AEMC CL601 Data sheet

Special
product
features
E
G
R
G
&
O
L
C
L
A
M
E
P
M
DATA LOGGERS
Simple Logger® II TRMS Clamp-On Current
Simple Logger
R
Model CL601
E
T
®
II TRMS Clamp-On Current
S
D
U
R
O
C
E
R
6
0
0
A
U
T
B
T
E
N
'
'
'
'
O
O
P
E
R
T
A
Designed for plant and field service
P
T
O
applications and for use in harsh
C
A
environments
O
N
N
O
I
SPECIFICATIONS
MODEL CL601
ELECTRICAL
Channels
Input
Measurement Range
Resolution
Accuracy (50/60Hz)
Sample Rate
Storage Rate
Storage Modes
Recording Length
Memory
Communication
Power Source
Battery Life
MECHANICAL
Dimensions
Max Conductor Size
Weight (with battery)
Case
Vibration
Shock
Drop
5 to 50A: ±(1% of Reading + 1A)
50 to 400A: ±(1% of Reading + 0.5A)
400 to 600A: ±(3% of Reading + 1A)
Programmable from 8 every second to 1 every day
Start/Stop, FIFO, Extended Recording Mode (XRM™)* and Alarm
15 minutes to 8 weeks, programmable using DataView
240,000 measurements (512KB) - The recorded data is
stored in non-volatile memory and will be retained even if the
battery is low or removed.
USB 2.0 optically isolated
2 x 1.5V AA-cell Alkaline batteries (included)
(dependent on sample rate and recording length)
9.25 x 4.0 x 1.63" (235 x 102 x 41mm)
1 conductor - Ø 1.42" (36mm)
2 conductor - Ø 1.00" (25mm) ea
IEC 68-2-6 (1.5mm, 10 to 55Hz)
One
Split CT – AC Current
0 to 600Aac
0.1A
0 to 5A: unspecified
64 samples/cycle
100 hours to >45 days
17.1 oz (485g)
UL94-V0
IEC 68-2-27 (30G)
IEC 68-2-32 (1m)
IP 40
Rated
®
FEATURES
0 to 600Arms
True RMS measurements
Self contained, no exposed connections
Overload indication
Optically isolated USB 2.0 communication
cable included
One button operation
Alarm function
5 LED indicators quickly and clearly
display logger status
Powered by standard Alkaline batteries
Includes FREE DataView® software for
data storage, real-time display, analysis and report generation
EN 61010-1; 300V CAT IV, 600V CAT III
www.aemc.com
APPLICATIONS
*Extended Recording Mode (XRM™)
This unique recording mode provides the opportunity to continuously record over long periods of time by reducing the stored samples of the oldest data and maintaining matching resolution for the newest data. Each time the memory fills up using XRM™ every other of the oldest stored samples is discarded making room for newer samples. This process continues until the recording is manually stopped.
CATALOG NO. DESCRIPTION
2126.01 Simple Logger® II Model CL601 (1-Channel, TRMS, Clamp-On, 0 to 600Aac, DataView® software)
Machine load monitoring
HVAC troubleshooting
Load profiling
Electrical troubleshooting
Start-Stop time stamping
Technical Assistance (800) 343-1391
Technical Assistance (800) 343-1391
Data Analysis and Reporting Software
Typical DataView® Functional Displays
Configure all data logger functions
Display and analyze real-time data on your PC
Configure all data logger functions and
Create and store a complete library of configurations that can
Zoom in and out and pan through sections of the graph to
Download, display and analyze recorded data
Display waveforms, trend graphs, harmonics (AC models)
Quick and simple configuration of all functions and settings from one dialog box.
Create custom views and reports
Print reports using standard or custom templates you design
Free software upgrades are available on
DATAVIEW®
DATAVIEW®
Software for Data Loggers
Software for Data Loggers
parameters from your PC including sample rate, recording length, channel configuration and more
be uploaded to the logger as needed
analyze the data
and text summaries
our website www.aemc.com
Configure scale functions.
Configure all alarm functions with straightforward selections.
Technical Assistance (800) 343-1391
Real-time display of all active inputs on computer through
®
DataView
software.
www.aemc.com
Loading...