AEMC JM850A Data sheet

AC Current Probes Model JM850A (pdf) Rev. 03 10/05
Technical Assistance (800) 343-1391 www.aemc.com1of 4
AC Current Probe Model JM850A
The Model JM850A is high performance AC current probe for higher currents. Excellent transforma­tion and low phase shift, plus a broad frequency response, permit accurate measurements of current and power. The high quality magnetic cores and uniform windings provide for accurate measurements up to 1000A
AC/2000AAC/
3400A
AC. The “squared” jaw permits
multiple conductor or bus bar positioning. The Model JM850A provides excellent True RMS capabilities and reliable signal reproduction.
The Model JM850A works as a tradi­tional current transformer providing current outputs (mA) over a broad range of transformation ratios. The Model JM850A is designed for use on DMMs, power and harmonic meters, recorders or instruments with AC current ranges.

Features

Nominal range: 1000A, 2000A,
3000A (continuous cycle for the full temperature range)
• Transformation ratio: 1000:1 2000:1, 3000:1
Output: 1mA/
AC/AAC, 0.5mA/AC/AAC,
0.333mA/
AC/AAC
Designed for use on DMMs, power and harmonic meters, recorders or
instruments with AC current ranges

Applications

Field testing
Electrical utility
HVAC
Industrial maintenance
Laboratory
Plant maintenance
AC Current Probes Model JM850A (pdf) Rev. 03 10/05
Technical Assistance (800) 343-1391 www.aemc.com2of 4
MODELS JM850A
ELECTRICAL
Nominal Range 1000A, 2000A, 3000A Measurement Range 1 to 3400A Transformation Ratio 1000:1, 2000:1, 3000:1 Output Signal 1mA
AC/AAC (1A @ 1000A)
0.5mA
AC
/AAC (1A @ 2000A)
0.333mAAC/AAC (1A @ 3000A)
Accuracy (1000A Range)
50A 3% of Reading
200A 1.5% of Reading
1000A 1% of Reading
Phase Shift (1000A Range)
50A
200A 1.5°
1000A
Accuracy (2000A Range)
100A 1.5% of Reading 400A 0.75% of Reading
2000A 0.5% of Reading
Phase Shift (2000A Range)
100A 1.5° 400A 0.75°
2000A 0.5°
Accuracy (3000A Range)
150A 1.5% of Reading 600A 0.75% of Reading
3000A 0.5% of Reading
Phase Shift (2000A Range)
150A 1.5° 600A 0.75°
3000A 0.5°
Overload 1400A for 10 min (1000A)
2400A for 10 min (2000A) 3400A for 10 min (3000A)
Frequency Range 30 to 1000Hz, current derating above 1000Hz for continuous use Load Impedance 2.5Ω (1000A);
5Ω (2000A;
10Ω (3000A)
Working/Common Mode Voltage
600V
AC
Output Termination Jack
MECHANICAL
Operating Temperature 14° to 122°F (-10° to 50°C) Storage Temperature -13° to 176°F (-25° to 80°C) Jaw Opening 3.54" (90mm) Maximum Conductor Size Cable: 2.52" Ø max (64mm); Bus bar: 1.97 x 5.31" (50 x 135mm); 2.52 x 3.94" (64 x 100mm) Dimensions 4.72 x 12.40 x 1.89" (120 x 315 x 48mm) Weight 2.65 lbs (1200g) Polycarbonate Material Handles: 10% fiberglass charged polycarbonate UL94 VO; Jaws: ABS UL V2
SAFETY
Electrical EN61010-2-32 Electromagnetic EN 50081-1 Class B; EN 50082-2 Electrostatic discharge IEC 1000-4-2;
Compatibility Radiated field IEC 1000-4-3; Fast transients IEC 1000-4-4; Magnetic field at 50/60Hz IEC 1000-4-4
Double Insulation Yes
CE Mark Yes
Note: Reference conditions:
23°C ± 3°K, 20 to 85% RH, 45 to 65Hz, external magnetic field <40A/m, no DC component, no external current carrying conductor, test sample centered.

Specifications