AEMC AEMC OX 9104 IV 100MHz Brochure

Page 1
Oscilloscope
OX 9000 SERIES
4-in-1 Instrument
Oscilloscope
Multimeter
Analyzer
99 Washington Street Melrose, MA 02176
Phone 781-665-1400 Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
isolated channels
with the recorded files directly viewable on screen
Safety
All channels isolated from one another and from the earth, 600V CAT III
Ergonomic
Modern, high tech design which is simple, compact and practical
Optimization
of all tools; communication, storage and operation
Our products are backed by over 125 years of experience in test and measurement equipment, and encompass the latest international standards for quality and safety.
Page 2
OSCILLOSCOPE OX 9000 SERIES
ERGONOMICS
Designed to simplify use with one button access to most functions
In a housing tailor-made to be as compact as possible, the mechanical design makes it possible to integrate the hardware components in a small size with the keypad benefits from new technology developed in the automotive industry.
CHANNEL AND PARAMETER IDENTIFICATION
Each channel and related parameters are identified with identical color against a black background for simpler, quicker viewing.
EASY ACCESS VIA TOUCH SCREEN
Intuitive icons are provided to facilitate their use, even with gloves on.
ADJUSTABLE STRAP
This helps to optimize operation of the oscilloscope in your hand or on your shoulder when working in the field.
A stand is also available to vary the orientation of the oscilloscope when it is placed on a bench. The oscilloscope can be safely left unattended using the Kensington locking system.
IP
54
ETHERNET
NEW KEYPAD DESIGN FOR OPTIMUM USER COMFORT
Configuration and measurement displays are simple to access from the front panel in one of these 5 specific areas: Utilities (brightness, full screen, screenshot), Measurements, Vertical, Horizontal, Trigger.
LINE POWER OR LI-ION BATTERY
Port on left side.
PRODUCT INCLUDES
Scope in carrying case with shoulder strap, set of two 5 ft color-coded leads, alligator clips and test probes, 10 ft USB cable, µSD memory card, 1-PROBIX Banana Plug Adapter, set of 5 styli pens, LI-ION 5.8 Ah battery pack, PA40W-2 power adapter with 110V power cord. Additional accessories may be model dependent.
Page 3
OSCILLOSCOPE OX 9000 SERIES
APPLICATIONS
Ideal for electronic and industrial maintenance
IP54
Housing protected against dust and water spray.
7" WVGA WIDE COLOR TFT TOUCH SCREEN
Makes it easy to view and read the measurements clearly. It also provides a screen resolution of 800 x 480 dpi with manual or automatic brightness.
TOUCH-SCREEN STYLUS STORAGE
Among the essential tools available, the sylus is equipped with a hook for the addition of a cord to make it captive, as required. One end is slightly flattened to prevent rolling when placed on a table or bench.
AUTOSET BUTTON
Quickly and effortlessly adjusts the horizontal and vertical; sensitivity and scales to provide the best resolution.
DIRECT SETTING AND SET-UP BUTTONS
COMMUNICATION INTERFACES
Electronic maintenance
The OX 9304 model is ideal for electronics with its 300 MHz bandwidth, 4 x 600V CAT III isolated channels, advanced trigger functions, integrated FFT function, complex mathematical calculations on the curves, automatic measurements on 4 channels and the built-in WEB server.
Industrial maintenance
The OX 9304’s large 7-inch screen, 300 MHz bandwidth, 4 x 600V CAT III isolated channels and Harmonic Analyzer and Multimeter modes make it ideal for industrial maintenance applications.
These are isolated from one another and from the measurement channels. A dedicated compartment on the right side protected by a flexible cover contains all the different communication interface ports:
USB host for communication with a PC
wired RJ45 or WiFi for communication with a PC or
printing via a network printer
µSD card for data storage with quick transfer and for
upgrading of the instrument's firmware
DIRECT ACCESS ZOOM BUTTON
Channels are isolated.
CATALOG NO. DESCRIPTION
2150.31 ....................................................................................................................................Hand-Held Oscilloscope Model OX 9062 IV 60MHz
2150.32 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9102 IV 100MHz
2150.33 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9104 IV 100MHz
2150.34 ..................................................................................................................................Hand-Held Oscilloscope Model OX 9304 IV 300MHz
Page 4
OSCILLOSCOPE OX 9000 SERIES
ACCESSORIES
Accessories automatically recognized when connected to the oscilloscope
The plug and play accessories included are automatically recognized when connected to the oscilloscope. They provide quick and easy implementation with total user safety. Additionally, accessories equipped with BNC connectors or standard banana plugs can also be connected when using the supplied adapter.
Interchangeable ID Markers can be used on the accessories plugged into a given channel to identify them with the trace color displayed on the screen.
Additionally the 10:1 probe accessory is equipped with 3 adjustable buttons to optimize its measurement capabilities.
Identication and Safety Management
Once one of the provided standard accessories has been plugged in, it is automatically identified and its characteristics and calibration references are retrieved by the OX9000 Series Oscilloscope. All accessories are directly powered by the oscilloscope.
Channel Conguration and Sensor Management
Sensor coefficients scales and units of measure are managed automatically, as is channel configuration. Control buttons on the probes can be used to modify the settings of the channels to which they are connected. They also offer functions accessible on the oscilloscope's front panel.
PROBE FUNCTIONS
voltage measurements
• by probe with different bandwidths and attenuation
• by BNC or banana jack connection
current measurements
• by AC or AC/DC current clamp
• directly through banana jack connections
temperature measurements
• using a K thermocouple sensor
• using a PT100 RTD sensor
Accessories & Replacements
Cat #2124.73 - PROBIX PRHX1 10:1 Probe, 250MHz 600V CAT III Cat #2124.77 - PROBIX Current Probe, 20mA-20A 1MHz-3dB Cat #5000.17 - Set of 5 styli pens
Page 5
OSCILLOSCOPE OX 9000 SERIES
COMMUNICATION
For added equipment and operator safety all communication from the
instrument is totally isolated from the measurement process
Choice of communication interfaces―you can choose the type of communicaton to fit your requirements. Several communication choices are built into the OX9000 Series oscilloscope.
• Wired Ethernet LAN network with integrated DHCP server for easy connection to your network
• WiFi® radio link to communicate with a PC, tablet or smartphone using the dedicated interfaces
• USB for interfacing with the PC; record, recall or load configurations
• µSD with >8 GB, default storage giving priority over the 1 GB internal memory
File Management
Any of the signal traces can be displayed instantaneously as the reference by pressing a single button which will obtain a comparison an immediate measurements of the deviation of ongoing measurements.
Backups are available in various formats for direct export into a standard application such as Windows base spreadsheets or word processors.
It is easy to take screenshots directly from the front panel and save them in a .PNG format, print documents on a network printer and transfer or delete files in the file manager.
Electrical Troubleshooting
Education
Storage capability
Type of le
for each mode
setup (cfg)
traces (trc)
math (fct)
Oscilloscope mode
Multimeter mode
Logger mode
Harmonics mode
          
Data Processing
• Use the oscilloscope screen to recall screenshots and stored traces for direct review on screen
• On your PC, use the ScopeNet application in your web browser with either the USB or Ethernet connection for remote control and programming with SCPI commands
meas (txt)
screen shot (png)
In the laboratory
Page 6
OSCILLOSCOPE OX 9000 SERIES
4 MODES: Oscilloscope, Multimeter, Analyzer, Recorder
Improved functions and performance levels of the OX9000 Series
• wider bandwidth up to 300 MHz
• new triggering and recording options
• increased storage capacity, and more!
OSCILLOSCOPE:
• 12 bit resolution
• 2.5 GS/sec
Trigger Functions
An oscilloscope with complex trigger functions records what is necessary, while capturing all the faults The OX9000 models offer advanced triggers which complement the main edge trigger options: pulse width, counting and delay.
• The Delay mode enables you to observe any event with maximum resolution, even if it occurs a long time after effective triggering, or on two different channels.
• The Counting mode enables you to count the events before triggering, so that you can check the content of digital frames. For example, the trigger can be linked to a second “auxiliary” signal which is different from the “main” signal.
Automatic Measurements
Comprehensive automatic measurements are displayed with cursors for precise analysis. The automatic measurements window displays all 20 parameters at the touch of a button for 4 channels. Two horizontal and vertical cursors can be used to view the section of the signal where the first automatic measurement was performed.
The Math Functions
In oscilloscope mode, the MATH functions (1, 2, 3 and 4) allow you to define a mathematical function for each of the traces, along with vertical scaling and labeling of the actual physical unit.
The mathematical editor is capable of displaying 4 calculated traces on which all the automatic or cursor measurements remain available. This means it is possible to examine the waveforms, such as the power (V x I), and perform all the associated measurements.
A large number of operators are available, including +,
-, x and / , as well as more complex operators such as sine, cosine, exponential, logarithm, square root, etc. opening the way for specific applications.
Real-time Fast Fourier Transform (FFT) for frequency decomposition of your signals on 4 channels
The FFT is used to calculate, from 2500 points upwards, the discrete representation of a signal in the frequency domain from its representation in the time domain. It is often particularly useful for arriving at an effective diagnosis during qualitative analysis of the signals:
A specific measurement area can then be selected by framing it with manual cursors for more accurate, reliable results.
Direct comparison of two traces can be performed by checking the “reference memory deviation” box, so that these 20 signal parameters are displayed in terms of deviations.
PRACTICAL!
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
VIEW ALL 4 CHANNELS SIMULTANEOUSLY
waveform + FFT waveform + XY waveform + zoom
TestEquipmentDepot.com
• measurement of the individual harmonics or distortion of a signal
• analysis of a pulse response
• search for the source of noise in the logic circuits
Several weighting windows are available, as well as 2 representation modes: linear or logarithmic (scale in dB). The 2 cursors can then be used for precise measurements of the frequency lines, the levels and the attenuations, taking advantage of the 80 dB dynamic range allowed by the 12-bit /
2.5 GS/s conversion.
The autoset button makes it easier to obtain an optimum spectral representation to which a graphical zoom can be applied to analyze all the details of the spectrum.
Page 7
OSCILLOSCOPE OX 9000 SERIES
4 MODES: Oscilloscope, Multimeter, Analyzer, Recorder
The four modes are directly accessed at the press of a button or touch
screen icon providing instant access the mode you need
Harmonic Analysis
Harmonic analysis is performed on all 4 channels up to the 63rd order to comply with the requirements of the EN 50160 standard (THD on harmonics up to the 50th), with a fundamental frequency between 40 and 450 Hz.
It is possible to preselect the frequency of the fundamental for the standards (50 Hz, 60 Hz and 400 Hz).
This function helps to improve analytical performance and, above all, measurement when the level of a harmonic order is greater than the fundamental.
It is possible to view the harmonic analyses of two or four channels simultaneously: RMS level, harmonic distortion, harmonic frequency, phase of the harmonic in relation to the fundamental.
Multimeter
By simply selecting the dedicated icons, you can gain access to the multimeter mode without changing the measurement input channels. The OX9000 models offer an 8,000-count TRMS digital multimeter with two or four channels which can perform the following measurements:
Harmonics
4 Simultaneous Channels
• amplitude (DC or AC voltage and current, power, temperature, etc.)
• resistance, continuity, capacitance
• component diode tests
Temperature is measured using the Pt 100 and Pt 1000 sensors or K thermocouples via the dedicated PROBIX sensors. The power measurements are proposed as follows with choice of the configuration:
• single-phase power
• three-phase power on balanced network without neutral
• three-phase power on balanced network with neutral
• 3-wire three-phase power (2-wattmeters method)
Measurement between H and V cursors: T1, T2, Dt, 1/Dt, V1, V2, dV, Ph
Recorder/logger
This is the mode for recording the trends in Multimeter mode. A genuine fast digital logger is provided inside the instrument to monitor the variations of physical or mechanical phenomena over time. It offers acquisition intervals as short as 40µs between 2 measurements and recording can cover any period from 2 seconds to one month.
Technical Assistance (800) 343-1391 www.aemc.com 7
Page 8
TECHNICAL SPECIFICATIONS
HUMAN-MACHINE INTERFACE
Type of display 7" WVGA color TFT LCD touch screen, 800x480 – LED backlighting (adjustable standby mode) Different display mode 2,500 real acquisition points on screen - Vectors with interpolation Display of curves on screen 4 curves + 4 references – Split Screen & Full Screen modes Screen commands Touch screen – ANDROID-type icons and graphical commands – customizable channel colors Choice of language 15 complete languages, menus & online help
OSCILLOSCOPE MODE
Vertical deection
Bandwidth
Number of channels 2 isolated channels 4 isolated channels
Input impedance 1 MΩ ± 0.5% , approx. 12 pF
Maximum input voltage 600 V / CAT III (1,000V per Probix) – from 50 to 400 Hz – Probix safety connectors
Vertical sensitivity 16 ranges from 2.5 mV to 200 V/div and up to 156 µV/div in vertical zoom mode (12-bit converter) – Accuracy ± 2%
Vertical zoom "One Click Winzoom" mode (12-bit converter and direct graphical zoom on screen) – x 16 max.
Probe factor (non-Probix) 1 / 10 / 100 / 1,000 or any scaling – denition of measurement unit
Horizontal deection
Sweep speed 35 ranges from 1 ns/div to 200 s/div., accuracy ± [50 ppm + 500 ps] – Roll mode from 100 ms to 200 s/div
Horizontal zoom "One Click Winzoom" system (direct graphical zoom on screen) x 1 to x 5 or x 100 – storage 100 kpts/channel
Triggering
Mode On all the channels: automatic, triggered, one-shot, auto level 50%
Type Edge, pulse width (16 ns-20 s), delay (48 ns to 20 s), counting (3 to 16,384 events) Continuous adjustment of Trigger position
Coupling AC, DC GND, HFR, LFR, noise – Level and Hold-Off adjustable from 64 ns to 15 s
Sensitivity 1.2 division p-p up to 300 MHz
Digital storage
Maximum sampling rate 2.5 GS/s in one-shot mode on each channel (100 GS/s max. in ETS mode)
Vertical resolution 12 bits (vertical resolution 0.025 %)
Memory depth 100 kpts per channel and le viewer in the manager
User storage File management
GLITCH mode Duration 2 ns – 500,000 Min/Max pairs
Display modes Envelope, vector, accumulation-, averaging (factors 2 to 64) – XY (vector) and Y(f)=FFT
Other functions
AUTOSET Complete in under 5 s, with recognition of the channels – Frequency > 30 Hz
FFT analyzer & MATH functions 2,500-point FFT (Lin or Log) with measurement cursors – Functions + , - , x , / and mathematical function editor
Cursors 2 or 3 cursors: simultaneous V and T with AUTO measurement: T1, T2, Dt, 1/Dt, dBV, Ph
Automatic measurements Simultaneously with waveform, 20 automatic measurements per channel and on the 4 channels simultaneously with scroll
MULTIMETER MODE
General specications 2 or 4 channels – 8,000 cts min/max/frequency/relative – TRMS – Time/date-stamped graphical recording in logger mode
AC, DC and AC + DC voltages 600 mV to 600 VRMS, 800 mV to 800 VDC – VDC accuracy +/- (0.5 % + 25 D) – 200 kHz bandwidth
Resistance 80 Ω to 32 MΩ – accuracy 0.5%R+ 25D – Quick continuity test < 10 ms
Other measurements Temperature (HX0035 = KTC, HX0036 = Pt100) / Capacitance 5nF to 5mF / Frequency 200 kHz / Diode test 3.3 V
Single and three-phase power Active, Reactive and Apparent power values plus Power Factor simultaneously with the U & I measurements
HARMONIC ANALYSER MODE
Multi-channel analysis 2 or 4 (depending on model), 63 orders, fundamental frequency 40 to 450 Hz in auto or manual mode
Simultaneous measurements Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms)
LOGGER MODE
Acquisition Duration: 20,000 s – Interval: 0.2 s – Files: 100,000 measurements
GENERAL SPECIFICATIONS
Conguration memories Not limited according to device - variable le sizes
Printing Network printing via Ethernet/Wi in .png format
PC communication – software link Ethernet (100 baseT), WiFi-USB (device, 12 Mbs) – "ScopeNet" application software for PC
Software
Mains power supply
Safety / EMC Safety as per IEC 61010-2-30, 2010 – 600V CAT III / 1000V CAT II – EMC as per EN61326-1, 2010
Mechanical specications 292.5 x 210.6 x 66.2 mm – 2.1 kg with batteries – IP54 protection
OX 9062 OX 9102 OX 9104 OX 9304
60 MHz 100 MHz 100 MHz 300 MHz
15 MHz, 1.5 MHz or 5 kHz bandwidth limiter
Internal = 1 GB to store the les: trace, text, conguration, math functions, System memory: .pdf print les, .png image les
+ high-capacity removable µSD-Card: SD 2 GB, SDHC 4-32 GB and SDXC > 32 GB
PC: Ethernet and USB, ScopeNet (remote control, data recovery, cursors and automatic measurements)
Android tablet – ScopeAdmin Fleet Administration utility
Li-Ion rechargeable battery (6,900mAH-40 Wh) – Battery life of up to 8 hrs – Adjustable standby mode
Adapter / 2-hour fast charger, universal 98-264 V / 50/60 Hz)
Call the AEMC® Instruments Technical Assistance Hotline for immediate consultation with an applications engineer: (800) 343-1391
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments • 200 Foxborough Blvd. • Foxborough, MA 02035 USA • (800 ) 343-1391 • (508 ) 698-2115 • Fax (508) 698-2118
Expor t Department: (603) 749-6434 (x520) • Fax (603) 742-2346 • E-mail: export@aemc.com • E-mail: sales @aemc.com
950.BR-OX9000Series_0519 Printed in the USA
Loading...