Lux Products Cross Reference Chart
Single Stage Cooling & Two Stage Heating Heat Pumps
Not using Common Wire
HEAT PUMP SYSTEM NEW THERMOSTAT AN
NO COMMON TERMINAL CORRESPONDING TERMINAL
EG
ARCO / Friedrich X2 G Y RC W2 B C L
ARCO / Snyder General E G Y R O W1 C X
BARD E G Y1 R W2 B X L
BARD, HP, WH, MHP, HPQ E G Y R W2 W1 X L
BDP / BRYANT E G Y R O W1 C F
CARRIER E G Y R O Y1 C L
CARRIER 5Q to W2 G Y, W1 R O W2 C L
CARRIER 50Q, QT382 E G Y R O W2 C L
COLEMAN G Y RED V W2 BLCK
GE BAY X2 G Y R O W B T
HEIL-QUAKER / Whirpool G Y R O W B
JANITROL / Goodman E G Y R O W2 C
LENOX TYPICAL HP6 F M V/VR R Y X
LENOX HP8 E F M V/VR R Y X
LENOX HP9, 10 E F M V/VR R Y X L
LENOX HP16, 18, 19 E F M V/VR R Y X L
MAGIC CHEF PE E G Y R O W C
RHEEM / RUUD E G Y R W2 B X L
SNYDER GENERAL
H-R811/Y594R1375 G Y R O W1 C
TRANE X2 G Y R O W B F T
WEATHERKING G W1 R Y1 E C
WESCO E G W1 R Y1 W2 C
WESCO / ADDISON E G W1 R O X
WESTINGHOUSE H50 E G Y R O W X L1
WESTINGHOUSE HE F C V/VR H2 Z X
WHITE RODGERS E G Y R O W2 C L
WHITE RODGERS E G Y R O W2 X1
YORK G Y
Important: Use either the B or O terminal, never both.
For use with Models: PSDH105, DHP2110, LHP750*, PSDH121*, PSPH521*, HP2110, PSPH605
Thermostats with ( * ) the COMMON wire can be wired to the C terminal. Thermostats without the ( * ) DO NOT
USE COMMON, tape it OFF.
R
OW2B C L
OW B X
TAPE OFF
NOT USED