AEG EFC9543U User Manual

Instructions Manual
Bedienungsanleitung
EFC 9543
EN
Instructions Manual INDEX
RECOMMENDATIONS AND SUGGESTIONS......................................................................................................................4
CHARACTERISTICS..............................................................................................................................................................5
INSTALLATION ......................................................................................................................................................................7
USE.......................................................................................................................................................................................11
MAINTENANCE....................................................................................................................................................................13
2
2
DE
Bedienungsanleitung INHALTSVERZEICHNIS
EMPFEHLUNGEN UND HINWEISE....................................................................................................................................15
CHARAKTERISTIKEN..........................................................................................................................................................16
MONTAGE............................................................................................................................................................................18
BEDIENUNG.........................................................................................................................................................................22
WARTUNG............................................................................................................................................................................24
3
3
EN
RECOMMENDATIONS AND SUGGESTIONS
The Instructions for Use apply to several vers i ons of thi s appl ianc e. Ac cordingly, you may find des cri p-
tions of individual features that do not apply to your specific appliance.
INSTALLATION
• The manufacturer will not be held liable for any damages resulting from incorrect or improper installa­tion.
• The minimum safety distance between the cooker top and the extractor hood is 650 mm.
• Check that the mains voltage c orres p onds to that i ndi cated on the rati n g plate fi x ed to the ins ide of the hood.
• For Class I appliances, check that the domestic power supply guarantees adequate earthing.
Connect the extractor to the exhaust fl ue through a pi pe of minimum dia meter 120 mm. T he route of
the flue must be as short as possible.
• Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
• If the extractor is used in conj unction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guarante ed in the room in order to prevent the backflow of ex­haust gas. The kitchen must have an openi ng communicating directly with the open air i n order to guarantee the entry of clean air.
USE
• The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells.
• Never use the hood for purposes other than for which it has ben designed.
• Never leave high naked flames under the hood when it is in operation.
• Adjust the flame intensity to direct i t onto the bottom of the pan only, mak ing sure that it does not en­gulf the sides.
• Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
• Do not flambè under the range hood; risk of fire
• This appliance is not intended for use by persons (i ncluding children) with reduced phy sical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
MAINTENANCE
• Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
• Clean and/or replace the Filters after the specified time period.
• Clean the hood using a damp cloth and a neutral liquid detergent.
4
4
EN
CHARACTERISTICS
700
Dimensions
Max
Min 810
1050
70
650
350
150
290
36
650 min.
5
5
EN
Components
Ref. Q.ty Product Components 1 1 Hood Canopy complete with: Controls, Lights, Filters 2 1 Telescopic chimney made up of:
2.1 1 Upper chimney
2.2 1 Lower chimney
7.1 1 Telescopic frame complete with Suction fan,made up
of:
7.1a 1 Upper frame
7.1b 1 Lower frame
9 1 Reduction flange ø 150-120 mm 10 1 Flange ø 150 10a 1 Damper ø 150 15 1 Air Outlet Connector 24 1 Connection box 25 2 Hose clamps 26 2 Cable clamps 27 1 Finishing plug
Ref. Q.ty Installation Components 11 4 Wall plugs ø 10 12c 6 Screws 2.9 x 6.5 12e 3 Screws 2,9 x 9,5 12f 4 Screws M6 x 10 12g 4 Screws M6 x 80 12h 4 Screws 5,2 x 70 21 1 Boring template 22 4 Washers øi 6.4 23 4 Nuts M6
Q.ty Documentation 1 Instruction booklet
21
22
23
7.1a
12g
7.1
7.1b
12c
2.1
2
2.2
12c
1
12f
9
12c
11
12h
15
10
10a
25
26
27
12e
24
6
6
EN
INSTALLATION
Drilling the Ceiling/shelf and fixing the frame
DRILLING THE CEILING/SHELF
• Use a plumb line to mark the centre of the hob on the ceiling/support shelf.
• Place the drilling template 21 provided on the ceiling/support shelf, making sure that the
template is in the correct position by lining up the axes of the template with those of the hob.
• Mark the centres of the holes in the template.
• Drill the holes at the points marked:
• For concrete ceilings, drill for plugs appropriate to the screw size.
• For hollow brick ceilings with wall thickness of 20 mm: drill ø 10 mm(immediately insert
the Dowels 11 supplied).
• For wooden beam ceilings, drill according to the wood screws used.
• For wooden shelf, drill ø 7 mm.
• For the power supply cable feed, drill ø 10 mm.
• For the air outlet (Ducted Versio n), drill according to t he diameter of the external air ex­haust duct connection.
• Insert two screws of the following type, crossing them and leaving 4-5 mm from the ceiling:
• For concrete ceilings, use the appropriate plugs for the screw size (not provided).
• for Cavity ceiling with inner space, with wall thickness of approx. 20 mm, Screws 12h, supplied.
• For wooden beam ceilings, use 4 wood screws (not provided).
• For wooden shelf, use 4 screws 12g with washers 22 and nuts 23, provided.
7
7
EN
Fixing the frame
2
2
1
1
• Loosen the two scre ws fastening the lower chimney and re­move this from the lower frame.
• Loosen the two screws fastening the upper chimney and re­move this from the upper frame.
If you wish to adjust the height o f the frame, proceed as follows:
• Unfasten the eight metric screws joining the two columns, lo­cated at the sides of the frame.
• Adjust the frame to th e height required, then repl ace all the screws removed as above.
• Insert the upper chimney stack from above, and leave it run­ning free on the frame.
• Lift up the frame, fit the frame slots onto the screws up to the slot end positions.
• Tighten the two screws and fasten the other two screws pro­vided with the hood.
Before tightening the screws completely it is possible to adjust the frame by turning it. Make sure that the screws do not come out of their seats in the slotted holes.
• The frame mountings must be secure to withstand the weight of the hood and any stresses caused by the occasional side thrust applied to the device.
On completion, check that the base is stable, even if the frame
is subjected to bending.
• In all cases where the ceiling is not strong enough at the sus­pension point, the installer must provide strengthening using suitable plates and backing pieces anchored to the structurally sound parts.
8
8
EN
Connections
ø 120
25
9
10a
10a
ø 150
25
12f
12c
12c
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120mm, the choice of which is left to the installer.
To install a ø 150
• To install the dumper 10a.
• Fix the pipe in position using sufficient pipe clamps (not sup­plied).
To install a ø 120
• To install a ø 120 mm air exhaust connection, insert the re­ducer flange 9 on the dumper 10a.
• Fix the pipe in position using sufficient pipe clamps (not sup­plied).
• Remove any activated charcoal filters.
Recirculation version air outlet
• Fix the connection 15 to the frame using the 4 screws pro­vided.
• Fix the flan ge 10 to the lower opening of the connection 15.
• Connect the hood air outlet to the flange in the lower part of the junction using a rigid or flexible ø 150 tube (by installer’s choice).
15
10
Flue assembly - Mounting the hood body
• Position the upper chimney section and fix the upper part to the frame using the 2 screws 12c (2,9 x 6,5) provided.
• Similarly, position the lower chimney section and fix the lower part to the frame using the 2 screws 12c (2,9 x 6,5) pro­vided.
Before fixing the hood body to the frame:
• Remove the grease filters from the hood body.
• Remove any activated charcoal filters.
• From below, use the 4 screws 12f (M6 x 10)provided to fix the hood body to the frame.
9
9
Loading...
+ 19 hidden pages