AEMC Instruments 1000-24-2-1 User manual

Page 1
AmpFlex® Flexible AC Current Probes
USER MANUAL
ON OL
600V CAT IV
10 mV/A
1 mV/A
OFF
AmpFlex
®
®
INSTRUMENTS
www.GlobalTestSupply.com
Page 2
Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards.
We guarantee that at the time of shipping your instrument has met its published specifications.
An NIST traceable certificate may be requested at the time of purchase, or obtained by returning the instrument to our repair and calibration facility, for a nominal charge.
The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer.
 
Serial #:
Catalog #:
Model #:
Please fill in the appropriate date as indicated:
Date Received:
Date Calibration Due:
_____________________________________
AmpFlex® AC Current Probe
www.GlobalTestSupply.com
Page 3
Table of Contents
Warning ..................................................................................................... 2
International Electrical Symbols ................................................................ 2
Definition of Measurement Categories ...................................................... 3
Receiving Your Shipment .......................................................................... 3
Packaging .................................................................................................. 3
Description ................................................................................................ 4
Features .................................................................................................... 5
Features .................................................................................................... 6
Accessories ............................................................................................... 6
Standard Models ....................................................................................... 7
Specifications ............................................................................................ 8
Instrument Compatibility .......................................................................... 12
Operation ................................................................................................. 12
Making Measurements with the AmpFlex® .......................................... 12
Tips for Making Precise Measurements: ............................................. 12
Typical Response Curves: ................................................................... 16
Maintenance ............................................................................................ 18
Warning ............................................................................................... 18
Battery Replacement ........................................................................... 18
Cleaning............................................................................................... 18
www.GlobalTestSupply.com
Page 4
AmpFlex® - Flexible AC Current Probes
Warning
These safety wa rnings a re p rovided t o en sure the safety of personnel and proper operation of the instrument.
Read the in struction ma nual completely and foll ow all the
safety inform ation befo re attempting to use o r servi ce this instrument.
Wear protective clothing and gloves as required.
Use ca ution on any circu it: potentially high voltag es an d
currents may be present and may pose a shock hazard.
Read the safety spe cifications section prio r to using th e
current probe. Never exceed the max voltage ratings given.
Safety is the responsi bility of the operator. T he A mpFlex
must be used only by qu alified p ersonnel u sing a pplicable safety precautions.
ALWAYS de-energize the c ircuit before wrapping the
AmpFlex parts. Do not wrap on live conductors.
ALWAYS c onnect the elec tronic module to the dis play
device before wrap ping t he AmpFl ex being tested.
ALWAYS inspec t the module, sens or, s ensor cable, and
output termin als pri or to u se. Repl ace any defective parts immediately. Use only factory parts.
NEVER us e the AmpFlex
above 600V CAT IV; 1000V CAT III.
®
around b are conductors, b us ba rs, or near live
®
aro und th e sample
®
on ele ctrical conductors rated
®
International Electrical Symbols
This symbol signifies that the current probe is p rotected by double or reinforced insulation. Use o nly factory spe cified repla cement parts when servicing the instrument.
This symbol signifies CAUTION! and requests that the user refer to the user manual before using the instrument.
This symbol refers to a type B current sensor. Do not apply around or remove from HAZARDOUS LIVE conductors without additional protective means (de-energizing the circuit or wearing protective clothing suitable for high voltage work).
- 2 -
www.GlobalTestSupply.com
Page 5
AmpFlex® - Flexible AC Current Probes
Definition of Measurement Categories
CAT I: For measurements on circuits not directly connected to the A C
supply wall o utlet su ch as prot ected se condaries, si gnal level, and limited energy circuits.
CAT II: For mea surements pe rformed on ci rcuits directly co nnected to
the ele ctrical distri bution system. Exa mples are m easurements on household appliances or portable tools.
CAT III: For me asurements p erformed in the building in stallation at the
distribution l evel su ch a s on h ardwired e quipment in fixed installation and circuit breakers.
CAT IV: For me asurements p erformed at the primary ele ctrical supply
(<1000V) such as on p rimary ove rcurrent protection devi ces, ripple control units, or meters
Receiving Your Shipment
Upon receiving you r shipment, ma ke sure that the contents a re consistent wi th the packin g list. Noti fy your di stributor of any mi ssing items. If the equipment appears to be damaged, file a claim immediately with the carrier a nd notify your di stributor at on ce, giving a detailed description of any damage.
Packaging
Your AmpFlex® consists of the following items:
Flexible probe with electronic module
User manual
9V battery
- 3 -
www.GlobalTestSupply.com
Page 6
AmpFlex® - Flexible AC Current Probes
Description
The AmpFlex® is a flexible AC current transformer composed of a flexible sensor a nd an electronic m odule. The flexib le sen sor permits measurements on condu ctors where standard clamp-on probe s could not be used. In pa rticular, it can be installed in ti ght spaces, around breaker panels, around cable bundles, around wide or large bus bars, or even wrapp ed arou nd irregula r sh apes. The Shap e Memory feature enables the user to “pre-shape” the sensor before inserting it between or around conductors. This feature facilitates closing, enhances user safety, and all eviates the drooping effe ct ty pically a ssociated with flexible sensors.
®
The AmpFle x standard t ransformers. Th e tran sformation pri nciple is ba sed on an ai r core. It presents virtually no load to the system u nder te st, has a low phase shift a nd excellent frequ ency response, and cannot be damaged by overloads.
The se nsor assembly is waterproof and insul ated for 600V CAT IV; 1000V CAT III. The AmpFl ex designed wit h material s a nd co mponents to meet internatio nal agency approvals.
The Amp Flex for direct readings on DMMs, data l oggers, oscilloscopes, and power or harmonic meters. TRMS measurements are taken when connected to a TRMS m eter. The Amp Flex AC component of the measured signal is measured.
The length of the flexible sensor can be selected in lengths of 24" , 36", and 48" in le ngth. Consult the factor y for custom lengths, ranges and/or features.
is lightwe ight and do es not u se magneti c co res like
®
meets EN 61010-1, is CE m arked, and is
®
ha s a n mV output proportional to th e current m easured
®
is in sensitive to DC currents an d only the
- 4 -
www.GlobalTestSupply.com
Page 7
AmpFlex®
AmpFlex® - Flexible AC Current Probes
600V CAT IV
®
Figure 1
1. Positive: Red Banana Plug (+)
2. Common: Black Banana Plug (-)
3. Power ON Indicator (Green LED)
4. Overload Indicator (Red LED)
5. Range Selection Switch
®
6. AmpFlex
Connector/Latch
www.GlobalTestSupply.com
7. Flexible Sensor (Diameter 0.5", 12.5mm)
8. Lead from Sensor to Module (6.5 ft, 2m)
9. Electronic Module - Descriptive Label on Back
Case (range, model, etc.)
- 5 -
Page 8
AmpFlex® - Flexible AC Current Probes
Features
Models to measure from 0.5Arms to 30,000Arms
Accuracy 1% of Reading
TRMS measurements when connected to a TRMS instrument
No core saturation or damage if overloaded
Overrange LED for measurement circuitry
600V CAT IV; 1000V CAT III; EN 61010; CE Mark
Wate rproof sensor
9V battery for typical 150 hour continuous operation
Shape Memory for custom pre-shaping of sensor before use
(no drooping)
Very high frequency response
Low phase shift for power
Insensitive to DC, measures only AC component on DC + AC signals
Excellent linearity
Lightweight
Accessories
Banana (Female) / BNC (Male) Adapter ..................... Cat. # 2118.46
®
For connection of the AmpFlex
BNC terminals on scopes and other displaying instruments.
to SLII Models L101, L102, L562,
- 6 -
www.GlobalTestSupply.com
Page 9
AmpFlex® - Flexible AC Current Probes
Standard Models
Model
300-24-2-10 30/300A 100/10mV/A 24” (610mm) 8” (190mm) 2112.88 1000-24-1-1 1000A 1mV/A 24” (610mm) 8” (190mm) 2112.39 1000-24-2-1 100/1000A 10/1mV/A 24” (610mm) 8” (190mm) 2112.98 1000-36-2-1 100/1000A 10/1mV/A 36” (910mm) 11” (290mm) 2113.00
3000-24-2-0.3 300/3000 A 3.3/0.3mV/A 24” (610mm) 8” (190mm) 2114.87*
3000-24-1-1 3000A 1mV/A 24” (610mm) 8” (190mm) 2112.46 3000-36-1-1 3000A 1mV/A 36” (910mm) 11” (290mm) 2112.48 3000-24-2-1 300/3000A 10/1mV/A 24” (610mm) 8” (190mm) 2113.05 3000-36-2-1 300/3000A 10/1mV/A 36” (910mm) 11” (290mm) 2112.00 3000-48-2-1 300/3000A 10/1mV/A 48” (1220mm) 15” (390mm) 2112.01
6000-36-2-0.1 600/6000 A 1/0.1mV/A 36” (910mm) 11” (290mm) 2113.21
30000-24-2-0.1 3000/30 ,000A 1/0.1mV/A 24” (610mm) 8” (190mm) 2113.33
Measurement
Range
Output
Sensor Length
*This model (Cat. #2114.87) is recommended to be used with our Simple Logger® II Models L101, L102 & L562.
All of our AmpFlex® models are designed to be used with recorders or power analyzers with a voltage AC input. A scale factor may need to be entered into the recorder to display the exact value.
Max
Conductor
Size
Cat. #
- 7 -
www.GlobalTestSupply.com
Page 10
AmpFlex® - Flexible AC Current Probes
Specifications
Model 300A 30/300A 1000A 100/1000A
Measurement
Range
Accuracy ±1% +200mA ±1% +200mA ±1% +200mA ±1% +200mA
Output Signal 10mV/A
Crest Factor
(mid-range)
Phase Shift @
50/60Hz
Residual Noise 200mA 200mA 200mA 200mA
Model # 3000A 300/3000A 3000/30000A 600/6000A
Measurement
Range
Accuracy ±1% +200mA ±1% +200mA ±1% +1A ±1% +500mA
Output Signal 1mV/A
Crest Factor
(mid-range) Phase Shift
@ 50/60Hz
Residual Noise 200mA 200mA 1A 500mA
*Reference Conditions: 25°C ± 5°K, 20 to 75% RH, 1 minute warm-up, battery at 9V ± 0.5V, conductor center, external DC magnetic field < 40A/m, no external AC magnetic field, no external electrical field, 10 to 100Hz, sine wave. See accuracy curves for low currents.
5 to 300A 5 to 300A 5 to 1000A 5 to 1000A
100mV/A or
10mV/A
3.0 3.0 9.0 9.0
1.5° 1.3° 0.7° 0.7°
5 to 3000A 5 to 3000A 5-30000A 5 to 6000A
10mV/A or
1mV/A
3.0 3.0 3.0 > 10
0.7° 0.7° 0.5° 0.5°
1mV/A
1mV/A or
0.1mV/A
10mV/A or
1mV/A
1mV/A or
0.1mV/A
- 8 -
www.GlobalTestSupply.com
Page 11
AmpFlex® - Flexible AC Current Probes
Common Specifications
ELECTRICAL Accuracy: 1% of reading ± residual noise Frequency Range: 10 - 20,000Hz with current derating Signal Output: 4.5V max Working Voltage: 600V CAT IV; 1000V CAT III Frequency Influence:
See Accuracy vs. Frequency curves on pages 18 and 19
Frequency Limitation:
See current derating curves (note no limitation on 300A Range) page 19
Influence of adjacent conductor in contact with sensor and with AC signal: 0.2% typical, 2% maximum
Influence of conductor position in sensor: 0.5% typical, 4% max Influence of shape of sensor: Oblong shape: 0.2% typical, 1% max Common Mode Rejection: 100dB typical, 80dB min
ENVIRONMENTAL SPECIFICATIONS Operating Temperature Range: -14° to 131°F (-10° to +55°C) Storage Temperature Range: -40° to 158°F (-40° to +70°C) Influence of Temperature:
Sensor: -14° to 194°F (-10° to 90°C); 0.15% per 18°F (10°C) typical,
0.5% per 18°F 10°C max Module: -14° to 131°F (-10° to 55°C); 0.15% per 18°F (10°C) typical,
0.5% per 18°F (10°C) max
Influence of Relative Humidity:
10 to 90% RH: 0.2% typical, 0.5% maximum
Operating Relative Humidity:
50° to 86°F (10° to 30°C); 85° ± 5% RH (without condensation) 104° to 122°F (40° to 50°C); 45° ± 5% RH (without condensation)
Altitude:
Operating: 0 to 2000m, working voltage derating above Non-operating: 0 to 12,000m
- 9 -
www.GlobalTestSupply.com
Page 12
AmpFlex® - Flexible AC Current Probes
MECHANICAL SPECIFICATIONS Module Output: Two 4 mm safety banana jacks
Standard 3/4" (19mm) spacing
Battery: 9V Alkaline (NEDA 1604A, IEC 6LR61) recommended Battery Life: Useable from 9V to 7V, 150 hours typical (continuous use) Low Battery: Power ON indicator (green LED) when battery voltage
7V, LED blinks when battery voltage is low
Overload Indication: Red LED ON indicates the selected range is
overloaded. Module output may not reflect the actual measurement
Dimensions (sensor):
24", 36", 48" & 60" nominal (± 1"), other lengths optional
Dimensions (Electronic Module): 4.9 x 2.5 x 1.1" (124 x 64 x 28mm) Weight:
AmpFlex AmpFlex AmpFlex AmpFlex
®
48" with battery: 0.95 lb
®
60" with battery: 1.13 lb
®
24" with battery: 0.74 lb
®
36" with battery: 0.89 lb
Connection Cable Length (sensor to module): 6.5 ft (2m) Colors: Red sensor with dark gray connector and module, black
connection cable (sensor to module)
Drop Test: Per IEC 68-2-32 Vibration: Per IEC 68-2-6 Mechanical Shock: Per IEC 68-2-27 Weatherproofing: Module: IP40 (EN 60529)
Sensor: IP 45 (EN60529)
SENSOR SPECIFICATIONS: Weight: 10.8oz (302.4g) Bend Radius: 0.75" (19mm) minimum Bending Life: >10000 without performance deterioration Waterproofing: IP 65 Resistance to Chemicals: Resistant to oils and aliphatic hydrocarbons
- 10 -
www.GlobalTestSupply.com
Page 13
AmpFlex® - Flexible AC Current Probes
Diameter: 12mm ± 0.5mm Outer Sheath Material: Polyurethane, UL94V0 Dielectric Strength: 7500V Latch Spring Life: >10,000 maneuvers
MATERIAL SPECIFICATIONS Module:
UL 94V2, Color dark gray, Polycarbonate
Sensor Latch:
Material: Lexan 500R, UL94V0
Cable Assembly to Sensor:
UL 94V0, 1000V rating
SAFETY SPECIFICATIONS
Electrical:
Double insulation or reinforced insulation between primary or secondary and outer case per EN 61010
600V CAT IV; 1000V CAT III Pollution Degree 2
7.50kV, 50/60Hz, dielectric between secondary and the outer case
Electromagnetic Compatibility
Immunity: meets BF EN 61326-1 Industrial environment category
- Electrostatic discharge (meets EN 61000-4-2) 8kV in air – level 3 – class B 4kV on contact – level 2 – class B
- 10V/m radiated electromagnetic field (in line with EN 61000-4-3) – class B
- Rapid transients (in line with EN 61000-4-4) 1kV – level 2 – class B
- Electric shocks (in line with EN 61000-4-5) 6kV – class B
- 11 -
www.GlobalTestSupply.com
Page 14
AmpFlex® - Flexible AC Current Probes
Instrument Compatibility
The AmpFle x® is compatible with any mu ltimeter, AC voltmeter, or other voltage measu ring instrument with an input im pedance greater than 1M . To a chieve the be st overall accu racy, u se the AmpF lex
®
with a AC voltmeter having an accuracy of 0.75% or better.
Operation
Please make sure that yo u have alre ady read an d fully understa nd the WARNING section on page 2.
Making Measurements with the AmpFlex®:
Connect the electroni c module to t he AC Volt rang e of your DM M or
measuring in strument. Select the a ppropriate module output volt age range. If the current magnitude is un known, and if AmpFlex ranges, select the lowest mV/A output setting.
Wrap the flex ible core around the conductor to be t ested. If po ssible
within range, select the higher mV/A AmpFlex
®
output range to obt ain the best re solution. Do n ot exceed specified cu rrent rang e for the output. Do not use on selected range if overload LED goes on.
Read the displayed valu e on the DM M and divid e it by the range
selected (i.e. if reading = 2.59V with the 10mV/A output ra nge, the current flowing through the probe is 2590mV ÷ 10 = 259A).
For best a ccuracy, ca refully cent er the co nductor in side the flexi ble
core, and av oid if possibl e, the prox imity of other cond uctors which may create noise and interference (particularly near the latch).
True RMS measurements a re obtai ned when t he Amp Flex
connected to a True RMS meter. Note that the DC component is not measured.
Tips for Making Precise Measurements:
When u sing the AmpFlex® with a m eter, it is impo rtant to sel ect the
range that provides the best resolution. Failure to do this may result in measurement errors.
®
For b est results, sel ect t he hig hest A mpFlex
and the most sensitive meter range for this output.
Make sure the DMM or measuring instrument can accurately measure
AC. Certai n inexpensive DMM h ave poor resolution and accuracy
mV when measuring low mV AC.
For best accura cy, center the AmpFle x
®
measured. (See figure 2).
out put sig nal p ossible
aroun d the con ductor to be
®
has two
®
is
- 12 -
www.GlobalTestSupply.com
Page 15
AmpFlex® - Flexible AC Current Probes
®
Tips for Making Precise Measurements (continued):
To increase the sensitivity or mea sure on low currents, the AmpFlex®
may be wrap ped several t imes around the con ductor. Remember to
divide your reading by the number of turns for the actual measurement (see Figure 4).
The ove rall measurement accura cy i s the sum of the AmpFl ex
accuracy and the displaying instrument accuracy.
!
ON OL
600V CAT IV
10 mV/A
1 mV/A
OFF
AmpFlex
®
®
INSTRUMENTS
®
For best accuracy center the Ampflex
Figure 2
- 13 -
www.GlobalTestSupply.com
Page 16
AmpFlex® - Flexible AC Current Probes
Tips for Making Precise Measurements (continued):
The AmpFlex® may be doubled around the conductor to be measured to double the output. (See Figures 3 and 4 to show the different values on a DMM while measuring 250A
AC.)
250.0 MV
250 A
ACV DCV
COM
ON OL
600V CAT IV
10 mV/A
1 mV/A
OFF
AmpFlex
®
®
INSTRUMENTS
+
!
One turn around a conductor carrying 250AAC
Figure 3
- 14 -
www.GlobalTestSupply.com
Page 17
AmpFlex® - Flexible AC Current Probes
Tips for Making Precise Measurements (continued):
500.0 MV
ACV DCV
250 A
COM
+
!
ON OL
600V CAT IV
10 mV/A 1 mV/A OFF
®
®
INSTRUMENTS
Double the turns to double the output in low current applications or for higher sensitivity
www.GlobalTestSupply.com
Figure 4
- 15 -
Page 18
AmpFlex® - Flexible AC Current Probes
Typical Response Curves:
Typical Accuracy % vs. Frequency @ 100 A, 1 mV/A Output
0.00 %
-0.50 %
-1.00 %
-1.50 %
-2.00 %
-2.50 %
-3.00 %
1 Hz 10 Hz 100 Hz 1000 Hz 10 kHz 100 kHz
Frequency
Typical Accuracy % vs. Frequency @ 100 A, 10 mV/A
0.00 %
-1.00 %
-2.00 %
-3.00 %
-4.00 %
-5.00 %
-6.00 %
-7.00 %
1 Hz 10 Hz 100 Hz 1000 Hz 10 kHz
Frequency
100 kHz
%
± 10
± 9
± 8
± 7
± 6
± 5
± 4
± 3
± 2
± 1
± 0
0.1 A 0.5 A 1 A 5 A 10 A 100 A
Typical Accuracy % per Range to 100 A
20 A ... 3000 A
www.GlobalTestSupply.com
Amps
- 16 -
10 kA ... 30 kA
Page 19
AmpFlex® - Flexible AC Current Probes
Typical Response Curves (cont.):
-5¡
-10¡
Degrees
-15¡
-20¡
-25¡
Typical Phase Shift vs. Frequency @ 200 A, 1 mV/A Output
1 Hz 10 Hz 100 Hz 1000 Hz 10 kHz 100 kHz
Frequency
3000 A
2500 A
2000 A
1500 A
Amps
1000 A
500 A
0 A
1000 Hz 10 kHz 100 kHz
Current Derating Curve (I < 3000 A)
Frequency
Current Derating Curve (I > 3000 A)
30 kA
25 kA
20 kA
15 kA
Amps
10 kA
5 kA
0 A
100 Hz 1000 Hz 10 kHz 100 kHz
Frequency
- 17 -
www.GlobalTestSupply.com
Page 20
AmpFlex® - Flexible AC Current Probes
Maintenance
Warning
For maintenance use only specified replacement parts.
To avoi d el ectrical shock, do not attempt to p erform a ny servicing
unless you are qualified to do so.
®
Do not perform any service while the AmpFlex
To avoid electrical shock and/or damage to the in strument, do not get
water or other foreign agents into the electronic module.
Also see warning on page 2.
Battery Replacement
If the powe r ON in dicator (g reen LE D) blinks o r does not lig ht up,
replace the battery.
®
Remove the AmpFlex
from any circuit before replacing the battery.
To replace the battery, open re ar case, replace b attery an d
reassemble. The gre en LED should go on when the module is t urned
on.
Cleaning
It is importan t to keep the probe sensor latch matin g su rfaces clean
and prevent foreign bo dies from hampering the cl osing. The se nsor may be gently cleaned with a soft cloth, soa p and wate r. Dry immediately after cleaning. Avoid water penetration i nto the electronic module.
Make sure the sensor, electronic module, and all l eads are dry before
any further use.
is on any circuit.
- 18 -
www.GlobalTestSupply.com
Page 21
www.GlobalTestSupply.com
Page 22
Limited Warranty
The AmpFlex® Probe is warranted to the owner for a period of 1 year from the date of o riginal purcha se against de fects in manu facture. This limited warranty is given by AEM C was purchase d. This warranty is vo id if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC
Instruments.
Full warranty coverage and product registration is available on our website at: www.aemc.com/warranty.html.
Please print the online Warranty Coverage Information for your records.
What AEMC
®
Instruments will do:
If a malfunction occurs within the one-y ear period, y ou may return the instrument to us for repair, provided we have your warranty registration information on file or a proof of purchase. AEMC option, repair or replace the faulty material.
   
®
Instruments, not by the distributor from whom it
®
I nstruments w ill, at its
®
Warranty Repairs
What you must do to return an Instrument for Warranty Repair:
First, request a Customer Service Authorization Number (CSA#) by phone or by fa x from o ur Service De partment (see address be low), then retur n the instrument along w ith the s igned CSA Form. Please write the CSA# on the outside of the shipping c ontainer. Return the instrument, postage or shipment pre-paid to:
Chauvin Arnoux
®
, Inc. d.b.a. AEMC® Instruments
15 Faraday Drive • Dover, NH 03820 USA Tel: (800) 945-2362 (Ext. 360)
(603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309
repair@aemc. com
Caution: To protect yourself against in-transit loss, w e recomme nd you
insure your returned material.
NOTE: You must obtain a CSA# before returning any instrument.
www.GlobalTestSupply.com
Page 23
www.GlobalTestSupply.com
Page 24
Chauvin Arnoux®, Inc. d.b.a AEMC® Instruments
99-MAN 100122 v18 01/15
www.GlobalTestSupply.com
Loading...