Montage- und Gebrauchsanweisung
Installatie- en gebruiksaanwijzing
Manuel de montage et d’utilisation
Operating and Installation Instructions
Contents
Safety warnings57
for user
for kitchen unit installer
Introduction59
Extractor version
Filter version
Hood operation60
Maintenance and care61
Metal grease filter
Open the metal grease filter
Carbon filter62
Changing the light bulb63
Cleaning64
Special accessories
Technical assistance service
Guarantee conditions65
Service
Technic Details67
Installation68
Electrical connection
Safety warnings for the electrician
Wall unit mounting69
56
Safety warnings
for user
• Always cover lighted elements, to prevent excess heat from
damaging the appliance. In the case of oil, gas and coal fired
cookers it is essential to avoid open flames.
• Also, when frying, keep the deep frying pan on the cooker top/
cooker under careful control.
• The hot oil in the frying pan might ignite due to overheating.
• The risk of self-ignition increases when the oil being used is dirty.
• It is extremely important to note that overheating can cause a fire.
• Never carry out any flambé cooking under the hood.
• Always disconnect the unit from the power supply before
carrying out any work on the hood, including replacing the
light bulb (take the cartridge fuse out of the fuse holder or switch
off the automatic circuit breaker).
• It is very important to clean the hood and replace the filter at
the recommended intervals. Failure to do so could cause
grease deposits to build up, causing a fire hazard.
for kitchen unit installer
• When used as an extractor unit, the hood must be fitted with a
150mm diameter hose.
Falls ein Abluftrohr in Wand oder Dach mit einen Durchmesser von
125 mm schon besteht, kann der mitgelieferte Reduzierstutzen,
150/125 mm, verwendet werden. Zusammen mit dem
Reduzierstutzen kann der Ablaufschlauch 125 montiert werden.
• When installing the hood, make sure you respect the following
minimum distance from the top edge of the cooking hob/ring
surfaces:
electric cookers600 mm
gas cookers650 mm
coal and oil cookers700 mm min.
57
• The national decree on fuel-burning systems specifies a
maximum depression of 0.04 bar in such rooms.
• The air outlet must not be connected to chimney flues or
combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which
fuel-burning appliances are installed.
• It is advisable to apply for authorization from the relevant
controlling authority when connecting the outlet to an unused
chimney flue or combustion gas duct.
The air outlet installation must comply with the regulations
laid down by the relevant authorities.
• When the unit is used in its extractor version, a sufficiently
large ventilation hole must be provided, with dimensions that
are approximately the same as the outlet hole.
• National and regional building regulations impose a number
of restrictions on using hoods and fuel-burning appliances
connected to a chimney, such as coal or oil room-heaters
and gas fires, in the same room.
• Hoods can only be used safely with appliances connected to a
chimney if the room and/or flat (air/environment combination) is
ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression
being created during operation of the hood.
• If you have any doubts, contact the relevant controlling authority or
building inspector’s office.
• Since the rule for rooms with fuel burning appliances is “outlet hole
of the same size as the ventilation hole”, a hole of 500-600 cm2,
which is to say a larger hole, could reduce the performance of the
extractor hood.
• If the hood is used in its filtering function, it will operate simply and
safely in the above conditions without the need for any of the
aforementioned measures.
• When the hood is used in its extractor function, the following rules
must be followed to obtain optimal operation:
— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute angle, they must
always follow a gentle curve only
— keep the hose as large as possible (150 mm Ø min.).
• Failure to observe these basic rules will drastically reduce the
performance and increase the noise levels of the extractor hood.
58
Introduction
Extractor version
• The hood is supplied in the extractor version, but it can also be used
in the filter version by inserting an activated charcoal filter (special
accessory).
• To do this, use an original AEG activated charcoal filter (see Special
accessories).
• The air is discharged to the outside through a pipe, which must be
fitted to connection flange A. Fig. 1.
• For the extractor version this pipe must have a diameter of 150 mm.
Should there already be a pipe of diameter 125 mm that ducts to
the outside through the walls or roof, it is possible to use the 150/
125 mm reduction flange provided. In this case the hood will be
slightly more noisy.
Fig. 1
Filter version
• The air is filtered through an activated charcoal filter and returned to
the kitchen through the top grill of the outlet pipe.
• When the hood is used in the filter version it must be fitted with an
original AEG KF20 activated charcoal filter (see Special accessories).
• Fix the deflector using two screws Ø 3.5x6.5 mm. Fig. 2.
• Optionally, the position of the chimney elements can be changed.
When using the hood in the filter version the chimney must be fixed
at the top, with the air outlet grill at the side.
59
Fig. 2
Hood Operation
• Best results are obtained by using a low speed for normal
conditions and high speed when odours are more concentrated.
Turn the hood on a few minutes before you start cooking then you
will get an underpressure in the kitchen. It should be left on after
cooking for about 15 minutes or until all odours have disappeared.
The control switches are located on the unit’s front panel:
A:Main switch, hood on/off.
B:Start and choice of motor speed 1-2-3-1-2.........
- If the hood is on when the Intensive speed is activated, the
hood revert to previous speed after 5 minutes.
- If the hood is off when the Intensive speed is activated, the hood
will automaticly be turned off after 5 minutes.
To interrupt the Intensive speed, press button A or B.
H:Light off.
I:Light on.
ABCDEFGH I
Should the hood or the controls fail to operate: disconnect the power supply
for at least 5 seconds, then turn the hood back on again.