AEG EFC938X, EFC938X-2, EFC938X-1 User Manual

User Manual
EFC 938
UK
Contents
Safety instructions.............................................................................................................. 41
Description of the appliance.............................................................................................. 42
Mounting of grease filters .....................................................................................................................................42
Exhausting version ................................................................................................................................................42
Recycling version ..................................................................................................................................................42
Special accessories ............................................................................................................ 43
Active carbon filter ................................................................................................................................................43
Installation ........................................................................................................................... 43
Placement ..............................................................................................................................................................43
Electrical connection .............................................................................................................................................43
Mounting of hood ..................................................................................................................................................44
Exhausting version ................................................................................................................................................45
Recirculating version.............................................................................................................................................45
For both versions: ..................................................................................................................................................45
Mounting of carbon filter (for recirculating version) ............................................................................................45
Using the hood.................................................................................................................... 4 6
Intensive speed b utton ...........................................................................................................................................46
Control devices for the grease filter and carbon filter ...........................................................................................46
Important to know .................................................................................................................................................46
Grease filter saturation led.....................................................................................................................................46
Carbon filter saturation led....................................................................................................................................47
Correct ventilation .................................................................................................................................................47
Maintenance ........................................................................................................................ 47
Grease filter ...........................................................................................................................................................47
Carbon filter...........................................................................................................................................................47
Changing the lighting elements.............................................................................................................................47
If the hood does not function ............................................................................................ 48
Service and spare parts...................................................................................................... 4 8
Technical data ..................................................................................................................... 48
Dimensions ..................................................................................................................... .......................................48
2
Congratulations to your ne w Cooker Hood
Thank you for your choice of an Electrolux product. We are convinced that you will have great use and pleasure from your new cooker hood.
Before you use the cooker hood we recommend that you read through the whole user manual giving a direct description of the cooker hood and its functions.
To avoid the risks, that are always present when you use a product driven by electricity, it is important that the cooker hood is installed correctly and that you read the safety instruc­tions carefully to avoid misuse and hazard.
Save the instruction manual and keep it available at use of the cooker hood
Safety instructions
At installation and service
The cooker hood is made for normal households
with normal cooking. If it is used for other purposes there is a risk of damage which is not covered by the warranty.
All eventual electric installation has to be
carried out by a qualified electrician. The installation of the hood should be made by a person with enough knowledge. Installation made otherwise could lead to loss of perform­ance and even injuries and /or damage on properties.
The hood cannot be connected to flues of other
appliances that run on energy sources other than electricity. Please, keep to the provisions of official direc­tives regarding the question of fumes discharge.
When the hood is used at the same time of other
appliances that run on energy sources other than electricity, provision must be made for an adequate supply of air.
When installed, the hood must be not less than
50 cm. above electric burners or 75 cm. above gas or mixed-fuel burners. (Fig. 3).
At use of cooker hood
No food must be cooked flambee underneath the
hood.
The use of an unprotected flame is dangerous
for the filters and could cause fires.
Never leave the deep-frying or frying pan over a
cooker/hob. The oil contained in the pan may spontaneously ignite through overheating.
Observe the filter change or cleaning intervals.
Failure to observe these intervals may cause the risk of fire through fat deposition.
Note! If a fire starts; Switch of the cooker hood and the heating zone; Cover the fire , Never use
water.
At disposal
Help to avoid damages even when the cooker
hood should be disposed. Disconnect the power plug and cut the power cord at hood inlet. Check with the authorities for information of how to proceed for disposal.
The power cord should be drawn so that there is
no risk of damage. Hazard!
3
Description of the appliance
1. Control panel
2. Operating light
3. Grease filters
Standard accessories included:
Screws for mounting
Template for wall mounting
No return valve (mounted on air outlet)
Mounting of grease filters
Attention! The grease filters are supplied not mounted and packed in order to avoid damages during transport of the hood.
Fit the pins of the filter on the slots of the grease
filter housing (a), then use the handles of the filter to lock them (b).
Dismount the filter the opposite way.
Pull the handles backwards (c) to loosen the
filter (d) (Fig. 1).
3
1
2
Function
The hood may be used as follows:
- Exhausting version
- Recycling version Attention! The Cooker hood is ready to be used for air recycling (carbon filter already mounted in place).
Exhausting version
The air is vented outdoors by a 150 mm duct which must be connected to connecting ring with no return valve on top of the motor package.
The hood cannot be connected to flues of other appliances that run
on energy sources other than electricity. Please, keep to the provisions of official directives regarding the question of fumes discharge.
Fig. 1
Recycling version
The air is filtered through a carbon filter and recirculated into the room through the top sides of the chimney (Fig. 2). This version is used when there is no exhaust duct for venting outdoors or when it is impossible to install one.
Fig. 2
4
Loading...
+ 8 hidden pages