AEMC Instruments 2137.77 User manual

Page 1
n
Power Adapter for PEL
n
Adaptateur secteur pour PEL
POWER ADAPTER
Models PEL 102 & PEL 103
ENGLISH
FRANÇAIS
User Manual
Notice de Fonctionnement
www.GlobalTestSupply.com
Page 2
Copyright © Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments. All rights reserved.
No part of this documentation may be reproduced in any form or by any means (including electronic storage and retrieval or translation into any other language) without prior agreement and written consent from Chauvin Arnoux®, Inc., as governed by United States and International copyright laws.
This documentation is provided “as is,” without warranty of any kind, express, implied, or otherwise. Chauvin Arnoux®, Inc. has made every reasonable effort to ensure that this documentation is accurate; but does not warrant the accuracy or completeness of the text, graphics, or other information contained in this documentation. Chauvin Arnoux®, Inc. shall not be liable for any damages, special, indirect, incidental, or inconsequential; including (but not limited to) physical, emotional or
monetary damages due to lost revenues or lost prots that may result from the use of this documentation, whether or not
the user of the documentation has been advised of the possibility of such damages.
www.GlobalTestSupply.com
Page 3
Table of Contents
ENGLISH
Ordering Information .....................................................................................2
Use .............................................................................................................2
Specications ................................................................................................2
Maintenance ..................................................................................................2
FRANÇAIS
Pour Commander ..........................................................................................4
Utilisation .......................................................................................................4
Caractéristiques Techniques .........................................................................4
Maintenance ..................................................................................................4
www.GlobalTestSupply.com
Page 4
ORDERING INFORMATION
PEL Power Adapter for use with Model PEL102 and PEL103 ..............................................Cat. #2137.77
USE
The power adapter is used to supply the device when it is used for an extended period. The internal battery of the PEL remains charged, enabling the device to continue to operate in the event of a power outage up to a half-hour.
■ Connect the adapter to the voltage inputs of the PEL.
■ Connect the C7 plug to the input of the PEL.
■ Connect the voltage and the current inputs of the PEL as if the adapter were not there. The L1 and N or L1 and L2 voltage inputs must be connected for the adapter to operate. The adapter can operate only on 50/60Hz networks (not DC or 400Hz).
SPECIFICATIONS
Electrical
Range of use Phase-to-neutral voltage: 110 to 277Vac
Max. input voltage Permanent: 530Vac; Transient: 550Vac Min. input voltage 85Vac (-20%) Max. output voltage 360V peak Frequency 50/60Hz Consumption 100VA max at 50/60Hz
Environmental
Operation: 32 to 122°F (0 to 50°C) and 10 to 85% RH Storage: -4 to 158°F (-20 to +70°C) and 0 to 95% RH Indoor use; Level of pollution: 2 Altitude: < 2000m; Storage: < 10,000m
Mechanical
Dimensions (L x H x D): 3.6 x 2.6 x 1.5" (93 x 67 x 37mm) Weight: 5 oz (150g) approx Cord: 11" (300cm) approx Inrush protection: IP 40 per IEC 60529 IK 04 per IEC 50102 Drop Test: 1 meter
Electromagnetic compatibility: Emissions and immunity in an industrial setting compliant with IEC 61326-1
Specications are subject to change without notice.
Phase-to-phase voltage: 110 to 480Vac
MAINTENANCE
This instrument contains no parts that can be replaced by personnel who have not been specially trained and accredited. Any unauthorized repair or replacement of a part by an equivalent may impair safety.
Cleaning: Disconnect anything connected to the device. Clean it with a soft cloth moistened with soapy water. Wipe dry completely.
Repair: For all repairs, please contact the factory or your local distributor.
2 PEL Power Adapter
www.GlobalTestSupply.com
Page 5
www.GlobalTestSupply.com
Page 6
POUR COMMANDER
Adaptateur PEL pour modèle PEL102 et PEL103 .................................................................Cat. #2137.77
UTILISATION
L’adaptateur secteur sert à alimenter l’appareil lorsqu’il est utilisé sur une longue durée. Ainsi la batterie interne du PEL reste chargée et l’appareil peut continuer à fonctionner en cas de coupure secteur de moins d’une demi-heure.
■ Connectez l’adaptateur sur les entrées tension du PEL.
■ Connectez la prise C7 sur l’entrée du PEL.
■ Branchez ensuite les entrées tension et les entrées courant du PEL comme si l’adaptateur n’était pas
présent.
Les entrées tension L1 et N ou L1 et L2 doivent impérativement être branchées pour que l’adaptateur fonctionne.
L’adaptateur ne fonctionne que sur des réseaux à 50 ou 60Hz (pas sur du continu ni sur du 400 Hz).
CARACTÉRISTIQUES TECHNIQUES
Electrical
Domaine d’utilisation Tension phase neutre : 110 à 277 Vac
Tension d’entrée max. Permanente : 530 Vac; Transitoire : 550 Vac Tension d’entrée min. 85V Tension de sortie max. 360 V crête Fréquence 50/60Hz Consommation 100 VA max à 50 ou 60 Hz
Conditions d’environnement
Domaine de fonctionnement : 0 à 50 °C et 10 à 85%HR Domaine de stockage : -20 à +70°C et 0 à 95%HR Utilisation en intérieur.; Degré de pollution : 2. Altitude : < 2 000 m; Stockage : < 10 000 m.
Caractéristiques constructives
Dimensions (L x h x P) : 93 x 67 x 37 mm Masse : 150 g environ Cordon : 30 cm environ Indice de protection : IP 40 selon IEC 60529 IK 04 selon IEC 50102 Chute : 1 mètre.
Compatibilité électromagnétique: Émission et immunité en milieu industriel selon IEC 61326-1.
Les spécications sont sujets à modication sans préavis.
Tension entre phases : 110 à 480 Vac
ac (-20%)
MAINTENANCE
L’appareil ne comporte aucune pièce susceptible d’être remplacée par un personnel non formé et non agréé. Toute intervention non agréée ou tout remplacement de pièce par des équivalences risque de compromettre gravement la sécurité.
Nettoyage: Déconnectez tout branchement de l’appareil. Nettoyez-le avec un chiffon doux légèrement imbibé d’eau savonneuse.
Réparations: Pour les réparations sous garantie et hors garantie, contactez votre agence commerciale Chauvin Arnoux la plus proche ou votre centre technique régional Manumesure qui établira un dossier de retour et vous communiquera la procédure à suivre.
4 PEL Power Adapter
www.GlobalTestSupply.com
Page 7
POWER ADAPTER
For use only with
Models PEL 102 & PEL 103
V1 V2 V3 N
1000V CAT III 600V CAT IV
POWER & ENERGY LOGGER
ON /OFF
START/STOP
REC
I1 I2 I3
OL
PEL Power Adapter
www.GlobalTestSupply.com
5
Page 8
10/14
99-MAN 100411 v1
®