Small classic tool bag, three MiniFlex® MA193-10-BK
sensors, 5 ft USB cable, four black test leads and
alligator clips, power cord,
twelve color-coded ID
markers, Multifix mounting
system, safety data sheet,
compliance sheet, SD-Card
with USB-SD-Card reader,
quick start user guide, and
USB stick supplied with
DataView
user manual.
®
software and
FEATURES
• Simple-to-use, single-, dual- (split-phase) and three-phase
(Y, ∆) power & energy loggers
• Designed to work in 1000V CAT III and 600V CAT IV
environments and fits in many distribution panels
• Power measurements: VA, W and var
• Energy measurements: VAh, Wh (source, load) and varh
(quadrant indication)
®
• Updated features in DataView
real-time communication with a PC and report generation
with pre-defined or user defined templates
• USB, LAN, Ethernet and Bluetooth
(Class 1 wireless communication, up to 300 ft away)
• Satisfies the monitoring requirements of NEC Code 220.87
• AC/DC Current Probe, Model J93, is available for measuring
current up to 5000A
dc & 3500Aac
• Power adapter allows the PEL 102 to be powered from a
phase measurement input
• Provides all the necessary functions for power and energy
data logging for 50Hz, 60Hz, 400Hz and DC distribution
systems
• Automatic recognition of the connected current
sensors/probes
software for configuring
www.aemc.com
Technical Assistance (800) 343-1391
Page 2
Model PEL 103
A
T
I
N
A
F
E
T
TM
Large Functional Displays
Measurement ModeInformation Mode
IP
54
Rated
Y
S
R
G
ETHERNET
FEATURES
• Simple-to-use, single-, dual- (split-phase)
and three-phase (Y, ∆) power & energy loggers
• Designed to work in 1000V CAT III and 600V CAT IV
environments and fits in many distribution panels
• Power measurements: VA, W and var
• Energy measurements: VAh, Wh
(source, load) and varh (quadrant indication)
®
• Updated features in DataView
real-time communication with a PC and report
generation with pre-defined or user defined templates
• USB, LAN, Ethernet and Bluetooth
(Class 1 wireless communication, up to 300 ft away)
• Satisfies the monitoring requirements
of NEC Code 220.87
• PEL 103 can be configured from front panel, DataView
control panel or the FREE Android™ application
• AC/DC Current Probe, Model J93, is available
for measuring current up to 5000A
• Provides all the necessary functions for power
and energy data logging for 50Hz, 60Hz, 400Hz
and DC distribution systems
• Automatic recognition of the connected current
sensors/probes
software for configuring
dc & 3500Aac
Hook up, voltage and current
ratios and aggregation period
can be configured from the front
panel of the PEL 103.
Max ModeHarmonic Mode
Max values for voltage, current
(including neutral current), power
and harmonics.
®
Real-time updates are displayed
for voltage, current, power,
frequency, power factor and
tangent.
Total Harmonic Distortion (THD)
can be displayed by phase or
phase to phase. Neutral current
THD can also be displayed
.
KIT OPTION INCLUDES
PEL 103 Kit
Small classic tool bag, three MiniFlex® MA193-10-BK
sensors, 5 ft USB cable, four black test leads and
alligator clips, power cord,
twelve color-coded ID
markers, Multifix mounting
system, safety data
sheet, compliance sheet,
SD-Card with USB-SDCard reader, quick start
user guide, and USB stick
supplied with DataView
software and user
manual.
®
Technical Assistance (800) 343-1391
www.aemc.com
Page 3
POWER QUALITY ANALYZERS, METERS & LOGGERS
TM
POWER QUALITY ANALYZERS, METERS & LOGGERS
Power & Energy Loggers PEL 100 Series
Three-Phase Power Quality Analyzer
Model PEL 105
Waterproof...great for outdoor use!
IP
67
Rated
Phase
ETHERNET
Powered
KIT OPTION INCLUDES
PEL 105 Kit
Extra-large tool bag, accessory pouch, 5 ft USB cable,
five 10 ft black voltage leads (waterproof cap) with alligator
clips, power adapter 110/230V with US power cord, four
water-tight AmpFlex
#2137.59 only), 9.6V NiMH battery, SD-card, USB SDcard reader, twelve color-coded input ID markers, quick
start guide, and a USB stick supplied with DataView
software and user manual.
®
A196-24-BK (included with Cat.
®
ACCESSORIES
Pole Mounting Kit
Catalog #2137.82 (optional)
Set of two, with hardware
cover closed
FEATURES
• Simple-to-use, single-,
dual- (split-phase) and three-phase
(Y, ∆) power & energy loggers
• Designed to work in 1000V CAT III and 600V CAT IV environments
• Supports 17 different network connections
• Power measurements: VA, W and var
• Energy measurements: VAh, Wh (source, load) and varh
(four quadrant indication)
• Includes DataView
real-time display, analysis and report generation
• USB, LAN, Ethernet, Wi-Fi and Bluetooth communication
(Class 1 wireless communication, up to 300 ft away)
• Satisfies the monitoring requirements of NEC Code 220.87
• PEL 105 can be configured from front panel, DataView
or the FREE Android™ application
• Supports AC/DC Current Probe Model J93
for measuring current up to 5000A
• Provides all the necessary functions for power and energy data logging
for 50Hz, 60Hz, 400Hz and DC distribution systems
• Automatic recognition of the connected current sensors/probes
• Powers directly from phase measurement
• Pole mountable
®
software for configuring,
dc & 3500Aac
NEW!
®
control panel
CATALOG NO.DESCRIPTION
2137.51Power & Energy Logger Model PEL 102 (no LCD w/3 MA193-10-BK Sensors)
2137.52Power & Energy Logger Model PEL 103 (with LCD w/3 MA193-10-BK Sensors)
2137.57Power & Energy Logger Model PEL 105 w/o Sensors (Waterproof IP67)
2137.59Power & Energy Logger Model PEL 105 w/4 A916-24-BK (AmpFlex
2137.61Power & Energy Logger Model PEL 102 (no LCD or Sensors)
2137.62Power & Energy Logger Model PEL 103 (with LCD, no Sensors)
Accessories (Optional)
2137.77Adapter–Power Adapter for use with Models PEL 102 & PEL 103
2137.82Pole Mounting Kit
www.aemc.com
®
– Waterproof IP67)
Technical Assistance (800) 343-1391
Page 4
SPECIFICATIONS
MODELSPEL 102, PEL 103 & PEL 105
GENERAL
Sampling Frequency
Data Storage Rate
Demand Period Storage Rate
Recorded Parameters
(Single- and Poly-Phase)
Event Log
Front Panel Indicator LEDs
Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD Card status
Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f / DPF
Tracks and records status changes and error messages along with recorded data
Storage Capacity
INPUTSVoltage
Current
PEL 102/103 - 3 current input channels ; PEL 105 – 4 input channels via custom 4 pin jacks that accept AEMC® probes and sensors
PEL 102/103 – 3 input channels; PEL 105 – 4 input channels via 4mm safety banana jacks
ELECTRICAL
VOLTAGE MEASUREMENTPEL 102/103 RANGEPEL 105 RANGERESOLUTION/ACCURACY*
42.5 to 69Hz42.5 to 69Hz±0.1Hz
10 to 1000Vrms10 to 1000Vrms0.1V/±0.2% Rdg ± 0.2V
17 to 1700Vrms17 to 1000Vrms0.1 to 1V/±0.2% Rdg ± 0.4V
340 to 460Hz340 to 460Hz
10 to 600Vrms10 to 600Vrms0.1V/±1% Rdg ± 1V
17 to 1200Vrms17 to 1200Vrms0.1 to 1V/±1% Rdg ± 1V
100 to 1000V10 to 1000V0.1V/±1% Rdg ± 3V (typical)
CURRENT MEASUREMENTA193***A196***
Nominal range for current probes
supplied with kit. See chart on
Pages 26 and 27 for other probes
200mA to 3000Arms200mA to 10,000A
CT Ratios
POWER MEASUREMENTS
Active Power (P)*
Reactive Power (Q)*
Apparent Power (S)*
Power Factor
Tangent φ (active/reactive power ratio)
-2 to 2GW0.001W±0.5% Rdg ± 0.005% Pnom
-2 to 2Gvar0.001var±1% Rdg ± 0.01% Qnom
0 to 2GVA0.001VA±0.5% Rdg ± 0.005% Snom
-1 to 10.001± 0.05
-3.2 to 3.20.001± 0.02
ENERGY MEASUREMENTS
Active Energy (EP)
Reactive Energy (EQ)
Apparent Energy (ES)
0 to 4 x 10
0 to 4 x 10
0 to 4 x 10
"
"
"
THD
Individual Harmonics
External Supply
Power From Phase Measurement
PEL 102/103 requires optional Power Adapter Cat #2137.77; PEL 105 Internal up to 1000Vac
Back-Up Power Source/Charge Time
Battery Life
MECHANICAL
Communication Ports
Dimension/Weight
Case
Mounting/Security
Kensington anti-theft system (PEL 102 & PEL 103) / Embedded magnets on back side, keyhole slot on back side
DISPLAY
Display Type for Model PEL 103 / PEL 105
2.63 x 2.16" (67 x 55mm), four line, monochrome, backlit LCD with adjustable brightness and contrast
ENVIRONMENTAL / SAFETY
Operating Temperature/Relative Humidity
Storage Temperature
Safety Rating/CE Rating
Complies with IEC 61010-1:Ed3, and IEC 61010-2-030: Ed1 for 1000V CAT III / 600V CAT IV (PEL 102 & PEL 103)
-4° to 122°F (-20° to 50°C) with batteries; -4° to 158°F (-20° to 70°C without batteries)
Index of Protection
* Maximum value is current probe dependent.
** Computers with Class II Bluetooth will restrict range to 40 ft Computers without Bluetooth will require a Class I or Class II Bluetooth radio adapter.
*** Maximum current reduced by a factor of 2 for 400Hz fundamental frequency.
128 samples per cycle; 50/60Hz (16 samples/cycle 400Hz)
1 per second (200ms also available on PEL 105)
User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 minutes)
V, I, W, VA, var, PF, Tan, Wh, VAh, varh, THD (V and I),
SD card included / SD cards up to 32 GB formatted FAT32 are supported
–
Programmable from 1:1 to 25,000:1 (probe dependent)
1Wh±0.5% Rdg
1varh±2% Rdg
1Vah±0.5% Rdg
± 655%
1 to 50 displayed in percentage; 1 to 7 at 400Hz
110V/250V (10%) @ 50/60Hz; 400Hz
Rechargeable 8.4V NiMH battery pack / Approximately 5 hours
30 minutes minimum, 60 minutes typical
USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class 1 **/ Wi-Fi (PEL 105 only)
10.08 x 4.92 x 1.46" (256 x 125 x 37mm) / 2.20lbs (1kg) (PEL 102 & PEL 103);
9.8 x 7.8 x 2.6" (250 x 200 x 67mm) / 8.8lbs (4kg) (PEL 105)