CURRENT MEASUREMENT PROBES
AC/DC Current Probe Models J93 and J193
SPECIFICATIONS
MODELS Model J93 and J193
REFERENCE CONDITIONS
Model J193
►
DESCRIPTION
The Hall Effect Current Probe
Models J93 and J193 are designed
to measure DC currents up to 5000A
and AC currents up to 3500A, without
opening the circuit.
The Model J93 is powered by a 9V
battery. The Model J193 is powered
by the device (PEL Series only) to
which it is connected.
►
APPLICATIONS
●Wind power monitoring
● Rail signal monitoring
● Third rail monitoring
● General DC current monitoring
Temperature
Relative Humidity
DC Signal
AC Signal
Supply Voltage
External Electric Field
External DC Magnetic Field
(Earth’s Shield)
External AC Magnetic Field
Position of the Conductor
ELECTRICAL
Measurement Range
Sensitivity
Output Impedance
Frequency
Primary Current AC/DC
Amplitude Accuracy
Phase Accuracy
RANGE OF USE RANGE OF INFLUENCE ACCURACY
Temperature
Relative Humidity
Frequency Response
Phase Shift
Position of the Conductor in the Sensor
Conductor Adjacent
Voltage: Battery Meter Supply
Remanence
Earth’s Magnetic Field
POWER SUPPLY J93 J193
Power
Voltage
MECHANICAL
Dimensions
Jaw Opening / Lead Length
Weight
Protection Index
Drop
SAFETY
Rating
Pollution Degree
1
Test performed with a 40x30 mm² cable and a current of 3500A at 50Hz. The accuracy % is the ratio of the
maximum variation to the mean value.
2
Test performed with a current of 300A at 50Hz.
± 2% ± 2.5A ± 1.5% ± 2.5A ± 1% ± 1% ± 1%
With an AC signal of which the distortion factor is <0.1%
45 to 65Hz with a DC signal <0.1%
J93: 9V ± 0.1V, J193: 5V ± 0.1V
50A to 3500Aac, 50A to 5000Adc
50 to
100Aac/Adc
4° 2° 1° 1.5° –
100 to
500Aac/Adc
14° to 131°F (-10° to 55°C) < 0.7% / 18°F (10°C)
10 to 90% RH < 0.7%
DC at 2kHz Curve A -Page 2
DC at 2kHz Curve B -Page 2
Any position
Conductor touching the jaws
J93: from 6.5 to 10V,
J193: 4.75 to 5.25V
At 5000Adc < 2A
9V Alkaline battery;
70hrs at 11mA
IEC 61010-2-032 and 61326-1; 600V CAT III , 300V CAT IV
23°C ±5°C
20 to 75% RH
Zero
< 40A/m
Zero
Centered in the probe jaws
1V / 3500A
≥ 100kΩ
DC to 3kHz (-3 dB typical)
500 to
2000Aac/Adc
1
2
–
6.5 to 10V 5V ±0.25V
13.23 x 5.00 x 1.65" (336 x 127 x 42mm)
2.84" (72mm) / 10ft (3m) long
3.75 lbs (1.7kg) approx.
IP20 per standard IEC 60529
IEC 60068-2-32 (1m)
2000 to
3500Aac/Adc
< ± 2%
Rejection > 35 dB
± 2.25A typical
< 0.5A
Powered by the device it is
connected to (PEL Series)
at 5.4mA
2
3500 to
5000Adc
www.aemc.com
Technical Assistance (800) 343-1391
CURRENT MEASUREMENT PROBES
CURRENT MEASUREMENT PROBES
►
SPECIFICATIONCHARTS
Curve A: Typical Amplitude Error vs Frequency
Error (%)
5
0
-5
-10
-15
-20
-25
-30
-35
1 10 100 1000 10000
►
PRODUCTFEATURES
1. Jaw Ø 2.84" (72mm)
2. 4-point CA connector with
10 ft (3m) lead
3. Safety guard
4. Battery compartment cover
(Model J93 only)
5. Zero adjustment knob
6. Power ON/Low battery indicator
(Model J93 only)
7. Three-position switch: ON, OFF,
battery test (Model J93 only)
Frequency (Hz)
1
2
Curve B: Typical Phase Error vs Frequency
Phase (°)
10
5
0
-5
-10
1 10 100 1000 10000
2.84"
(72mm)
Panel on inside of handle.
Frequency (Hz)
CATALOGNO. DESCRIPTION
2140.49
2137.78
www.aemc.com
AC/DC Current Probe Model J93-BK (3500Aac/5000Adc) for use with Models 8333, 8336, 8435 & PEL Series.
Includes a soft carrying case, 9V battery, Velcro fastener, set of 12 color-coded ID markers and user manual.
AC/DC Current Probe Model J193-BK (3500Aac/5000Adc) for use with PEL Series only.
Includes a soft carrying case, Velcro fastener, set of 12 color-coded ID markers and user manual.
©Copyright 2014, Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments
3
5
ZER O
ZERO
5000 A
500 A
ON
MARCH E
OFF
Stop
Test
SORTI E
300 V CAT IV
600 V CAT III
6
7
4
Technical Assistance (800) 343-1391