MODELS DL-1080 & DL-1081
ELECTRICAL
Input Type Measuring Range: Accuracy:
Linear 0 to 20mA Linear 4 to 20mA Linear 0 to 20mV Linear 0 to 50mV Linear 0 to 60mV
Linear -20 to 20mV
Linear 0 to 5V
Linear 0 to 10V
Digital Inputs
Internal Memory Excitation Current
Maximum Pt100/Pt1000 Compensated Cable Resistance
Maximum Input Voltage Input Current @ 30Vdc
(typical)
Digital Outputs
Storage Rate
Maximum Channel Logged Supported Modbus
Commands
Power Supply
ENVIRONMENTAL
Operating Temperature Relative Humidity
Altitude
Protection
F.R. = Full Range *The full scale refers to the input of the sensor signal and not the range of configured indication.
J
-184º to 1832ºF (-120 to 1000ºC)
K
-202º to 2501.6ºF (-130 to 1372ºC)
T
-202º to 752ºF (-130 to 400ºC)
E
-202º to 1436ºF (-130 a 780ºC)
N
-202º to 2372ºF (-130 to 1300ºC)
R
68º to 3214.4ºF (20 to 1768ºC)
S
68º to 3214.4ºF (20 to 1768ºC)
B
Pt100
Pt1000
212º to 3308°F (100 to 1820ºC)
-328º to 1562ºF (-200 to 850ºC)
-328º to 1562ºF (-200 to 850ºC)
User Programmable ± 0.15% (F.R.)*
Maximum relay current: 3A @ 250Vac; 3A @ 30Vdc
100 to 240V
For temperatures higher than 85°F (30°C),
Logic level “0”: from 0 to 0.8V
Logic level “1”: from 3 to 30Vdc
2MB
Pt100s: 360µA; ; Pt1000s: 320µA
40
30Vdc
3mA
Maximum output voltage: 30V
Maximum output current: 200mA
from 1ms to 24 hours
100
Read Coil Status (01h)
Read Holding Registers (03h)
Write Single Coil (05h)
Write Single Register (06h)
Write Multiple Registers (0Fh)
ac, 50/60Hz. 20VA (max)
32° to 122°F (0 to 50°C)
80% up to 85°F (30°C)
decrease 3% per °C
< 6500 ft (2000m)
IP20
± 0.2% (F.R.) ± 1ºC
± 0.2% (F.R.) ± 3ºC
± 0.15% (F.R.)
dc
dc
Inputs rated CAT II
IP 20
Rated
FEATURES
8 universal analog input channels
8 digital I/Os (individually configured as
inputs or outputs)
2 relay outputs (NO, NC and common)
RS485 interface
24Vdc output to power up to eight
4 to 20mA transmitters
Ethernet interface for LAN and
internet use
USB-device interface for configuring,
monitoring and download
USB-host interface for logged data
retrieval through a USB flash drive
Up to 32 configurable alarms
Up to 128 virtual channels
Detachable display (optional)
Up to 100 channels can be logged at a
configurable rate
Data downloading through the
configuration software or through the freely distributed download DLL
4 input channel types: analog, digital,
remoted and virtual
16GB SD card interface
www.aemc.com
Technical Assistance (800) 343-1391
Model DL-1081
Color Functional Displays
"FAVORITES" Screen
Shows a six-position grid where you can assign a channel to be displayed real-time in each position.
"CONFIGURATION" Screen
Data logger and display parameters can be changed and viewed on this screen.
"CHART" Screen Software Screens
Displays a plot of the favorite channels values.
"ALARMS" Screen
A 32-position grid where each numbered position is related to its equivalent alarm or event. When an alarm is active, its number will be displayed in red on this screen.
CATALOG NO. DESCRIPTION
2134.61 Data Logger Model DL-1080 (8 Analog to 8 Digital Channel, no LCD)
2134.62 Data Logger Model DL-1081 (8 Analog to 8 Digital Channel, LCD)
Technical Assistance (800) 343-1391
PRODUCT INCLUDES
DL-1080 & DL-1081 software
USB stick supplied with software,
drivers and user manual
www.aemc.com