![](/html/99/99d7/99d7227d4f3dc1a954f2575d9d8e52646defb439e3a3c1368c890d092e22b4ad/bg1.png)
FEATURES
• Easy one-hand operation
• Dual K-type thermocouple included
• Measures temperature in °F and °C
• 0.1° resolution
• Max and hold functions
• 2000-count backlit LCD
• Lightweight and compact
• Includes rugged, shockproof,
protective and
dirt resistant gray holster
APPLICATIONS
• Process control monitoring and
troubleshooting
• HVAC installation and maintenance
• Chemical processing
• Food processing
• Mold injecting and HVAC for
temperature rise and fall
• Indoor/outdoor differential temperature
measurements
• Plastics
ENVIRONMENTAL TESTERS
Thermometer
Model CA863
Offers the ability to easily switch
between temperature readings on both
channels (T1 & T2) and differential (DT)
SPECIFICATIONS
MODEL CA863
MEASUREMENTS
Input
Temperature Scale
Measurement Range
Display Resolution
Sensor
Accuracy
(Instrument)
Input Protection
Sample Rate
Input Connector
GENERAL
Display
Operating Temperature
Storage Temperature
Polarity
Power Source
Low Battery Indication
Accepts two standard miniature K-type thermocouple plugs
3½ digit liquid crystal display (LCD), 2000-count
-4° to 140°F (-20° to 60°C), 0 to 80% RH without battery
is displayed when battery voltage is low
Dual K-type thermocouple
Fahrenheit or Celsius user selectable
-58° to 1999°F or -50° to 1300°C
1°F or 1°C, 0.1°F or 0.1°C
K-type thermocouple dual input (included)
-58° to 1999°F: ±0.3% of Rdg ± 2°F
-50° to 1000°C: ±0.3% of Rdg ± 1°C
1000° to 1300°C: ±0.5% of Rdg ± 1°C
24Vdc or 24Vrms
2.5 times per second
32° to 122°F (0° to 50°C), 80% RH
Automatic
One 9V Alkaline battery (included)
FEATURES
• Easy one-hand operation
• Non-contact infrared sensor
• Laser guide for precise aim
• Measures temperature in °F and °C
• High 1022°F/550°C measurement
• Adjustable emissivity 0.1 to 1.00
• Auto-Hold function
• 2000-count backlit LCD
• Lightweight and compact
• Removable protective laser cover
• Includes rugged, shockproof,
protective and dirt resistant gray
holster
APPLICATIONS
• Electrical troubleshooting
• Food safety and processing
• Automotive repair and maintenance
• Marine maintenance and repairs
• Test faulty motor winding insulation
• Test overheated high voltage transformers
• Test terminals on circuit breaker panels
• Perform HVAC energy audits
Features a laser guide for precise
infrared temperature measurement
SPECIFICATIONS
MODEL CA876
MEASUREMENTS — INFRARED
Temperature Range
Display Resolution
Accuracy
Response Time
Emissivity
Sensor
Optical Lens
Laser
MEASUREMENTS — K TYPE
Temperature Range
Display Resolution
Sensor
Accuracy
GENERAL
Display
Operating Temperature
Storage Temperature
Polarity
Power Source
Low Battery Indication
-4° to 140°F (-20° to 60°C), 0 to 80% RH without battery
-4° to 1022°F or -20° to 550°C
1°F or 1°C
±2% of Reading or ± 6°F (3°C)
One second
Adjustable 0.10 to 1.00
Thermopile
Fresnel Lens
<0.5mW (670nm)
-40° to 2000°F or -40° to 1350°C
1°F or 1°C or 0.1°F or 0.1°C (Auto)
K-type thermocouple (included)
-40° to 2000°F: ±0.1% of Reading ± 2°F
-40° to 1350°C: ±0.1% of Reading ± 1°C
3½ digit liquid crystal display (LCD), 2000-count
32° to 122°F (0° to 50°C), 80% RH
Automatic
One 9V Alkaline battery (included)
is displayed when battery voltage is low
Model CA876
CATALOG NO. DESCRIPTION
2121.27 Thermometer Model CA863 (Dual K-type Thermocouple)
2121.34
Infrared Thermometer Model CA876 (Laser, var
Technical Assistance (800) 343-1391
ε, K-type Thermocouple, -4° to 1022°F)
www.aemc.com