Thank you for choosing a fi rst class
product from Electrolux, which hopefully will provide you with lots of pleasure
in the future. The Electrolux ambition is
to offer a wide variety of quality products that make your life more comfortable. You fi nd some examples on the
cover in this manual. Please take a few
minutes to study this manual so that
you can take advantage of the benefi ts
of your new machine. We promise that
it will provide a superior User Experience delivering Ease-of-Mind.
Good luck!
Page 4
4 electrolux Recommendations and Suggestions
RECOMMENDATIONS AND SUGGESTIONS
Installation
• The manufacturer will not be held liable for any damages resulting from
EN
incorrect or improper installation.
• The minimum safety distance between the cooker top and the extractor hood is 650 mm.
• Check that the mains voltage corresponds to that indicated on the rating
plate fi xed to the inside of the hood.
• For Class I appliances, check that the
domestic power supply guarantees
adequate earthing.
Connect the extractor to the exhaust
fl ue through a pipe of minimum diameter 120 mm. The route of the fl ue
must be as short as possible.
• Do not connect the extractor hood to
exhaust ducts carrying combustion
fumes (boilers, fi replaces, etc.).
• If the extractor is used in conjunction
with non-electrical appliances (e.g.
gas burning appliances), a suffi cient
degree of aeration must be guaranteed in the room in order to prevent
the backfl ow of exhaust gas. The
kitchen must have an opening communicating directly with the open air in
order to guarantee the entry of clean
air.
Use
• The extractor hood has been designed exclusively for domestic use to
eliminate kitchen smells.
• Never use the hood for purposes
other than for which it has ben designed.
• Never leave high naked fl ames under
the hood when it is in operation.
• Adjust the fl ame intensity to direct it
onto the bottom of the pan only, making sure that it does not engulf the
sides.
• Deep fat fryers must be continuously
monitored during use: overheated oil
can burst into fl ames.
• Do not fl ambè under the range hood;
risk of fi re
• The hood should not be used by children or persons not instructed in its
correct use.
Maintenance
• Switch off or unplug the appliance
from the mains supply before carrying
out any maintenance work.
• Clean and/or replace the Filters after
the specifi ed time period.
• Clean the hood using a damp cloth
and a neutral liquid detergent.
The symbol on the product or on its
packaging indicates that this product may
not be treated as household waste. Instead
it shall be handed over to the applicable
collection point for the recycling of electrical
and electronic equipment. By ensuring this
product is disposed of correctly, you will help
prevent potential negative consequences for
the environment and human health, which
could otherwise be caused by inappropriate
waste handling of this product. For more
detailed information about recycling of this
product, please contact your local city offi ce,
your household waste disposal service or
the shop where you purchased the product.
8 1 Directional Air Outlet grille
10 1 Adapting ring ø 120-125 mm
20 1 Closing Element
Ref. Q.ty Installation Components
12a 4 Screws 4,2 x 44,4
12e 2 Screws 2,9 x 9,5
Q.ty Documentation
1 Instruction Manual
12a
1
ø 120
EN
175
280
0÷152
12e
8
10
20
Page 6
6 electrolux Installation
INSTALLATION
Drilling the Support surface and
Fitting the Hood
EN
SCREW FITTING
• The hood support surface must be
135 mm above the bottom surface of
the wall units.
• Drill the support with a ø 4,5 mm drill
bit, using the drilling template provided.
• Cut a hole ø 125 mm in size on the
support surface, using the drilling
template provided.
• Fix using the 4 screws 12a (4,2 x
44,4) provided.
SNAP-ON FITTING
• The hood can be installed either directly on the bottom surface of the
wall units (min. 650 mm above the
hob) using snap-on side supports.
• Cut a fi tted opening in the bottom
surface of the wall unit, as shown.
• Insert the hood until the side supports
snap into place.
• Lock in position by tightening the
screws Vf from underneath the hood.
12a
30
125125
135
264
15
502
Vf
CLOSING ELEMENT
• The space between the edge of the
hood and the rear wall can be closed
by applying the element 20 provided,
using the screws supplied for this purpose.
20
Page 7
Connections
Installation electrolux 7
DUCTED VERSION AIR EXHAUST
SYSTEM
When installing the ducted version, connect the hood to the chimney using either a fl exible or rigid pipe ø120 mm, the
choice of which is left to the installer.
• Insert the adapting ring 10 on the
hood body air outlet
• Fix the pipe in position using suffi cient
pipe clamps (not supplied).
• Remove any activated charcoal fi l-
ters.
RECIRCULATION VERSION AIR
OUTLET
• Cut a hole ø 125 mm in any shelf that may
be positioned over the hood.
• Connect the fl ange to the outlet on the
shelf over the hood using a fl exible or rigid
pipe ø120 mm.
• Fix the pipe in position using suffi cient
pipe clamps (not supplied).
• Fix the directional grille 8 on the recirculation air outlet using the 2 screws 12e (2,9
x 9,5) provided.
• Ensure that the activated charcoal fi lters
have been inserted.
ø 125
EN
10
12e
8
125125
9
ELECTRICAL CONNECTION
• Connect the hood to the mains through a
two-pole switch having a contact gap of at
least 3 mm.
• When opening the sliding carriage for the
fi rst time after installing the hood, pull it out
briskly until it clicks.
Page 8
8 electrolux Use
USE
EN
L Light Switches the lighting system
on and off.
M Motor Switches the extractor motor
on and off.
V Speed Sets the operating speed of
the extractor:
1.Low speed, used for a continuous
and silent air change in the presence
of light cooking vapour.
2.Medium speed, suitable for most
operating conditions given the optimum treated air fl ow/noise level
ratio.
3.Maximum speed, used for elimi-
nating the highest cooking vapour
emission, including long periods.
L
0
1
M - V
0
1
2
3
Page 9
MAINTENANCE
Grease fi lters
CLEANING METAL CASSETTE GREASE
FILTERS
• The fi lters must be cleaned every 2
months, or more frequently in case of
particularly heavy use of the hood. Filters can be washed in a dishwasher.
• Pull out the sliding suction panel.
• Remove the fi lters one by one, after
having disconnected the relative fastening elements.
• Wash the fi lters, taking care not to bend
them. Let them get dry before refi tting
them. (The colour of the fi lter surface
may change throughout the time but
this has no infl uence to the fi lter effi -
ciency).
• When refi tting the fi lters, make sure that
the handle is visible on the outside.
• Close the sliding suction panel.
Charcoal fi lter (Recycling version)
REPLACING CHARCOAL FILTERS
• These fi lters are not washable and
cannot be regenerated, and must be
replaced approximately every four
months or more frequently by particularly heavy use.
• Pull out the sliding suction panel.
• Remove the grease fi lters.
• Remove the saturated carbon fi lter by
releasing the fi xing hooks
• Replace the grease fi lters.
• Close the sliding suction panel.
Maintenance electrolux 9
EN
Lighting
LIGHT REPLACEMENT
40 W incandescent light.
• Remove the metal grease fi lters.
• Unscrew the bulbs and replace them
with new ones having the same characteristics.
• Replace the metal grease fi lters.
Page 10