![](/html/00/0050/0050b6c532ad773694827f618a7c4c65ad6deea16e56485941e311ee8e722587/bg1.png)
Special
product
features
▼
R
O
4
2
C
H
A
N
N
O
E
L
M
OTHER PRODUCTS FROM CHAUVIN ARNOUX® GROUP
PC Oscilloscopes
S
L
Model MTX 162
E
D
T
S
C
1
E
T
E
D
T
R
A
N
E
S
I
E
L
B
D
A
K
C
A
T
S
P
C
C
O
C
N
E
N
Compact, lightweight and stackable,
0
n
s
these instruments can be connected
S
T
N
directly to a PC via USB or Ethernet
I
R
E
C
T
N
O
I
T
SPECIFICATIONS
MODEL MTX 162
INTERFACE
Screen Specifications
Display Mode
Traces on Screen
Screen Control
Color PC screen (min. resolution: 1024 x 768)
8 x 10 div.- Multi-windowing
(control panel, trace, zoom, FFT, etc.)
4 traces + 4 references
Windows-like & online help; All commands available via mouse
IP
30
Rated
VERTICAL
Vertical Sensitivity
Bandwidth
Channels
60MHz (bandwidth limiter: 15MHz, 1.5MHz or 5kHz)
5mV to 100V/div
2 channels, class 1, common ground
HORIZONTAL
Time Base Speed
32 ranges from 5ns to 100s/div
TRIGGER
Mode
Source
Type
Auto, Triggered, One-shot ROLL, Auto-level at 50%
CH1, CH2, Line
Rising or falling edge, adjustable pretriggering from 0 to 100%
DIGITAL MEMORY
Max. Sampling Speed
Vertical Resolution
Memory Capacity
Repetitive = 20GS/s; One-shot = 50MS/s
8 bits
Depth = 50,000 points – storage capacity depends on
PC configuration used
COMMUNICATION
Software
PC operating software and LabWindows/LabView drivers
(included)
SPO (SMART PERSISTENCE OSCILLOSCOPE)
Duration of Persistence
Analog remanent mode
MEASUREMENT PROCESSING
FFT Analyzer/
MATH Functions
Manual Cursors
Automatic
Measurements
dv, dt, 1/dt, phase – cursors linked or unlinked to trace
2 or 19 measurements out of 19 + automatic phase
on/any type of curve markers and limits
FFT, +, -, x, /
RECORDER MODE
▲
Duration/Sampling
Dedicated ROLL mode from 2s to 33min
Connect and view
results directly
from your
PC computer
Real-time trace Typical PC setup screen
CATALOG NO. DESCRIPTION
2150.14 PC Scope Module Model MTX 162UE (2-Channel, 60MHz)
2150.15 PC Scope Module Model MTX 162UEW (2-Channel, Wi-Fi, 60MHz)
www.aemc.com
Technical Assistance (800) 343-1391
![](/html/00/0050/0050b6c532ad773694827f618a7c4c65ad6deea16e56485941e311ee8e722587/bg2.png)
Models MTX 1052 & MTX 1054
IP
30
Rated
FEATURES
• 2-channel/60MHz
(Model MTX 162 software only)
• 2- & 4-channel models/150MHz
(Models MTX 1052 & MTX 1054)
• Oscilloscope with FFT and recorder
• Harmonic analyzer
(Models MTX 1052 & MTX 1054)
• Sampling rate 50MS/s in one-shot mode
and 20GS/s in ETS mode (Model MTX 162)
• Sampling rate 200MS/s in one-shot
mode and 100GS/s in ETS mode
(Models MTX 1052 & MTX 1054)
• Detects 10ns transients
• 8-bit (Model MTX 162) and 10-bit
(Models MTX 1052 & MTX 1054)
A/D converter
• Vertical sensitivities of 250μV-100V/div
(300V CAT II)
• Advanced trigger modes and SPO
(Smart Persistence Oscilloscope) analysis
• Stackable with direct PC connection
via USB or Ethernet
• PC operating software (included) and
LabWindows/LabView drivers with
Windows-like environment
(printing, standard files, etc.)
• Local or remote Ethernet universal
communication
Browse through
Chauvin Arnoux's
Metrix® Test &
►
Measurement Catalog
SPECIFICATIONS
MODELS MTX 1052 / MTX 1054
INTERFACE
Screen Specifications
Display Mode
Traces on Screen
Screen Control
8 x 10 div.- Multi-windowing (control panel, trace, zoom, FFT, etc.)
VERTICAL
Vertical Sensitivity
Bandwidth
Channels
HORIZONTAL
Time Base Speed
TRIGGER
Mode
Source
Type
counting (2 to 16,384 events), TV (525 = NTSC, 625 = PAL/SECAM),
DIGITAL MEMORY
Max. Sampling Speed
Vertical Resolution
Memory Capacity
COMMUNICATION
Software
SPO (SMART PERSISTENCE OSCILLOSCOPE)
Duration of
Persistence
Performance
MEASUREMENT PROCESSING
FFT Analyzer/
MATH Functions
Manual Cursors
Automatic
Measurements
RECORDER MODE
Duration/Sampling
HARMONIC ANALYZER
Analysis Range
Processing
Total RMS value, THD and selected order (%F, phase, frequency, Vrms)
Color PC screen (min. resolution: 1024 x 768)
4 traces + 4 references
Windows-like & online help – all commands available via mouse
2.5mV – 100V/div, up to 250µV/div with vertical expansion
150MHz (bandwidth limiter: 15MHz, 1.5MHz or 5kHz)
2 or 4 channels, class 1, common ground
35 ranges from 1ns to 200s/div
Auto, Triggered, One-shot ROLL, Auto-level at 50%
CH1, CH2, EXT, Line or CH1 to CH4, Line
Edge, Pulse Width or Delay (40ns to 10.5s),
Pre-trigger adjustable from 0 to 100%, Hold-off (40ns to 10.5s)
Repetitive = 100GS/s; One-shot = 200MS/s
10 bits (9 bits used)
Depth = 50,000 points – storage capacity depends
on PC configuration used
PC operating software and LabWindows/LabView drivers included
100ms, 200ms, 500ms, 1s, 2s, 5s, 10s and infinite
Acquisition rate 50k waveforms/s/channel,
no. of samples acquired: 19MS/s/channel
FFT (calculation over 2048 points), + , - ,
x , / – "Made-to-measure" function editor
dv, dt, 1/dt, phase – cursors linked or unlinked to trace
2 or 19 measurements out of 19 + automatic phase
on any type of curve markers and limits
Duration: 2s to 31 days / Sampling interval: 40µs to 53.57s
Fundamental from 40Hz to 1kHz + 31 orders on 1 to 4 channels
CATALOG NO. DESCRIPTION
2150.10 PC Scope Module Model MTX 1052B-PC (2-Channel, 150MHz)
2150.11 PC Scope Module Model MTX 1052BW-PC (2-Channel, Wi-Fi, 150MHz)
2150.12 PC Scope Module Model MTX 1054B-PC (4-Channel, 150MHz)
2150.13 PC Scope Module Model MTX 1054BW-PC (4-Channel, Wi-Fi, 150MHz)
Technical Assistance (800) 343-1391
www.aemc.com