AEMC L261, L481 Data sheet

Special
DATA LOGGERS
product
Simple Logger® II TRMS Voltage
DATA LOGGERS
Simple Logger® II TRMS Clamp-On Current
600Vac/dc Model L261 & ±850Vdc Model L481
One channel loggers for voltage measuring, monitoring and troubleshooting
SPECIFICATIONS
MODELS L261 L481
ELECTRICAL
Channels
Input Connection
Measurement Range
Resolution
Accuracy (50/60Hz)
Input Impedance
Sample Rate
Storage Rate
Storage Modes
Recording Length
Memory
Communication
Power Source
Battery Life
MECHANICAL
Dimensions
Weight (with battery)
Case
Vibration
Shock
Drop
Start/Stop, FIFO, Extended Recording Mode (XRM
Two recessed 4mm safety banana jacks
0 to 600V
0 to 5V: unspecified
5 to 50V:
± (0.5% of Reading + 1V)
50 to 600V:
± (0.5% of Reading + 0.5V)
64 samples/cycle Maximum of 8 per second
Programmable from 8 every second to 1 every day
15 minutes to 8 weeks, programmable using DataView
240,000 measurements (512KB)
The recorded data is stored in non-volatile memory and
will be retained even if the battery is low or removed.
2 x 1.5V AA-cell Alkaline batteries (included)
(dependent on sample rate and recording length)
4.94 x 2.75 x 1.28" (125 x 70 x 32mm)
IEC 68-2-6 (1.5mm, 10 to 55Hz)
PRODUCT INCLUDES
Set of two color-coded 5 ft voltage leads, color-coded alligator clips (red/black), USB type A to 5 pin Mini-B, and USB stick supplied with DataView® software and user manual.
ac/dc -850 to ±850Vdc
USB 2.0 optically isolated
One
0.1V
0 to 5V: unspecified
± (0.5% of Reading + 1V)
± (0.5% of Reading + 0.5V)
40M
100 hours to >45 days
6.4 oz (181g)
UL94-V0
IEC 68-2-27 (30G)
IEC 68-2-32 (1m)
5 to 50V:
50 to 850V:
) and Alarm
®
Model L261 only
IP 40
Rated
FEATURES
TRMS voltage recording up to 600Vac/dc (Model L261)
Bipolar voltage recording up to ±850V
dc (Model L481)
AC: 64 samples per cycle and
DC: 8 samples per sec (Model L261)
Programmable storage rates from 8 every
second to 1 every day
4 user selectable storage modes
Stores up to 240,000 measurements in
non-volatile memory
Powered by standard Alkaline batteries
Lightweight, compact, fits anywhere
5 LED indicators quickly and clearly
display logger status
Includes FREE DataView
®
software for data storage,
real-time display, analysis and report generation
Optically isolated USB 2.0 communication
cable included
EN 61010-1; 300V CAT IV; 600V CAT III
APPLICATIONS (MODEL L261)
Surge and Sag recording
Long term supply monitoring
Industrial, commercial and residential monitoring
Monitor voltage harmonics
Find intermittent voltage problems
Machine monitoring
APPLICATIONS (MODEL L481)
Rail voltage monitoring
Long term supply monitoring
Find intermittent voltage problems
Machine monitoring
Windmill monitoring
CATALOG NO. DESCRIPTION
2126.05 Simple Logger® II Model L261 (1-Channel, TRMS, 600Vac/dc, DataView® software)
2126.25 Simple Logger
www.aemc.com
®
II Model L481 (1-Channel, ±850Vdc, DataView® software)
Technical Assistance (800) 343-1391
Data Analysis and Reporting Software
Typical DataView® Functional Displays
Configure all data logger functions
Display and analyze real-time data on your PC
Configure all data logger functions and
Create and store a complete library of configurations that can
Zoom in and out and pan through sections of the graph to
Download, display and analyze recorded data
Display waveforms, trend graphs, harmonics (AC models)
Quick and simple configuration of all functions and settings from one dialog box.
Create custom views and reports
Print reports using standard or custom templates you design
Free software upgrades are available on
DATAVIEW®
DATAVIEW®
Software for Data Loggers
Software for Data Loggers
parameters from your PC including sample rate, recording length, channel configuration and more
be uploaded to the logger as needed
analyze the data
and text summaries
our website www.aemc.com
Configure scale functions.
Configure all alarm functions with straightforward selections.
Technical Assistance (800) 343-1391
Real-time display of all active inputs on computer through
®
DataView
software.
www.aemc.com
Loading...