AEMC J93-BK Specifications

CURRENT MEASUREMENT PROBES
AC/DC Current Probe Models J93 and J193
SPECIFICATIONS
MODELS Model J93 and J193 REFERENCE CONDITIONS
Model J193
►
DESCRIPTION
The Hall Effect Current Probe Models J93 and J193 are designed to measure DC currents up to 5000A and AC currents up to 3500A, without opening the circuit.
The Model J93 is powered by a 9V battery. The Model J193 is powered by the device (PEL Series only) to which it is connected.
►
APPLICATIONS
●Wind power monitoring
Rail signal monitoring
Third rail monitoring
General DC current monitoring
Temperature Relative Humidity DC Signal AC Signal Supply Voltage External Electric Field External DC Magnetic Field
(Earth’s Shield) External AC Magnetic Field Position of the Conductor ELECTRICAL Measurement Range Sensitivity Output Impedance Frequency Primary Current AC/DC
Amplitude Accuracy Phase Accuracy
RANGE OF USE RANGE OF INFLUENCE ACCURACY Temperature Relative Humidity Frequency Response Phase Shift Position of the Conductor in the Sensor Conductor Adjacent Voltage: Battery Meter Supply
Remanence Earth’s Magnetic Field POWER SUPPLY J93 J193 Power
Voltage MECHANICAL Dimensions Jaw Opening / Lead Length Weight Protection Index Drop SAFETY Rating Pollution Degree
1
Test performed with a 40x30 mm² cable and a current of 3500A at 50Hz. The accuracy % is the ratio of the
maximum variation to the mean value.
2
Test performed with a current of 300A at 50Hz.
± 2% ± 2.5A ± 1.5% ± 2.5A ± 1% ± 1% ± 1%
With an AC signal of which the distortion factor is <0.1%
45 to 65Hz with a DC signal <0.1%
J93: 9V ± 0.1V, J193: 5V ± 0.1V
50A to 3500Aac, 50A to 5000Adc
50 to
100Aac/Adc
1.5°
100 to
500Aac/Adc
14° to 131°F (-10° to 55°C) < 0.7% / 18°F (10°C)
10 to 90% RH < 0.7%
DC at 2kHz Curve A -Page 2 DC at 2kHz Curve B -Page 2
Any position
Conductor touching the jaws
J93: from 6.5 to 10V,
J193: 4.75 to 5.25V
At 5000Adc < 2A
9V Alkaline battery;
70hrs at 11mA
IEC 61010-2-032 and 61326-1; 600V CAT III , 300V CAT IV
23°C ±5°C
20 to 75% RH
Zero
< 40A/m
Zero
Centered in the probe jaws
1V / 3500A
100k
DC to 3kHz (-3 dB typical)
500 to
2000Aac/Adc
1
2
6.5 to 10V 5V ±0.25V
13.23 x 5.00 x 1.65" (336 x 127 x 42mm)
2.84" (72mm) / 10ft (3m) long
3.75 lbs (1.7kg) approx.
IP20 per standard IEC 60529
IEC 60068-2-32 (1m)
2000 to
3500Aac/Adc
< ± 2%
Rejection > 35 dB
± 2.25A typical
< 0.5A
Powered by the device it is
connected to (PEL Series)
at 5.4mA
2
3500 to
5000Adc
www.aemc.com
Technical Assistance (800) 343-1391
CURRENT MEASUREMENT PROBES
CURRENT MEASUREMENT PROBES
►
SPECIFICATIONCHARTS
Curve A: Typical Amplitude Error vs Frequency
Error (%)
5
0
-5
-10
-15
-20
-25
-30
-35
1 10 100 1000 10000
►
PRODUCTFEATURES
1. Jaw Ø 2.84" (72mm)
2. 4-point CA connector with 10 ft (3m) lead
3. Safety guard
4. Battery compartment cover (Model J93 only)
5. Zero adjustment knob
6. Power ON/Low battery indicator (Model J93 only)
7. Three-position switch: ON, OFF, battery test (Model J93 only)
Frequency (Hz)
1
2
Curve B: Typical Phase Error vs Frequency
Phase (°)
10
5
0
-5
-10
1 10 100 1000 10000
2.84"
(72mm)
Panel on inside of handle.
Frequency (Hz)
CATALOGNO. DESCRIPTION
2140.49
2137.78
www.aemc.com
AC/DC Current Probe Model J93-BK (3500Aac/5000Adc) for use with Models 8333, 8336, 8435 & PEL Series. Includes a soft carrying case, 9V battery, Velcro fastener, set of 12 color-coded ID markers and user manual.
AC/DC Current Probe Model J193-BK (3500Aac/5000Adc) for use with PEL Series only. Includes a soft carrying case, Velcro fastener, set of 12 color-coded ID markers and user manual.
©Copyright 2014, Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments
3
5
ZER O
ZERO
5000 A
500 A
ON
MARCH E
OFF
Stop
Test
SORTI E
300 V CAT IV 600 V CAT III
6
7
4
Technical Assistance (800) 343-1391