AEG-Electrolux 5618D-D, 511D-D, 511D-G, 5618D-W, 561D-D User Manual

...

Specifications and Main Features

  • Dimensions:
  • Height: 137 mm
  • Width:
  • 511 D, 561 D: 510 mm
  • 5618 D: 710 mm
  • Depth: 285 mm
  • Weights:
  • 511 D: 7.5 kg
  • 561 D: 9.0 kg
  • 5618 D: 10.5 kg
  • Fixed Loads:
  • Total fixed load:
  • 511 D, 561 D, 5618 D: 295 W
  • Fan motor: 2x 140 W
  • Lighting:
  • 511 D, 561 D: 14 W max E14 candle lamps
  • 5618 D: 15 W max fluorescent lamps
  • Length of power cable: 115 cm
  • Fan Outputs (to FMA 399, for 120 mm dia. exhaust air system):
  • Setting 1:
  • 511 D: - exhaust air: 130 m³/h, return air: 80 m³/h
  • 561 D: - exhaust air: 175 m³/h, return air: 131 m³/h
  • 5618 D: - exhaust air: 175 m³/h, return air: 131 m³/h
  • Setting 2:
  • 511 D: 255 m³/h
  • 561 D: 200 m³/h
  • 5618 D: 255 m³/h

-Setzeinung 3 (max):

  • 511 D: 410 m³/h
  • 561 D: 410 m³/h
  • 5618 D: 410 m³/h
  • Accessories:
  • 4 screws
  • 1 cap (white or brown)
  • Active carbon filter
  • Safety
  • Requirements

1. Installation performed by certified electrician

2. Provision of automatic circuit breakers and appropriate connections

Frequently Asked Questions

  • Which lamps are used in the fume extractor hood?

The fume extractor hood means remark ‘E14 candle lamps 14 W maximum’ used.

  • For what purposes can the hood be utilized?

The hood can be used as a return air appliance with an active carbon filter which is a special accessory, can be fitted.

  • What is the procedure for maintaining grease filters?

Treated grease filters in dishwashers on the powerful programme should be washed every four weeks or they should be washed in hot water and grease removing detergent every four weeks.

  • How can find faults in the working of the fume extractor hood?

For working out the issue contact the after sales service mentioning model designation E-No and F-No available on rating plate just after opening of fat filter grille inside the appliance.

  • Can the appliance be placed over a gas stove?

It can, but as a precaution, it should be mounted more than 700 mm over the coal and oil stoves and 650 mm over the gas stoves.

User Manual

AEG-Electrolux 5618D-D, 511D-D, 511D-G, 5618D-W, 561D-D User Manual
Loading...
+ 16 hidden pages