Aegis QuickSwitch CZ23002, QuickSwitch CZ23000, QuickSwitch CZ23001, QuickSwitch CZ23003, QuickSwitch CZ23004 Instruction Manual

...
INSTRUCTION MANUAL
CZ23000 SERIES
CZ02408-02
QuickSwitch™ – Instruction Manual
Congratulations on your purchase of an Aegis Pty Ltd
QuickSwitch™
We are sure you will be satisfied with its performance and reliability.
Please read this instruction carefully before using your
QuickSwitch™ and refer to these notes from time to time to ensur e
you are always familiar with its operation.
Safety Warning
Ensure the QuickSwitch™ (with already attached accessory plug), is
plugged into the IDS Module before any other connection is made.
Care must be taken at all times to ensure personal safety.
Aegis Pty Ltd can also supply many instruments for a number of applications to support installation and maintenance of cabling for the Telecommunications, Data and Electrical industries.
If you require further information on any of these instruments please contact us by way of phone, fax or e-mail.
200 Rooks Road, Vermont, Victoria 3133 AUSTRALIA
TELEPHONE: (03) 8872 6666 FACSIMILE: (03) 8872 6678
International Prefix +613
Email: sales@aegis.net.au
WEB: www.aegis.net.au
This Operators Manual covers the full CZ23000 Series of
QuickSwitch™. Refer to Section 2, for further details of each type
!
August 2009 Page 2 of 17 CZ02408-02
QuickSwitch™ – Instruction Manual
Table of Contents
1. SAFETY WARNINGS ......................................................................................................... 4
1.1. Warning Note .................................................................................................................. 4
1.2. Warning High Test Voltages ........................................................................................... 5
2. INTRODUCTION ................................................................................................................. 5
2.1. Intended use of QuickSwitch™ ...................................................................................... 5
2.2. Tests and Functions performed ....................................................................................... 6
2.3. Major features of the QuickSwitch™ ............................................................................. 6
2.4. Abbreviations and Definitions ........................................................................................ 6
3. GENERAL OPERATION EXPLANATION ..................................................................... 7
3.1. Features of the QuickSwitch™ ....................................................................................... 7
3.2. QuickSwitch™ Controls/ Layout .................................................................................... 7
4. OPERATING INSTRUCTIONS ......................................................................................... 8
4.1. Components Available .................................................................................................... 8
4.2. Switch Positions .............................................................................................................. 9
4.3. Use with General Test Equipment. ............................................................................... 10
4.4. Use with RJ Adaptor. .................................................................................................... 10
5. QUICKSWITCH™ OR ADAPTOR LEAD SETS AVAILABLE ................................. 11
6. SPECIFICATIONS ............................................................................................................. 13
6.1. Electrical ....................................................................................................................... 13
6.2. Environmental Conditions ............................................................................................ 13
6.3. Physical ......................................................................................................................... 13
6.4. Functions (QuickSwitch™) .......................................................................................... 13
6.5. Optional Accessories ..................................................................................................... 14
6.6. Applicable Standards .................................................................................................... 14
7. CARE AND MAINTENANCE .......................................................................................... 15
7.1. Warranty ........................................................................................................................ 15
7.2. Maintenance and Servicing ........................................................................................... 15
7.3. Cleaning ........................................................................................................................ 15
7.4. Calibration ..................................................................................................................... 15
August 2009 Page 3 of 17 CZ02408-02
QuickSwitch™ – Instruction Manual
1. SAFETY WARNINGS
* The QuickSwitch™ must only be used for the purpose, and in a manner, as described in these instructions. Failing to do so may impair the protection, function of or damage the product. * The QuickSwitch™ must be switched to the Monitor (Bridging) position and plugged into the IDS Module prior to any other connection being made. Ensure all Test equipment or instruments are removed from the QuickSwitch™ before the lead i s either ins erted or withdrawn from the IDS Module. Failing to do so may impair the protection provided by the QuickSwitch™. * The QuickSwitch™ offers the greatest protection after being plugged in and all connections are made, therefore the operator must use caution when handling the leads, ensuring the plug or socket contacts are not touched.
There are four warnings to be noted when using the QuickSwitch™. All relate to the connection interfaces which are highlighted by either of the following symbols on the switch base or connector head:
1. This symbol alerts the operator to refer to a Note in this handbook.
(Warning Note, See Section 1.1)
2. This symbol alerts the operator that High Test Voltages may be
present at this connection interface.
(Warning High Test Voltages, See Section 1.2)
1.1. Warning Note
When making any connection with QuickSwitch™, be aware that hazardous voltages may exist on the IDS terminal unit, cable pair or test leads of the equipment being used.
The QuickSwitch™ offers the greatest protection after being fully connected and all connections are made, th erefore the operator must use caution when handling the leads, ensuring the plug contacts are not touched. See Figure 1.1-1
Figure 1.1-1 Warning & High Voltage warning symbols on the connection Interfaces.
Warning
High Voltage warning
August 2009 Page 4 of 17 CZ02408-02
QuickSwitch™ – Instruction Manual
1.2. Warning High Test Voltages
It is important to recognize that any electrical/electronic system may present hazardous voltages. When making connection with the QuickSwitch™, care must be taken not to contact any potentially live parts. See Figure 1.1-1
2. INTRODUCTION
2.1. Intended use of QuickSwitch™
The QuickSwitch™ is intended for use by service personnel on the telecommunications network and under normal conditions is exposed to telecommunications network voltages. Should a fault condition occur with hazardous voltages on the network, the QuickSwitch™ offers protection to service personnel in form of basic insulation to a working voltage of 300 Vrms CAT II. The QuickSwitch™ is a connection tool for telecommunications networks. The QuickSwitch™ incorporates a rotary action control switch, which allows the operator to access a cable pair at an MDF, or CCU, etc., and in turn Monitor the cable pair before performing any test.
The operator then uses the switch to select the direction to conduct a test from this test point, either back towards the Exchange or out towards the Customer. An additional feature of the QuickSwitch™ is that they can also be used to access the Exchange side and Country side simultaneously.
Part Number Terminal Access:
CZ23001 QuickSwitch™. CZ23002 QuickSwitch™ Adaptor Siemens Series 71 Plug CZ23003 QuickSwitch™ Adaptor Siemens Series 2000 Plug CZ23004 QuickSwitch™ Adaptor Siemens Series 5000 Plug CZ23005 QuickSwitch™ Adaptor Crocodile Clips (4) Plug CZ23006 QuickSwitch™ Adaptor Krone Plug CZ23007 QuickSwitch™ Adaptor Madison Plug CZ23008 QuickSwitch™ Adaptor Plug 3M (Quante) CZ23009 QuickSwitch™ Adaptor Plug Marconi CZ23011 QuickSwitch™ Adaptor Plug RJ CZ23012 QuickSwitch™ Carry Pouch
Adaptor Leads available:
CZ2280 Banana Plug to RJ Plug (Butt Lead) CZ2285 Banana to RJ Socket Adaptor Lead CZ2301 Earth Plug (Complete Set)
Note 1: The Adaptor Leads provide test access to RJ sockets for both Data and Telephony circuit testing. Note 2: All leads are supplied individually or as a kit, as required.
August 2009 Page 5 of 17 CZ02408-02
QuickSwitch™ – Instruction Manual
2.2. Tests and Func ti ons performed
The QuickSwitch™ does not actually perform any tests itself, it facilitates the access required to a telecommunications network at a cross-connect point, to allow other test instruments to perform the tests as required. When switched to the Monitor position, with the appropriat e access pl ug, it can be inserted into the matching IDS module to allow the operator to monitor the line (Cable Pair) under investigation. This test is usually conducted with a Buttinski test set. By rotating the switch through the available positions marked on the switch body, the operator can then connect other test instruments to conduct the usual line tests to determine the “Line Condition”. Depending on which way the IDS Module and Access plug is setup, (See sections 4.2, for Accessing Exchange or Customer Side), the operator can select, with the rotary switch, the Exchange or Customer side for testing. By selecting the Exchange side, the line can be tested utilizing auto test facilities, or simply utilize the normal Exchange functions. When the Cus tomer Side i s sel ected, t he cable s ection lead ing out tow ards the cust omer can be checked or tested. In general, the QuickSwitch™ with all it’s optional plugs, is normally used by any Technician or Communication Officer, in the performance of their duties, where access to the copper line is required at any test point along the line. This can be between and including, the Exchange and the customer’s premises.
2.3. Major features of the QuickSwitch™
The major features allow the connection of any standard test instrument to a Telecommunication or Data Network via:
Line Access, non interrupting, Monitoring
Access to the Exchange side by simple switching without changing lead connections
Access to the Customer side by simple switching without changing lead connections
Access to both the Exchange and Customer individually at the same time, by simple
switching without changing lead connections.
Safety of the Operator from non-standard, dangerous voltages on the line
2.4. Abbreviations and Definitions
CAN Customer Access Network MDF Main Distribution Frame CCU Cross Connect Unit (Pillar or Cabinet) Country Country Side (also called Customer Side) - R efers to the cable looking
away towards the customer, from the test point.
Exchange (Exchange Side) - Refers to the cable looking back towards the
Exchange, from the test point.
August 2009 Page 6 of 17 CZ02408-02
Loading...
+ 11 hidden pages