe Model MN122
User Manual
DESCRIPTION
The MN122 (Catalog #2129.11) is a current probe for tight areas such as crowded wiring. Extends DMM AC measurements to 150A plug.
WARNING
These safety warnings are provided to ensure the safety of personnel and proper operation of the instrument.
• Read the instruction manual completely and follow all the safety information before attempting to use or service this instrument.
• Use caution on any circuit: Potentially high voltages and currents may be present and may pose a shock hazard.
• Read the Safety Specifications section prior to using the current probe. Never exceed the maximum voltage ratings given.
• Safety is the responsibility of the operator.
• ALWAYS connect the current probe to the display device before clamping the probe onto the sample being tested.
• ALWAYS inspect the instrument, probe, probe cable, and output terminals prior to use. Replace any defective parts immediately.
• NEVER use the current probe on electrical conductors rated above 300V in overvoltage category III (CAT III). Use only on insulated conductors.
INTERNATIONAL ELECTRICAL SYMBOLS
This symbol signifies that the current probe is protected by double or reinforced insulation. Use only factory specified replacement parts when servicing the instrument.
This symbol signifies CAUTION! and requests that the user refer to the user manual before using the instrument.
This is a type B current sensor. Do not apply around or remove from HAZARDOUS LIVE conductors without additional protective means (de-energizing the circuit or wearing protective clothing suitable for high voltage work).
In conformity with WEEE 2002/96/EC
RECEIVING YOUR SHIPMENT
Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage.
PACKAGING
The AC Current Probe MN122 is shipped with this instruction manual and a product warranty and registration card.
INSTRUMENT COMPATIBILITY
The Model MN122 is compatible with any ammeter, multimeter, or other current measuring instruments with an input impedance of less than 5Ω. To achieve the stated accuracy, use the MN122 with a meter having an accuracy of 0.75% or better. The accuracy of the meter must be added to the probe accuracy.
AC. The Model MN122 offers a 5 ft lead with safety 4mm banana
1.36" (35mm)
0.87" (22mm)
Ø =0.43" max
(11mm)
4.53" (115mm)
Black
Red
1.4" (36mm)