AEMC CA7024 Data sheet

DATA LOGGERS
FEATURES
500V and 1000V
Insulation measurements to 4000MΩ
Resistance measurements to 4000Ω
Continuity test
Continuity beeper
600VAC/DC test voltage range
Large, easy-to-read digital display
Data hold switch
Test button may be “locked-on” for
three minutes for hands-free operation
Automatic discharge when test button
is released
Low battery indicator
Includes test leads and soft carrying case
EN 61010-1, 1000V CAT II, 600V CAT III
CABLE TESTERS
Fault Mapper® Cable Length Meter & Fault Locator Alphanumeric TDR
Special product
features
CABLE TESTERS
Fault Mapper Cable Length Meter & Fault Locator Alphanumeric TDR
Simple Logger® II TRMS Current
Model CA7024
Special product
features
C
E
T
T
E
S
D
O
P
E
N
S
H
&
S
S
T
R
O
FEATURES
Finds opens, shorts and cable length
SPECIFICATIONS
MODEL CA7024
MEASUREMENTS
Range @ Vp = 70%
Resolution
Accuracy Minimum Cable
Length Cable Library Velocity of
Propagation (Vp) Output Pulse
Output Impedance
Display Resolution
Tone Generator
Voltage Warning
Power Source
Auto Power OFF
Weight
0.1 ft up to 100 ft, then 1 ft (0.1m up to 100m, then 1m)
5V (peak to peak) into open circuit; nanosecond rise Step Function
6000 ft or 2000m (selectable)
±2% of Reading
12 ft (4m)
Built-in, user selectable and user programmable
Adjustable from 0 to 99%
Automatic compensation
128 x 64 pixel graphical LCD
Oscillating 810 to 1110Hz
Triggers at >10V
Four 1.5V AA Alkaline batteries (included)
After three minutes
12 oz (350g)
AC/DC
U
S
R
A
E
E
S
M
C
H
A
T
B
G
L
N
E
E
L
N
I
T
-
O
T
L
N
I
E
U
B
G
R
E
O
N
T
E
A
R
Hand-held Cable Length Meter and Fault Locator
for multiple conductor cables
Detects opens and shorts and the distance to them from
one end of the cable
Measure cable length up to 6000 ft or 2000m (selectable)
Automatic cable impedance compensation
Built-in library of most common cables
and their Velocity of Propagation (Vp)
Manual selection of Vp for all cables not found in library
User programmable cable library with
15 storage positions
Vp setting displayed along with length and
cable type (if in library)
Built-in tone generator for tracing and locating cables
Large high-visibility blue electroluminescent backlit display
Tone Receiver/Cable Tracer Model TR03 (optional):
Compatible with Models CA7024, CA7027 and CA7028
One button operation
Volume control
Audio output
CATALOG NO. DESCRIPTION
Tone Receiver
Cable Tracer
Model TR03
available as an accessory
PRODUCT INCLUDES
Soft carrying case,
BNC pigtail cable with
alligator clips, four 1.5V AA
batteries and user manual.
2127.80 Fault Mapper Model CA7024 (Cable Fault / Length Tester – Alphanumeric TDR)
Accessories (Optional)
2127.76 Tone Receiver/Cable Tracer Model TR03
Technical Assistance (800) 343-1391
www.aemc.com
Special product
features
D
C
I
I
S
H
P
P
A
R
G
O
F
T
L
F
A
U
CABLE TESTERS
Fault Mapper Pro® Telephone Cable Tester / Graphical TDR
L
A
Y
Model CA7027
S
C
S
A
E
R
U
S
A
E
M
1
9
,
0
0
0
M
P
I
S
T
C
E
T
E
~
D
M
I
S
M
A
C
T
Maps and pinpoints the
B
L
E
T
locations of faults on power
O
t
f
and communication cables
E
D
A
N
C
E
S
E
H
Learn the importance
of a structured
cable tester
SPECIFICATIONS
MODEL CA7027
MEASUREMENTS
Range @ Vp = 70%
Range Selection Accuracy Resolution Minimum Cable Length Sensitivity
Velocity of Propagation (Vp)
Output Pulse Output Impedance Output Pulse Width Scan Rate Tone Generator Voltage Protection Power Supply Battery Life Auto Power OFF Weight (with battery)
23, 49, 98, 197, 394, 820, 1640, 3280,
6560, 9850, 19000 ft Manual range control
±1% of range
Approximately 1% of selected range
5 ft (1.5m)
Minimum 3 pixel return on a fault at
4km on 0.6mm 0, PE, TP
Adjustable from 1% to 99%
+5V peak to peak into an open circuit
Selectable between 25, 50, 75 & 100
3 ns to 3 ms, Automatic with range
2 scans / second or scan held
Oscillating tone 810 to 1110Hz
ac
250V
Four 1.5V AA Alkaline batteries
60 hours continuous scanning
Selectable 1, 2, 3, 5 minutes or disabled
12oz (350g)
FEATURES
11 range scales indicating cable faults and
terminations up to 19,000 ft (6000m) in feet or meters
Unique graphical and digital display of fault
information and length
Detects opens, shorts, taps, faulty taps,
bridge taps, splitters, high resistance, wet cables, splices and more
Identifies impedance mismatches
Works with twisted pair, parallel and
coaxial cable
Dead band less than 9 ft
Selectable cable impedance
(25, 50, 75, 100)
PRODUCT INCLUDES
Soft carrying case,
Over-voltage protection up to 250V
Adjustable cursor assists in locating faults
4mm color-coded banana plugs with alligator clips, four 1.5V AA batteries and user manual.
Built-in tone generator for tracing and
Large high-visibility blue electroluminescent
CATALOG NO. DESCRIPTION
2127.84 Fault Mapper Pro® Model CA7027 (Telephone Cable Tester / Graphical TDR)
Accessories (Optional)
2127.76 Tone Receiver/Cable Tracer Model TR03
4
www.aemc.com
and termination
locating cables
backlit display
Technical Assistance (800) 343-1391
Loading...