AEG EFC6412X, EFC9412U, EFC6412U, EFC6404X, EFC9412X User Manual

...
Montage- und Gebrauchsanweisung , Installatie- en gebruiksaanwijzing, Notice dutilisation et dinstallation
EFC 9404 - 9412 - 9408
EFC 6404 - 6412
Operating and Installation Instructions, Instrucciones de montaje y manejo, Manual de Instruções
D
NL
F E P
UK
Contents
Safety warnings................................................................................................................................................... 3 9
For the installer ......................................................................................................................................................39
For the user ............................................................................................................................................................39
Description of the Appliance ............................................................................................................................ 40
Extractor version....................................................................................................................................................40
Recirculation Version .............................................................................................................................................40
Control Panel...................................................................................................................................................... 41
Correct ventilation ..................................................................................................................................................41
Maintenance and Care ...................................................................................................................................... 42
Cleaning the hood ..................................................................................................................................................42
Metal grease filter ..................................................................................................................................................42
Charcoal filter ........................................................................................................................................................43
Changing the light bulb........................................................................................................................................... 44
Something Not Working ................................................................................................................................... 45
Special accessories............................................................................................................................................ 45
UK
Service and Spare Parts .................................................................................................................................... 46
Guarantee Conditions ....................................................................................................................................... 47
Technical Specifications .................................................................................................................................... 48
Installation .......................................................................................................................................................... 48
Unpacking .............................................................................................................................................................. 48
Fitting ..................................................................................................................................................................... 48
Electrical connection .............................................................................................................................................. 48
Mounting accessories included ..............................................................................................................................49
Wall unit mounting..................................................................................................................................................49
Before installing or using this appliance please read this instruction book carefully paying particular attention to the safety warnings on the following page. If you have any queries regarding this appliance please contact Customer Care for advice. Please keep this instruction book for future reference and pass it on to any future owner of the appliance.
Safety warnings
For the installer
When used as an extractor unit, the hood must
be fitted with a 150mm diameter hose.
Attention: The hose is not supplied and must be purchased separately.
When installing the hood, make sure you
respect the following minimum distance from the top edge of the cooking hob/ring surfaces: electric hobs 500 mm gas hobs 650 mm
The hood can be installed above these heights but for optimum performance it should be installed at the distance quoted for the appropriate heat source.
The national Standard on fuel-burning systems
specifies a maximum depression of 0.04 mbar in such rooms.
The air outlet must not be connected to chimney
flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.
The air outlet installation must comply with the
regulations laid down by the relevant authorities.
When the unit is used in its extractor version, a
sufficiently large ventilation hole must be provided, with dimensions that are approxi­mately the same as the outlet hole.
National and regional building regulations
impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room.
Hoods can only be used safely with appliances
connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approxi­mately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood.
If you have any doubts, contact the relevant
controlling authority or building inspectors office.
Since the rule for rooms with fuel burning
appliances is outlet hole of the same size as the ventilation hole, a hole of 500-600 cm2, which is to say a larger hole, could reduce the perfor­mance of the extractor hood.
If the hood is used in its filtering function, it will
operate simply and safely in the above conditions without the need for any of the
aforementioned measures.
When the hood is used in its extractor function,
the following rules must be followed to obtain optimal operation:
 short and straight outlet hose  keep bends in outlet hose to a minimum  never install the hoses with an acute angle,
they must always follow a gentle curve.
 keep the hose as large as possible
(preferably the same diameter as the outlet hole).
Failure to observe these basic instructions will
drastically reduce the performance and increase the noise levels of the extractor hood.
For the user
The cooker hood is designed to extract
unpleasant odours from the kitchen, it will not extract steam.
Always cover lighted elements, to prevent
excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames.
Also, when frying, keep the deep frying pan on
the cooker top/cooker under careful control.
The hot oil in the frying pan might ignite due to
overheating.
The risk of self-ignition increases when the oil
being used is dirty.
It is extremely important to note that
overheating can cause a fire.
Never carry out any flambé cooking under
the hood.
Always disconnect the unit from the power
supply before carrying out any work on the hood, including replacing the light bulb
(take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker).
It is very important to clean the hood and
replace the filter at the recommended intervals. Failure to do so could cause grease deposits to build up, resulting in a fire hazard.
The appliance is not intended for use by young
children or infirm persons without supervision.
Young children should be supervised to ensure
that they do not play with the appliance.
WARNING - Ensure that the appliance is
switched off before replacing the lamp to avoid the possibility of electric shock.
Description of the Appliance
The hood is supplied as an extractor unit and
can also be used with a filtering function by fitting one charcoal filter.
You will need an original charcoal filter for this
function (Available from your local Service Force Centre).
Only for EFC 9408 Attention! This model is already fitted with
charcoal filter.
Extractor version
In this version fumes are extracted to the
outside via a hose connected to the coupling ring A. Fig. 1.
In order to obtain the best performance the hose
should have a diameter equal to the outlet hole.
Fig. 1
Filter Version
The air is filtered through an charcoal filter and
returned to the kitchen through the top grill of the outlet pipe.
You will need an original charcoal filter for the
filtering function. (See Special Accessories).
Fix the deflector using 2 screws Ø 2,9x13 mm.
Fig. 2.
Optionally, the position of the chimney elements
can be changed. When using the hood in the filter version the chimney must be fixed at the top, with the air outlet grill at the side.
Fig. 2
Control Panel
Best results are obtained by using a low speed for normal conditions and a high speed when odours are more
concentrated. Turn the hood on a few minutes before you start cooking, you will then get an under pressure in the kitchen. The hood should be left on after cooking for about 15 minutes or until all the odours have disappeared. The control switches are located on the units front panel:
EFC 9404-6404-9408
A - Mains switch, OFF.
B - Start and choice of motor speed 1-2-3-1-2.........
C - Indicates speed 1 (LED). D - Indicates speed 2 (LED) E - Indicates speed 3 (LED) F - Indicates Intensive speed (LED). G - Intensive speed on/off. The Intensive speed runs for 5 minutes:
If the hood is on when the Intensive speed is activated, the hood reverts to previous speed after 5 minutes. If the hood is off when the Intensive speed is activated, the hood will be turned off after 5 minutes. To interrupt the Intensive speed, press button A or B.
H - Light ON/OFF
Should the hood or the controls fail to operate: disconnect the power supply for at least 5 seconds, then turn the hood back on again.
EFC 9412 - EFC 6412
the light switch switches the hood lamp on and off  the motor switch switches the motor on and off, enabling you to select one of the three different speeds.
O 1 2 3
light switch
Correct ventilation
If the cooker hood is to work correctly there must be an under pressure in the kitchen. It is important to keep the kitchen windows closed and have a window in an adjacent room open.
motor switch
Loading...
+ 10 hidden pages