AEMC L101 Data sheet

POWER QUALITY ANALYZERS, METERS & LOGGERS
GROUND RESISTANCE TESTER
Three-Phase Power Quality Analyzer
Simple Logger® II TRMS Current
Simple Logger® II TRMS Current
DATA LOGGERS
DATA LOGGERS
Multi-Function
Models L101 & L102
One channel loggers with the ability to perform a
variety of recording tasks
FEATURES
Compatible standard current probes with voltage
output and BNC connection (Models L101 & L102)
2 inputs (Model L102)
64 samples per cycle
Programmable storage rates from 8 every
second to 1 every day
4 user selectable storage modes
Stores up to 240,000 measurements in
non-volatile memory
Powered by standard Alkaline batteries
Lightweight, compact, fits anywhere
5 LED indicators quickly and clearly
display logger status
Includes FREE DataView
®
software for data storage,
real-time display, analysis and report generation
Optically isolated USB 2.0 communication cable included
EN 61010-1; 50V CAT III
APPLICATIONS (MODEL L101)
Load profiling
Fault current detection
Intermittent problem detection
Demand recording
Neutral current monitoring
Harmonic current recording using
DataView
®
software
Metering CT resizing
Start-Stop time stamping
APPLICATIONS (MODEL L102)
Split phase load monitoring
Neutral & ground current monitoring
Intermittent problem detection
Harmonic current monitoring using
DataView
Machine load monitoring
Start-Stop time stamping
®
software
SPECIFICATIONS
MODELS L101 L102
ELECTRICAL
Channels Input Connection Measurement Range Resolution Accuracy
(50/60Hz)
Input Impedance Sample Rate Storage Rate Storage Modes Recording Length Memory
Communication Power Source Battery Life
MECHANICAL Dimensions
Max Conductor Size Weight (with battery) Case Vibration Shock Drop
Start/Stop, FIFO, Extended Recording Mode (XRM
The recorded data is stored in non-volatile memory and will be
One Two BNC One BNC connector per channel
0 to 1V
0 to 10mV: unspecified
10 to 50mV: ±(0.5% of Reading + 1mV)
50 to 1000mV: ±(0.5% of Reading + 0.5mV)
64 samples/cycle
Programmable from 8 every second to 1 every day
15 minutes to 8 weeks, programmable using DataView
240,000 measurements (512KB)
retained even if the battery is low or removed.
USB 2.0 optically isolated
2 x 1.5V AA-cell Alkaline batteries (included)
100 hours to >45 days
(dependent on sample rate and recording length)
5.38 x 2.75 x 1.28" (136 x 70 x 32mm)
Current probe dependent
6.4 oz (181g) 6.64 oz (188g)
IEC 68-2-6 (1.5mm, 10 to 55Hz)
IEC 68-2-27 (30G)
IEC 68-2-32 (1m)
IP
40
Rated
ac (probe dependent)
0.1mV
800k
UL94-V0
) and Alarm
5.18 x 2.75 x 1.28" (132 x 70 x 32mm)
®
Special product
CATALOG NO. DESCRIPTION
2126.02 Simple Logger® II Model L101 (1-Channel, TRMS, 0 to 1Vac, DataView® software)
2126.03 Simple Logger
Technical Assistance (800) 343-1391
®
II Model L102 (2-Channel, TRMS, 0 to 1Vac, DataView® software)
www.aemc.com
DATA LOGGERS
Probe Selection Chart
AEMC
MODEL
NUMBER
MN261
JM830A
JM861
MF 300-6-2-10
300-24-2-1
1000-24-1-1
1000-24-2-1
1000-36-2-1
3000-24-2-0.3
6000-36-2-0.1
30000-24-2-0.1
AEMC CATALOG NUMBER
2115.82
2110.83 0.333mA/Aac 1 to 2400A 2400a
2110.90
2126.81
2112.88
2112.39 1mV/Aac 5 to 1000A 1000A
2112.98
2113.00
2114.87
2113.21
2113.33
PROBE
OUTPUT
100mV/A
10mV/Aac
10mV/Aac
1mV/Aac
0.1mV/Aac
100mV/A
10mV/Aac
100mV/A
10mV/Aac
ac
10mV
1mV/Aac
ac
10mV
1mV/Aac
3.3mV/A
0.3mV/Aac
1mV/A
0.1mV/Aac
1mV/A
0.1mV/Aac
ac
ac
ac
ac
ac
ac
PROBE RANGE
0.1 to 24Aac
0.5 to 240Aac
1 to 30Aac
1 to 300Aac
1 to 3000Aac
30Aac
300Aac
5 to 30A
5 to 300A
5 to 100A
5 to 1000A
5 to 100A
5 to 1000A
5 to 300A
5 to 3000A
5 to 600A
5 to 6000A
5 to 3000A
5 to 30,000A
MAX RANGE
FOR SLII
10Aac
100Aac
30Aac
300Aac
3000Aac
10Aac
100Aac
10A
100A
100A
1000A
100A
1000A
300A
3000A
600A
6000A
1000A
10000A
CABLE
DIAMETER
0.78"
(19.8mm)
2.52"
(64mm)
2.52"
(64mm)
1.77"
(44.96mm)
8"
(203.2mm)
8"
(203.2mm)
8"
(203.2mm)
11"
(279.4mm)
8"
(203.2mm)
11"
(279.4mm)
8"
(203.2mm)
BUS BAR
SIZE
N/A Lead w/BNC
1.97 x 5.31"
(50 x 134.87mm)
1.97 x 5.31"
(50 x 134.87mm)
2.25 x 0.75"
(57.15 x 19.05mm)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
OUTPUT
CONNECTION
Lead L111
Lead w/BNC
Sensor w/BNC
Sensor
w/Banana Plugs
Sensor
w/Banana Plugs
Sensor
w/Banana Plugs
Sensor
w/Banana Plugs
Sensor
w/Banana Plugs
Sensor
w/Banana Plugs
Sensor
w/Banana Plugs
USED WITH
LOGGER
MODEL
L101 L102 L562
L101 L102 L562
L101 L102 L562
L101 L102 L562
L101 L102 L562
L101 L102 L562
L101 L102 L562
L101 L102 L562
L101 L102 L562
L101 L102 L562
NOTES
Must use adapter
# 2118.46
Must use adapter
# 2118.46
Must use adapter
# 2118.46
Must use adapter
# 2118.46
Must use adapter
# 2118.46
Must use adapter
# 2118.46
Must use adapter
# 2118.46
MN01
MN02
MN03
MN93-BK
MN193-BK
MN251
MN255
www.aemc.com
2129.17 1mA/Aac 2 to 150A 150A
50mA to 100A
2129.20 1mA/Aac
2129.18 1mV/Aac 2 to 100Aac 100Aac
2140.32 5mV/Aac 2 to 240Aac 200Aac
ac
2140.36
2115.77 1mV/Aac 0.5 to 240A 240Aac
2115.81
200mV/A
10mV/Aac
100mV/A
10mV/Aac
ac
(1Ω)
50mA to 90A
(10Ω)
5 to 100Aac
0.1 to 24Aac
0.1 to 240Aac
100A
5A
100A
10Aac
100Aac
0.39"
(9.9mm)
ac
0.39"
(9.9mm)
0.47"
(11.94mm)
0.8"
(20.32mm)
0.8"
(20.32mm)
0.78"
(19.81mm)
0.78"
(19.81mm)
N/A Lead L111
N/A Lead L111
N/A
N/A Proprietary
N/A Proprietary
N/A
N/A
Lead
w/Banana Plug
Lead
w/Banana Plug
Lead
w/Banana Plug
L101 L102 L562
L104 L564
L104 L564
L101 L102 L562
L101 L102 L562
Must use adapter
# 2118.46
Must use adapter
# 2118.46
Must use adapter
# 2118.46
Technical Assistance (800) 343-1391