AEG Identifikationssysteme AREH9LF-1, URH1LL, URH1LA User Manual

Page 1
Revision 008
User Guide
ARE H9 Full-ISO Pocket Reader
---------------------------------------------------------------1/36---------------------------------------------------------------
Page 2
1 INTRODUCTION 4
2 ELEMENTS OF THE ARE H9 5
3 OPERATION GUIDE 6
3.1 Installation of the battery 6
3.2 Power on / off 6
3.3 Reading a transponder in standard mode 7
3.4 Reading Range 8
4 DATABASE 9
5 MENU FUNCTIONS 9
5.1 Navigating the trough the menu function 9
5.2 Overview of the menu functions 10
5.3 Set Attribute 11
5.4 Operating mode 12
5.4.1 Standard mode 12
5.4.2 Online/USB
5.4.3 Online/USB H or Online/BT H*) mode – handshake mode 14
5.4.4 Database/USB or Database/BT*) mode. 15
5.5 Set Interface /Bluetooth Selection (only with optional Bluetooth-module) 16
5.5.1 Interface USB
5.5.2 Set Interface to Bluetooth Slave 17
5.5.3 Set Interface to Bluetooth Master 18
5.5.4 Bluetooth Disconnect 20
**)
or Online/BT*) mode 12
**)
16
5.6 Lock Up Reader 20
5.7 Set Code Format 21
5.8 Erase Memory 22
5.9 Reading time 23
5.10 Turn-off time 23
---------------------------------------------------------------2/36-------------------------------------------------------------
Page 3
5.11 Turn-on delay 24
5.12 Keyboard Sound 24
5.13 Set Time (available only with Real-Time-Clock module expansion) 25
5.14 Set Date (available only with Real-Time-Clock module expansion) 26
5.15 Language/Sprache – select display language 27
5.16 Reader-Version 27
6 USB DRIVER INSTALLATION
6.1 Virtual RS232 Com Port 30
6.2 COM Port Setup with Windows Device Manager 30
*) ***)
27
7 USB INTERFACE CONFIGURATION USED IN ONLINE AND DATABASE
MODE 33
8 RS232 INTERFACE SETTINGS
**)
33
9 CONTROL CHARACTERS USED IN THE ONLINE MODE 33
10 TECHNICAL SPECIFICATIONS 34
11 OPERATION WITH OTHER RF ID EQUIPMENT 34
12 SAFETY INSTRUCTION 35
13 FCC INFORMATION 35
14 NOTIFICATION OF CHANGES 36
15 CONTACTS 36
---------------------------------------------------------------3/36-------------------------------------------------------------
Page 4
1 Introduction
The ARE H9 is a RFID Pocket Reader designed to read passive Read-Only-Transponder. It has the ability to store the Transponder-Codes in its internal database.
This Pocket Reader is equipped with a USB Interface
**)
, which allows transmitting single transponder codes
or its entire database to a computer.
It is especially suitable for animal identification, logistics and asset tracking
The ARE H9 Full-ISO is capable to read the following transponder types:
FDX-B Read-Only(according to ISO 11784/11785)
HDX-B Read-Only(according to ISO 11784/11785)
Trovan
PSK1
ASK64bit
The ARE H9 does not synchronize with other RFID readers operating in close vicinity.
Before the initial use of this ARE H9 reader please study this manual carefully.
**)
RS232 Interface in Rs232 version
---------------------------------------------------------------4/36-------------------------------------------------------------
Page 5
2 Elements of the ARE H9
Antenna Position
2x16 Character
LCD-Display
Menu Options Buttons
(left, menu, right)
Main Button
(read, select)
USB Connector **)
Battery
Compartment
**)
RS232 cable in Rs232 version
---------------------------------------------------------------5/36-------------------------------------------------------------
Page 6
3 Operation Guide
3.1 Installation of the battery
Slide door of the battery compartment to open it.
Attach the Battery to the connector inside. Put the Battery into the compartment.
9V Block
Battery
Slide the door back to close it. Use only 9V E-Block alkaline Batteries of the Type 6LR61.
+
-
Battery-clip
3.2 Power on / off
The Pocket Reader is switched on by pressing the main button for 0,5s (default). The reader starts in reading mode.
The ARE H9 will switch off automatically after 20s (default) when no button has been pressed within this time.
---------------------------------------------------------------6/36-------------------------------------------------------------
Page 7
3.3 Reading a transponder in standard mode
Press the main button to start the reading process.
The ARE H9 starts the reading process and the display shows:
actual
count
0 of 2016
Scanning Nr. 1
Approach a transponder within the readers reading range.
The reader emits a beep when the transponder has been read successfully, and the transponder code is shown on the display:
Country-Code ID
maximum
count
969 0000000001024 1 12
Retagging Counter and User Information
For ISO Transponder additional the retagging counter and the user information field are displayed in the second row of the display.
In case no transponder has been read within the given time frame, the reader stops its reading process and the display shows:
--- No Tag ---
For further reading processes release the main button and press it again for each attempt.
---------------------------------------------------------------7/36-------------------------------------------------------------
Page 8
3.4 Reading Range
The reading range and distance depends on the transponder, its packaging and orientation to the reader. The following diagram shows the typical area where a glass transponder should be read:
The ARE H 9 is not capable to read two or more transponders which are at the same time in the antenna field.
---------------------------------------------------------------8/36-------------------------------------------------------------
Page 9
4 Database
When a reading had been accomplished successfully, in the standard operating mode, the ARE H9 internal database will be checked whether this transponder code is already stored. If the new code, in combination with the attribute, is not found in the database, it will be stored as a new record. This record is composed of the ID-code, the transponder type, the selected attribute. With the optional real time clock module date and time of reading will be also stored. If the new code is already stored in the database, it will be not stored again. In this case the reader emits 2 successive beeps. The database is capable to store up to 2016 transponder codes. When the maximum of the storage is reached no further new code is stored. To store new codes in this case the database has to be erased. The database of the ARE H9 with all its actual records could be transmitted to a PC; also it is possible to receive a new database from a PC. This is done in the Database/USB mode described in chapter 5.4.4. On Power Loss the ARE H9 will keep its database data.
5 Menu Functions
5.1 Navigating the trough the menu function
By pressing the menu button it can be chosen between the different menu function. If the menu button is pressed again the ARE H9 cyclic changes to the next menu function.
Inside a menu function the setting for the function could be changed with the arrow buttons.
With the main button the actual menu function setting is selected and the ARE H9 changes back to the transponder reading mode.
---------------------------------------------------------------9/36-------------------------------------------------------------
Page 10
5.2 Overview of the menu functions
--- No Tag ---
Set Attribute #
Operating Mode Standard
Set Interface USB
Lock Up Reader Unlocked
Set Code Format ISO Animal
Erase DB-Memory Confirm ?
Reading Time
2.0 s
01 Jan '10 12:00:00
Set Attribute A
Operating Mode Online/USB
Set Interface Bluet. Slave
Lock Up Reader Lock
Set Code Format ISO Industry
Press both arrow
buttons to erase
database memory
+ 0.5 s
- 0.5 s
available only with Real-
... ...
Operating Mode Online/USB H
Set Interface Bluet. Master
Set Code Format BDE-Format
Time-Clock module
Set Attribute Z
Operating Mode Datenbank/USB
available only with optional Bluetooth
module
Set Code Format ISO Attributs
Set Code Format Hexadecimal
Turn-Off Time 20 s
Turn-On Delay
0.5 s
Keyboard Sound On
Set Time 12:00:00
Set Date 01 Jan '10
Language/Sprache English
AEG ID - ARE H9 V3.00200
+ 5 s
- 5 s
+ 0.5 s
- 0.5 s
Keyboard Sound Off
available only with
Real-Time-Clock
module
Language/Sprache Deutsch
Press the main button to select
actual menu option
---------------------------------------------------------------10/36-------------------------------------------------------------
Page 11
5.3 Set Attribute
With set attribute one of 27 attributes could be selected for the next read transponder.
The selection is done by the left/right arrow buttons and confirmed by pressing the main button.
Set Attribute #
In standard read mode this selected attribute will be stored together with the transponder ID­code of the next read transponder in the internal database of the ARE H9. When the Code Format is set to Attributes will the selected attribute or its text displayed in the rightmost corner of the second display line.
Example of Transponder-ID with no attribute:
Country-Code ID
969 0000000001024 ISO-Fdx #
type of trasnponder
In the initial configuration all the 27 attributes available have a standard text assignment.
#, A, B, C,D,E,F,G,H,I,J,K,L,M,N,O,P,Q,R,S,T,U,V,W,X,Y,Z
With a PC-software and using the Database/PC mode of the ARE H9 it is possible to assign each attribute a custom text with up to 14 ASCII characters.
Example: A becomes "stable", B becomes "pasture" C becomes "vaccination"
Under Set Attribute at the ARE H9 it is now possible to select the attribute by this custom text.
When a transponder has been read with a attribute set up with a custom text, the text assigned to the attribute will now be shown on the lower line of the display, right justified, instead of the attribute.
attribute
---------------------------------------------------------------11/36-------------------------------------------------------------
Page 12
Example of Transponder-ID with attribute and assigned text “Stall”:
Country-Code ID
969 0000000001024 ISO-Fdx Stall
attribute
type of transponder
5.4 Operating mode
The menu "Operating Mode" switches between the following modes: Standard, Online/USB mode and Database/USB mode.
Operating Mode Standard
5.4.1 Standard mode
In the standard mode will the read transponder codes stored into the internal database of the ARE H9. For a detailed description see section 3.3 and 4.
5.4.2 Online/USB
In the online mode the transponder codes will not be stored into the internal database of the ARE H9. The transponder codes are immediately transmitted via the USB interface to an attached PC, PDA, etc.
It is important that there is a USB ready to receive the data; otherwise the read transponder codes are lost because they are not stored in this mode.
The reading process is the same as in standard mode; the second display-line shows the information of the selected “online/USB” processes.
**)
or Online/BT*) mode
**)
or Bluetooth*) connection established to a host-device
**)
**)
or “online/BT” mode in between the reading
*)
only with optional Bluetooth module
Ser. for Rs232 version
---------------------------------------------------------------12/36-------------------------------------------------------------
Page 13
The data format used in online mode to transmit the transponder codes is as follows:
Example:
ASCII
Hexadecimal
STX A 1 1 2 0 0 0 9 6 9 0 0 0 0 0 0 0 0 1 0 2 0 CR LF
02 31 31 31 32 30 30 30 39 36 39 30 30 30 30 30 30 30 30 31 30 32 30 0D 0A
The transponder code is transmitted as ASCII string the transmission is completed by the control characters <CR> <LF>.
The online mode could be terminated by choosing another mode selection within the operation mode menu.
Once the online mode is active, the ARE H9 will be automatically in the online mode when it switched on again after switched off.
---------------------------------------------------------------13/36-------------------------------------------------------------
Page 14
--- No Tag ---
- Online/USB -
Scanning ...
- Online/USB -
969 0000000001024
- Online/USB -
To leave the mode “Online/USB” under “Operating Mode” another mode has to be selected
5.4.3 Online/USB H or Online/BT H*) mode – handshake mode
The “online/USB H” or “online/BT H” mode has a similar to the “online/USB” with the difference that a read transponder code will not be sent immediately to the host (PC, PDA, etc.). First the reader checks if a connection to the host is established before it sends the transponder code.
*)
only with optional Bluetooth module
**)
online/ser. for Rs232 version
---------------------------------------------------------------14/36-------------------------------------------------------------
Page 15
For this transmission the following protocol is used:
ARE H9 Host (PC, PDA, etc.)
<STX> <ETX> -> <- <STX> <ACK> <ETX> <STX> < transponder data > <ETX> -> <- <STX> <ACK> <ETX>
If transponder ID was read the following is displayed:
999 000000000000 transmitting...
Does the host not answering to the <STX> <ETX> protocol of the ARE H9, then the ARE H9 will cyclic transmitting the <STX> <ETX> protocol until an answer of the host would be received. During this the following display appears:
Await Connection Abort ?
The user can cancel this waiting for a response of the host by pressing both arrow buttons, but in this case the transponder ID will not transmitted.
5.4.4 Database/USB or Database/BT*) mode.
In the database mode it is not able to read a transponder. It is intended to transmit and receive record sets of the ARE H9 internal database to a host device as a PC, PDA, etc. To exchange data in the database mode a software called reader-terminal included with the ARE H9.
The usage of this software and the communication protocol is explained in an extra document included with the software. The database mode could be terminated by pressing both arrow buttons simultaneously, or by initiating it by the PC-communication
Communic. Active Abort ?
During the Database/PC mode the ARE h9 will not switch off automatically.
---------------------------------------------------------------15/36-------------------------------------------------------------
*)
only with optional Bluetooth module
**)
database/ser. for Rs232 version
Page 16
5.5 Set Interface /Bluetooth Selection (only with optional Bluetooth-
module)
This menu option is enabled with an installed Bluetooth module to switch between USB and Bluetooth and to choose the Bluetooth connection method:
- USB
- Bluetooth Slave
- Bluetooth Master
Set Interface USB
Set Interface Bluet. Slave
Set Interface Bluet. Master
The ARE H9 supports only Bluetooth connection with the serial Port profile.
5.5.1 Interface USB
**)
USB is the default configuration of the ARE H9. With this option enabled the complete communication to and from the ARE H9 is done by the USB cable connection. Choosing USB as interface automatically disables the any active Bluetooth connection,
**)
serial for Rs232 version
---------------------------------------------------------------16/36-------------------------------------------------------------
Page 17
5.5.2 Set Interface to Bluetooth Slave
This menu option configures the ARE H9 as Bluetooth slave. With the ARE H9 as Bluetooth Slave the Bluetooth-connection is established up by the Bluetooth-partner which is configured as master. The ARE H9 checks after the selection of this option if there is an active Bluetooth connection, in this case this connection will be closed. Then the ARE H9 is waiting until a Bluetooth connection is established or the user cancels the operation by pressing both arrow buttons. During this operation the ARE H9 will not switch off automatically.
Set Interface Bluet. Slave
Verify Blutooth Connection
Closing active Connection
Await Connection Abort ?
Connected as BT Slave
---------------------------------------------------------------17/36-------------------------------------------------------------
Page 18
5.5.3 Set Interface to Bluetooth Master
This menu option configures the ARE H9 as Bluetooth master. In this configuration an Bluetooth connection with an partner is established by the ARE H9. In case there is still an active Bluetooth connection, this connection will be closed before a new one is established.
Set Interface Bluet. Master
Verify Bluetooth Connection
Closing active Connection
BluetoothPartner PC_007
Was there a Bluetooth partner for the master connection configured before, this partner will be displayed as default option in the following dialog.
BluetoothPartner PC_007
By pressing the arrow keys it is possible to switch the selection between the default partner and a new partner search.
By choosing the default partner, the ARE H9 will try to establish a connection. During this process the message “Await Connection” could appear, this is the case when the partner is not ready or at the partner side additional activities are necessary.
BluetoothPartner new search
---------------------------------------------------------------18/36-------------------------------------------------------------
Page 19
BluetoothPartner PC_007
BT Connecting to PC_007
Await Connection Abort ?
Connected with PC_007
“new Search” starts a search process for Bluetooth devices in range of the ARE H9. The Bluetooth device search could last some seconds.
BluetoothPartner new search
Bluetooth Search
2
New BT Partner PC_007
BT connecting to PC_007
Await Connection Abort ?
Connected with PC_007
---------------------------------------------------------------19/36-------------------------------------------------------------
Page 20
Was the search successful a selection of possible partners will be shown. The Bluetooth partner search can’t detect if a Bluetooth device supports the serial port profile, the user has to know this. Was the search not successful the ARE H9 switches back to the “Set Interface” menu.
After choosing a partner from the found devices, the ARE H9 will try to establish a connection. During this process the message “Await Connection” could appear, this is the case when the partner is not ready or at the partner side additional activities are necessary.
A successful connection will be shown as follows:
Connected with PC_007
5.5.4 Bluetooth Disconnect
Is the connection to the Bluetooth partner lost during the operating of the ARE H9, or maximum Bluetooth distance has exceeded, the following display appears:
Await Connection Abort ?
In this case will the ARE H9 wait as long as the connection is established again ort he user cancels this screen by pressing both arrow buttons.
While switching off the ARE H9 the Bluetooth connection to a partner will automatically disconnected.
5.6 Lock Up Reader
When lock up reader is activated the ARE H9 switches of immediately. After switching on the pocked reader again it shows that it is locked. During the ARE H9 is locked neither a reading process could started nor the menu could be accessed. While it is not unlocked, it will switch off again after 5 (default) seconds no button is pressed. To leave this mode press both arrow buttons simultaneously.
Unlock Reader ! Press Both
---------------------------------------------------------------20/36-------------------------------------------------------------
Page 21
5.7 Set Code Format
This menu option sets the format of representation of ISO-code. The ARE H9 currently supports three code formats.
ISO Animal code format for ISO-FDX and ISO-HDX ISO Industry code format for ISO-FDX and ISO-HDX ISO BDE code format for ISO-FDX for waste management ISO Attributs for ISO-FDX and ISO-HDX with attribute display
(Like the former H5 display)
Hexadecimal for Trovan, PSK1, ASK 64bit, ISO-FDX and ISO-HDX
Set Code Format ISO Animal
The selection sets the way in which the transponder code is displayed. This option has no influence to the reading function; it only filters how the read ID-code is displayed. This setting has only impact to ISO-FDX and ISO HDX transponders. For example, if code format is set to “ISO-Animal” and an ISO transponder without animal bit is read the ARE H9 will signal this with 3 beeps and the following display:
No ISO Animal ISO-Fdx
The ARE H9 selects automatically the hexadecimal display if a Trovan, PSK1 or Ask64Bit transponder is read. This setting is stored in the device and is still valid after power off/on operation.
---------------------------------------------------------------21/36-------------------------------------------------------------
Page 22
5.8 Erase Memory
This function allows deleting all records in the internal database of the ARE H9. For safety reasons this function is activated only when both arrow buttons are pressed simultaneously.
Erase DB-Memory Confirm ?
Erase DB-Memory erasing...
~15
seconds
Erase DB-Memory DB erased !
--- No Tag ---
The erasing of the database memory can take several seconds.
! Do not disconnect the ARE H9 from the power supply during this erase operation; this
could lead to damaging the database function of the reader.
After the erase operation has finished the device will return to the standard operating mode.
---------------------------------------------------------------22/36-------------------------------------------------------------
Page 23
5.9 Reading time
This sets the time frame for one reading attempt. The time could be changed with the arrow buttons in 0,5s steps. A new time is set by pressing the main button.
Reading Time
2.0 s
Default value 4 s min. value 0,5 s max. value 12,5 s
This setting is stored in the device and is still valid after power off/on operation. For optimal reading performance this setting is recommended to be between 2-4 seconds.
5.10 Turn-off time
Sets the time until the ARE H9 will automatically shut off while no button is pressed or activity lasts. It could be change with the arrow buttons in 5s steps.
Turn-Off Time 20 s
A new time is set by pressing the main button.
Default value 20 s min. value 10 s max. value 300 s
This setting is stored in the device and is still valid after power off/on operation.
---------------------------------------------------------------23/36-------------------------------------------------------------
Page 24
5.11 Turn-on delay
Sets the time the main button is to be pressed to switch on the ARE H9. The time could be changed with the arrow keys in 0,5s steps.
Turn-On Delay
0.5 s
A new time is set by pressing the main button.
Default value 0,5 s min. value 0 s max. value 5 s
This setting is stored in the device and is still valid after power off/on operation.
5.12 Keyboard Sound
Here the beep sound of the keyboard could turn on or off.
Keyboard Sound On
This setting is stored in the device and is still valid after power off/on operation.
---------------------------------------------------------------24/36-------------------------------------------------------------
Page 25
5.13 Set Time
This menu option sets the time of the optional Real-Time-Clock module expansion. With this expansion module it is possibly to add a time and date code, of reading, to the transponder ID in the database. The Real-Time Clock module is equipped with a own backup-battery to hold the time and date even if the ARE H9 is switched off or the main battery of the ARE H9 has to be changed. To set the time press select this option with the main button, now is it possible to change the hours with the left/right arrow button. The hour setting is accepted by pressing the main button; the ARE H9 switches now the minute setting. The minute and second setting is working in the same way as the hour setting. After setting the second the Real-Time-Clock will be synchronized with this new time. To abort the processes during Set Time press the menu button.
(available only with Real-Time-Clock module expansion)
Set Time 12:00:00
Set Hour
+ 1 h
12 00:00
- 1 h
Set Minute
+ 1 m
12 00 00
- 1 m
+ 1 s
Set Second 12:00 00
- 1 s
---------------------------------------------------------------25/36-------------------------------------------------------------
Page 26
5.14 Set Date
This menu option sets the date of the optional Real-Time-Clock module expansion. To set the date press select this option with the main button, now is it possible to change the day of month with the left/right arrow button. The day setting is accepted by pressing the main button; the ARE H9 switches now the month setting. The month and year setting is working in the same way as the day setting. After setting the second the Real-Time-Clock will be synchronized with this new date. To abort the processes during Set Date press the menu button.
(available only with Real-Time-Clock module expansion)
Set Date 01 Jan '10
Set Day
+ 1 d
01 Jan '10
- 1 d
+ 1 m
Set Month 01 Jan '10
- 1 m
Set Year
+ 1 y
01 Jan 10
- 1 y
---------------------------------------------------------------26/36-------------------------------------------------------------
Page 27
5.15 Language/Sprache – select display language
With this menu option is it possible to change the language of the ARE H9 menu-display.
Language/Sprache English
5.16 Reader-Version
This menu option shows the Firmware Revision of the ARE H9.
AEG ID - ARE H9 V3.00136
6 USB driver installation
To use the online and the database mode the ARE H9 is connected via USB to a host PC. Before the USB connection could be used a USB to RS232 bridge drive has to be installed.
Insert the driver disc supplied with the ARE H9 into your CD-Rom or DVD-Drive of the host PC you want to use with the pocket reader. Connect the ARE H9 with the supplied USB cable to a free USB port of your PC (USB1.1 and USB2.0 ports are supported).
USB connection cable
*) ***)
PC
ARE H9
*)
***)
forHID Version driver installation is described in the extra documenation
---------------------------------------------------------------27/36-------------------------------------------------------------
not for Rs232 version
Page 28
USB Device Driver
The PC will detect a new hardware; Windows opens the Found New Hardware Wizard.
If the Found New Hardware Wizard asks to connect to Windows Update, select „No, not this time“, then click „Next“.
---------------------------------------------------------------28/36-------------------------------------------------------------
Page 29
In the next windows of the Hardware Update Wizard select „ Install from a list or specific location (Advanced)“.
In the search dialog choose „Search for best driver in these locations“. Specify the CP210x driver located in the CD folder „..\USB_RS232_bridge_driver“.
Click „Next“after setting the path to the driver location
This completes the installation of the USB Device Driver.
---------------------------------------------------------------29/36-------------------------------------------------------------
Page 30
6.1 Virtual RS232 Com Port
After installing the USB Device Drive Windows automatically starts the installation of the virtual RS232 Com Port.
Do this installation with the Windows New Hardware Wizard in the same way as with the
USB Device Driver.
6.2 COM Port Setup with Windows Device Manager
After the installation of the USB Device Driver the COM port setting could be set and verified by the Windows Device Manager.
Open the Device Manager using start button -> select Run, type in the text field „devmgmt.msc“and click „OK“.
Another method is to access the Windows Device Manager is: Start -> Control Panel -> System
-> Hardware -> Device Manager.
---------------------------------------------------------------30/36-------------------------------------------------------------
Page 31
The COM driver for the ARE H9 is located under Port (COM & LPT):
„CP2101 USB to UART Bridge Controller (COMx)“
COMx stands for the COM port selected by the driver, this COM port could used in the software to communicate with the ARE H9.
In case there is a COM port conflict or another port number is needed, the COM port number has to be changed.
---------------------------------------------------------------31/36-------------------------------------------------------------
Page 32
To change the COM port, double click on „Ports (COM & LPT) - CP210x USB to UART Bridge Controller “.The Properties dialog will open.
Select the „Port Settings“ tab and click on the „Advanced“ button.
Select under „COM Port Number“ the port number to use, then clock „OK“.
---------------------------------------------------------------32/36-------------------------------------------------------------
Page 33
character
value
F
unction
7 USB Interface Configuration used in online and database mode
The USB connection to the ARE H9 is established as an additional com port via a USB bridge driver on the host PC. The protocol uses the RS232 specification with the settings:
19200 Baud, 8 Data bits, no party bit, one stop bit, no hardware handshake.
8 RS232 Interface Settings
If the ARE H9 Rs232 is used on a PC a Rs232-Crossover (lines Rxd, Txd are crossed) is necessary. In Operation Mode “Database/Ser.” and “online” are the following communication settings in use:
9600 Baud, 8 Data bits, no party bit, one stop bit, no hardware handshake.
**)
9 Control Characters used in the online mode
hexadecimal
<NL> 0x00 zero character, terminates text element
<STX> 0x02 start of text
<CR> 0x0D carriage return
<LF> 0x0A line feed
**)
only in Rs232 version
---------------------------------------------------------------33/36-------------------------------------------------------------
Page 34
electrical characterristic
environment
D
imensions
10 Technical Specifications
reading system ISO FDX-B, ISO-HDX, Trovan, PSK1, ASK64Bit
operational frequency 134,2 kHz
display LCD: 2-line by 16 charcaters
interface USB
user memory 2016 Codes with attribute, type, text, with optional real time
clock date and time
software AEG ID Terminal PC-Software
power supply 9V alkaline battery Typ 6LR61
storage temperature -10°C up to +70°C
operation temperature 0°C up to +55°C
housing protection IP 50
weight 185 g
length 135 mm
width 70 mm
height 24 mm
material ABS
11 Operation with other RF ID Equipment
As there may be electromagnetic interference between different readers, this reader shall not be operated within a distance of 3m from any other RFID reader. Otherwise a proper reading result cannot be guaranteed.
---------------------------------------------------------------34/36-------------------------------------------------------------
Page 35
12 Safety Instruction
The manufacturer can not be held liable for damages caused by improper use or abuse, lack of reasonable care, or manipulations contrary to the recommendations given in this manual. Do not open the reader! There are several spots inside the device, where high voltage is generated during the scanning process. The ARE H9 Reader does not contain any parts to be repaired by the user. Any attempt to open the reader may damage the device. Therefore it may be repaired only by authorized personal. Environmental conditions, as given in section 10, have to be observed during storage and operation. Protect the USB interface socket against dirt, moisture and dust. For cleaning of the reader and cable use a moistened towel. Never use chemical solvents like e.g. acetone. Do not submerge the reader in water.
13 FCC Information
Federal Communications Commissions (FCC) Statement
15.21
You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment.
15.105(b)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
---------------------------------------------------------------35/36-------------------------------------------------------------
Page 36
revision
date
description of changes
Editor
14 Notification of changes
001 16.02.2010 first revision HL
002 07.04.2010 Bluetooth option added
Some corrections
003 21.08.2012 Addition for Serial Version HL
004 10.09.2012 Rs232-Configuration added HL
005 17.10.2012 index added HL
006 9.12.2015 Reader Terminal MM
007 19.05.2016 FCC Information MK
008 17.06.2016 FCC Information correction MK
HL
15 Contacts
To improve our products, as well as its documentation is our permanent effort. For any questions, feedback or comments please call: Tel.: ++49 (0)731-140088-0
Fax: ++49 (0)731-140088-9000 e-mail: sales@aegid.de http:\ www.aegid.de
---------------------------------------------------------------36/36-------------------------------------------------------------
Loading...