DATA LOGGERS
Simple Logger® II 4-Channel Event
Model L404
Four channel logger tracks
events as they occur
SpecificationS
MODEL L404
ELECTRICAL
Channels
Input Connection
Voltage Range
Input Impedance
Sample Rate
Storage Rate
Storage Mode
Recording Length
Memory
Communication
Power Source
Battery Life
MECHANICAL
Dimensions
(without removable connector)
Weight (with battery)
Case
Vibration
Shock
Drop
One 8-position removable screw-type terminal block
0 to 5V
Maximum of 8 per second
(maximum once every two sample periods)
programmable using DataView
The recorded data is stored in non-volatile memory
and retained even if the battery is low or removed.
USB 2.0 optically isolated
2 x 1.5V AA-cell Alkaline batteries
(dependent on storage rate/recording length)
IEC 68-2-6 (1.5mm, 10 to 55Hz)
Data Analysis and Reporting Software
provides real-time viewing of event recordings
Four
dc or contact closure
<150kΩ
Event triggered
Event recording
15 minutes to 8 weeks,
50,000 events (512KB)
100 hours to >45 days
5.06 x 2.75 x 1.28"
(129 x 70 x 32mm)
6.4 oz (18g)
UL94-V0
IEC 68-2-27 (30G)
IEC 68-2-32 (1m)
▼
®
featureS
• Four input channels
• Works with dry contact closure or
0 to 3 and 0 to 5V
• Stores up to 50,000 events in
non-volatile memory
• Programmable units and scaling
• Powered by standard
Alkaline batteries
• Lightweight, compact, fits anywhere
• 5 LED indicators quickly and clearly
display logger status
• Includes FREE DataView
software for data storage, real-time
display, analysis and report generation
• Isolated USB 2.0 communication
cable
• EN 61010-1; 50V CAT III
dc logic levels
®
See page 58
for details
CATALOG NO. DESCRIPTION
2126.29 Simple Logger® II Model L404 (4-Channel, Event, DataView® software)
50
www.aemc.com
applicationS
• Determine machinery run/down times
• Determine event sequencing
• Count events and record
• Record event duration
• Accumulate rainfall data
Technical Assistance (800) 343-1391