![](/html/03/0386/03866bf19199f40343f1f8da7dc3205aecd1effac36041b126c254e18831fc85/bg1.png)
AC Current Probe
Model SR604
The Model SR604 is designed for use
in industrial and utility environments.
The unique ergonomic design allows it
to easily clamp onto cables or small
bus bars. It is built to the highest safety
and performance standards including
the CE Mark and is UL approved for
Canada and United States.
Excellent transformation and low
phase shift, plus a broad frequency
response, permit accurate measurements of current for power and power
quality measurements. The high
quality magnetic cores and uniform
windings provide sensitivity for very
low level current measurements, as
well as measurements up to 1200A
The Model SR604 works as a
traditional current transformer (with
a ratio of 1000:1) and provides current
outputs in mA/A for use on DMMs,
power and harmonic meters, data
loggers, recorders or instruments with
current ranges.
Technical Assistance (800) 343-1391 www.aemc.com 1 of 4
a c .
Features
• Measurement range of
100mA to 1200A
• Large jaw opening accommodates
conductors up to two 500MCM
conductors
• Ergonomic design and easy
operation
• Conforms to EN 61010, 600V Cat. III
safety standard
• Low phase shift for power
measurements
• Available with mA output signals
• Designed for DMMs, recorders,
loggers, oscilloscopes, power and
harmonic meters
• ULapprovedforCanadaand
United States
• DoubleInsulation
• CE Mark
a c
Applications
• Power quality measuring
• Low industrial loads
• Measuring around cable bundles
• Power load monitoring
• Waveform analysis
SR604_211344 (pdf) 0308 Rev. 05
![](/html/03/0386/03866bf19199f40343f1f8da7dc3205aecd1effac36041b126c254e18831fc85/bg2.png)
Specifications
MODEL SR604*
ELECTRICAL
Nominal Range 1000A
Measurement Range 0.1 to 1200A
Transformation Ratio 1000: 1
Output Signal 1mA
Accuracy (1000A Range)
0.1 to 10A ≤ 3% + 0.1A
50A 1.5% of Reading
200A 0.75% of Reading
1000A 0.5% of Reading
1200A 0.5% of Reading
Phase Shift (1000A Range)
50A 1.5°
200A 0.75°
1000A 0.5°
1200A 0.5°
Overload 1200A for 40 min ON, 20 min OFF
Frequency Range 30Hz to 5kHz; current derating
above 1kHz using the formula:
1000A x 1/F (in kHz)
Load Impedance 5Ω max
Working/Common
Mode Voltage
Output Termination Lead
MECHANICAL
Operating Temperature -14° to 122°F (-10° to 50°C)
Storage Temperature -4° to 158°F (-20° to 70°C)
Operating Relative
Humidity
Jaw Opening 2.25" (57mm) max
Maximum Conductor Size 2.05" (52mm)
Maximum Bus Bar Size One 1.95 x 0.19" (50 x 5mm)
Dimensions 4.37 x 8.50 x 1.77" (111 x 216 x 45mm)
Weight 1.21 lbs (550g)
Polycarbonate Material Handles: Polycarbonate + ABS, Gray, UL94 V0. Jaws: Polycarbonate, Red, UL94 V0
SAFETY
Electrical EN 61010-2-032
UL Approval Yes – Canada and United States
Double Insulation
Yes
CE Mark Yes
Note: Reference conditions: 23 ± 3°K, 20 to 75% RH, 48 to 65Hz, external magnetic field < 40A/m, no DC component, no external current
carrying conductor, test sample centered. Load impedance 0.2Ω @ lead < 40mΩ for 250A range.
*Diode Protection for open secondary (Output)
a c /Aa c : (1Aa c @ 1000A)
600V Cat. III
0 to 85% @ 35°C
SR604_211344 (pdf) 0308 Rev. 05
Technical Assistance (800) 343-1391 www.aemc.com 2 of 4