1-1 About This Manual .............................................................................................................................. 3
1-2 Features ............................................................................................................................................. 3
3-1 Before Use.......................................................................................................................................... 8
3-2 During Use.......................................................................................................................................... 9
3-3 After Use........................................................................................................................................... 10
3-4 Power Supply ................................................................................................................................... 10
3-5 Display Symbols and Key Operation.................................................................................................11
4. WEIGHING UNITS ........................................................................................................................12
4-2 Storing Units ..................................................................................................................................... 14
Dust-tight and protected against water jets (complying with IP65), suitable to weigh powdery or
liquid material. A waterproof RS-232C cable (AX-KO2737-500) is available as an option.
Compact general-purpose balance, can be installed almost anywhere.
Casing construction, strong protection against dust and water.
Stabilization time of one second. When FAST is selected for the response rate, a stabilization
time of one second, to read a displayed value after a sample is placed on the pan, has been
achieved.
Multiple weighing units with most of the common units used around the world.
Standard RS-232C serial interface to communicate with a computer and to output the Good
Laboratory Practice (GLP) data
Statistical calculation mode to statistically calculate the weight data, and display or output the
sum, maximum, minimum, range (maximum-minimum), average, standard deviation and
coefficient of variation.
Comparator Indicators, displaying the comparison results.
Hold Function, provided for weighing a moving object such as an animal.
Breeze break, provided for the FX-120i WP /200i WP /300i WP, for more accurate weighing.
Underhook, provided for suspended weighing.
As options, the USB interface (FXi-02), the Ethernet interface (Fxi-08) and the built-in battery unit
(Fxi-09) are available. When any one of these is used, the balance does not comply with IP65.
3
1-3 Compliance
Compliancewith FCC Rules
Please note that this device generates, uses and can radiate radio frequency energy. This
device has been tested and has been found to comply with the limits of a Class A computing
device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide
reasonable protection against interference when this device is operated in a commercial
environment. If this unit is operated in a residential area, it may cause some interference and
under these circumstances the user would be required to take, at his own expense, whatever
measures are necessary to eliminate the interference.
(FCC = Federal Communications Commission in the U.S.A.)
Compliance with EMC Directives
This device features radio interference suppression and safety regulation in compliance
with the following Council Directives
Council directive 89/336/EEC EN61326 EMC directive
Council directive 73/23/EEC EN60950 Safety of Information Technology Equipment
The CE mark is an official mandatory European marking.
Please note that any electronic product must comply with local laws and regulations when sold or
used anywhere outside Europe.
4
5
2. UNPACKING THE BALANCE
2-1 Unpacking
The balance is a precision instrument. Unpack the balance carefully. Keep the packing
material to be used for transporting the balance in the future.
The packing contents depend on the balance model. See the illustrations to confirm that
everything is contained.
How to assemble the breeze break (Only for FX-120i WP/200i WP/300i WP)
Assemble the breeze break as shown below.
Follow the numbered sequence.
When attaching the pan
support, use much care not
to deform the diaphragm.
Waterproof
diaphragm
Display
Bubble spirit
Keys
level
4
2
1
3
Weighing pan
Main unit cover
Pan support
Pan boss
AC adapter jack
RS-232C
serial interface
Main unit
Grounding
AC adapter plug
terminal
Main unit rear side
Leveling foot
AC adapter
Note
Please confirm that the AC adapter type is correct
for your local voltage and receptacle type.
AC adapter
ID label
Terminal cover
To use as a dust and waterproof
balance, cover the RS-232C
interface connector, or connect the
waterproof RS-232C cable
(AX-KO0273-500).
6
The AC adapter plug is
protected against dust
and may be difficult to
insert. When inserting
the plug, turn the plug
while pushing on it.
2-2 Installing the Balance
Install the balance as follows:
1. Place the balance on a solid weighing table. Refer to “3. PRECAUTIONS” for installing the balance.
2. FX-120
Assemble the pan support, weighing pan and breeze break, on the balance as shown in the
illustration on page 6.
FX-1200
Assemble the pan support and weighing pan on the balance as shown in the illustration on page 6.
3. Adjust the leveling feet to level the balance. Confirm it using the bubble spirit level.
4. Confirm that the AC adapter type is correct for the local voltage and power receptacle type.
5. Connect the AC adapter to the balance. Warm up the balance for at least 30 minutes with
nothing on the weighing pan.
Note
The AC adapter plug is protected against dust and may be difficult to insert. When inserting
the plug, turn the plug while pushing on it.
i WP /200i WP /300i WP
i WP /2000i WP /3000i WP
7
3. PRECAUTIONS
To get the optimum performance from the balance and acquire accurate weight data, note the
following:
3-1 Before Use
The meaning of IP65 is "No ingress of dust. Projected
against water jets".
If a powerful water jet is used or the balance is immersed
in water, the ingress of water may cause damage to the
balance.
Confirm that "the plug is inserted firmly into the AC adapter
jack" and "the RS-232C interface connector is covered
using the terminal cover or the waterproof RS-232C cable
(AX-KO2737-500) is connected", when using as a dust and
waterproof balance.
When the balance is used without the terminal cover on
the RS-232C interface connector or a standard RS-232C
cable is used, the balance does not comply with IP65.
Install the balance in an environment where the
temperature and humidity are not excessive. The best
operating temperature is about 20°C / 68°F at about 50%
relative humidity.
Install the balance where it is not exposed to direct sunlight
and it is not affected by heaters or air conditioners.
Install the balance where it is free of dust.
Install the balance away from equipment which produces
magnetic fields.
Install the balance in a stable place avoiding vibration and
shock. Corners of rooms on the first floor are best, as they
are less prone to vibration.
The weighing table should be solid and free from vibration,
drafts and as level as possible.
Level the balance by adjusting the leveling feet and
confirm it using the bubble spirit level.
Ensure a stable power source when using the AC adapter.
Plug in the AC adapter and warm up the balance for at
least 30 minutes.
Calibrate the balance before use or after having moved it
to another location.
Caution
Do not install the balance where flammable or corrosive gas is present.
8
3-2 During Use
The FX-i WP series balance has a casing with high sealing
performance due to its dust-tight and waterproof design.
Therefore, a very subtle change in the atmospheric
pressure in the installation site, for example, generated by
opening or closing the door, affects the weighing and may
yield an unstable weight value. Wait for the atmospheric
pressure to stabilize before weighing.
If the residue of a powdery or liquid material is left on the
waterproof diaphragm or the pan boss, it may cause
weighing errors. Clean them before weighing.
If the waterproof diaphragm is deformed due to
overloading, it may cause weighing errors. Remove the
load and wait for the waterproof diaphragm to restore to
the original shape before continuing with weighing.
Discharge static electricity from the material to be weighed
(hereinafter referred to as the sample). When a sample
could have a static charge, the weight data is influenced.
Ground the balance and try the following:
Eliminate static electricity using the optional AD-1683 DC
static eliminator.
Try to keep the ambient humidity above 45%RH.
Use a metal shield case for a charged sample.
Wipe charged plastic samples with a moistened cloth.
This balance uses a strong magnet as part of the balance
assembly, so please use caution when weighing magnetic
materials such as iron. If there is a problem, use the
underhook on the bottom of the balance to suspend the
material away from the influence of the magnet.
Eliminate the temperature difference between a sample
and the environment. When a sample is warmer (cooler)
than the ambient temperature, the sample will be lighter
(heavier) than the true weight. This error is due to a rising
(falling) draft around the sample.
Make each weighing gently and quickly to avoid errors
caused by the evaporation of moisture from the sample or
the absorption of moisture by the sample.
Do not drop things upon the weighing pan, or place a
sample on the pan that is beyond the balance weighing
capacity. Place a sample in the center of the weighing pan.
Do not use a sharp instrument such as a pencil to press
the keys. Use your finger only.
9
Press the RE-ZERO key before each weighing to eliminate possible errors.
Calibrate the balance periodically so as to eliminate possible errors.
Take into consideration the affect of air buoyancy on a sample when more accuracy is
required.
Prevent foreign materials, such as powder, liquid and metal, from invading the area around the
weighing pan.
The breeze break (FX-120i WP /200i WP/300i WP only) is provided as an accessory. An
anti-static treatment has been applied to the breeze break components, but they may be
charged with static electricity when they are unpacked or when the humidity is low. If the
weight value is unstable even when there are no drafts or the balance has a problem with
repeatability, remove the breeze break. Or wipe the clear plates with a moistened cloth, use
the optional AD-1683 DC static eliminator or apply an anti-static spray.
3-3 After Use
Do not allow the balance to be immersed in water. Even though the balance complies with IP
code, the balance will not withstand being completely immersed in water.
Avoid mechanical shock to the balance.
Do not disassemble the balance. Contact the local A&D dealer if the balance needs service or
repair.
Do not use organic solvents to clean the balance. Clean the balance with a lint free cloth that
is moistened with warm water and a mild detergent.
The edge of the weighing pan is sharp. Use much care when cleaning the pan.
3-4 Power Supply
When the AC adapter is connected, the balance is in the standby mode if the standby
indicator is on (refer to “3-5 Display Symbols and Key Operation”). This is a normal state and
does not harm the balance. For accurate weighing, warm up the balance for at least 30
minutes before use.
10
3-5 Display Symbols and Key Operation
Key operation
Key operation affects how the balance functions. The basic key operations are:
“Press and release the key immediately” or “Press the key”
= normal key operation during measurement
“Press and hold the key”
Display symbols
Each key, when pressed or when pressed and held, functions as follows:
Key When pressed When pressed and held
Turns the display on or off. The standby indicator is displayed when the display is
turned off. The weighing mode is enabled when the display is turned on.
This key is available anytime. Pressing the key during operation will interrupt the
operation and turn the display off.
In the weighing mode, turns the minimum
weighing value on or off.
In the counting or percent mode, enters
the sample storing mode.
Switches the weighing units stored in the
function table.
Refer to “4. WEIGHING UNITS”.
Cancels the operation when performing
settings.
Enters the function table mode.
Refer to “9. FUNCTION TABLE”.
Enters the response adjustment mode.
Enters the calibration mode.
Outputs the weight data to a printer or
personal computer using the RS-232C
serial interface, depending on the
function table settings.
Confirms the operation when performing
settings.
Sets the display to zero.
11
No function at the factory setting
By changing the function table:
Outputs “Title block” and “End block” for
GLP report.
4. WEIGHING UNITS
4-1 Units
With the FX-i WP series balance, the following weighing units and weighing modes are available:
A unit or mode can be selected and stored in the function table as described on page 14.
If a weighing mode (or unit of weight) has been turned off, that mode or unit will be missing in the
sequence. Tael has four varieties, one of which can be selected and installed at the factory.
To select a unit or mode for weighing, press the MODE key.For details about the units and modes,
see the table below:
Name (unit, mode) Display Function table
(Storing mode)
Gram g g 1 g
Conversion factor
1 g =
Counting mode pcs pcs
Percent mode % %
Ounce (Avoir) oz oz 28.349523125 g
Pound lb lb 453.59237 g
Pound/Ounce
Troy Ounce ozt ozt 31.1034768 g
Metric Carat ct ct 0.2 g
Momme 3.75 g
Pennyweight dwt dwt 1.55517384 g
Grain (UK) GN GN 0.06479891 g
Tael (HK general, Singapore) 37.7994 g
Tael (HK jewelry) 37.429 g
Tael (Taiwan) 37.5 g
Tael (China)
Tola (India) tol tol 11.6638038 g
Loz
tl tl
LO
1Lb=16 oz,
1 oz=28.349523125 g
31.25 g
Messghal 4.6875 g
Programmable-unit (Multi-unit) MLT MLT
12
The tables below indicate the weighing capacity and the minimum display for each unit, depending
Tael (HK general, Singapore) 32.275558.202084.6575 0.0005
Tael (HK jewelry) 32.595058.778085.4950 0.0005
Tael (Taiwan) 32.533058.667085.3330 0.0005
Tael (China) 39.040070.4000102.4000 0.0005
Tola (India) 104.597188.618274.353 0.001
Messghal 260.265469.335682.665 0.005
i WPFX-2000i WPFX-3000i WP
Minimum
display
13
4-2 Storing Units
The units or modes can be selected and stored in the function table. The sequence of displaying the
units or modes can be arranged in the function table so as to fit the frequency of use.
Select a unit or mode and arrange the sequence of display
as follows:
1 Press and hold the SAMPLE key until ba5fnc
the function table is displayed.
2 Press the SAMPLE key several times to display
1Unit .
3 Press the PRINT key to enter the unit selection mode.
4 Specify a unit or mode in the order to be displayed
using the following keys.
SAMPLE key To sequentially display the units.
RE-ZERO key To specify a unit or mode. The
stabilization indicator appears
when the displayed unit or mode
is specified.
5 Press the PRINT key to store the units or modes. The
balance displays end and then displays the next
menu of the function table.
of
6 Press the CAL key to exit the function table. Then the
balance returns to the weighing mode with the unit
specified first in step 4.
Notes
When the power is turned on, the scale displays the unit
specified first in step 4.
In the weighing mode, to select a unit or mode for weighing,
press the MODE key.
14
5. WEIGHING
5-1 Basic Operation (Gram Mode)
1 Place a container on the weighing pan, if necessary.
Press the RE-ZERO key to cancel the weight (tare). The
balance displays 0.00 g. (The decimal point position
depends on the balance model.)
2 Place a sample on the pan or in the container.
3 Wait for the stabilization indicator to be displayed. Read
the value.
While the stabilization indicator is on, pressing the PRINT
key will output the weight value, using the RS-232C serial
interface.
Note
Peripheral equipment, that is sold separately , such
as a printer or a personal computer is required.
4 Remove the sample and container from the pan.
Notes
To use other units, press the MODE key and select an
appropriate unit.
Press the SAMPLE key to turn on or off the minimum
weighing value.
When the ON:OFF key is pressed with a container placed
on the weighing pan, the balance displays 0.00 g and
weighing is started,
15
5-2 Counting Mode (PCS)
This is the mode to determine the number of objects in a sample based on the standard sample unit
mass. Unit mass means the mass of one sample. The smaller the variables in each sample unit
mass are, the more accurate the counting will be. The FX-i WP series balance is equipped with the
Automatic Counting Accuracy Improvement (ACAI) function to improve the counting accuracy.
Note
If the sample unit mass variable is too large, it may cause a counting error.
Selecting the counting mode
1 Press the MODE key to select 1pcs (counting mode).
Storing a sample unit mass
2 Press the SAMPLE key to enter the sample unit mass
storing mode.
Even in the storing mode, pressing the MODE key will
switch to the next mode.
3 To select the number of samples, press the SAMPLE key
several times. It may be set to 5, 10, 25, 50 or 100.
Note
A greater number of samples will yield more accurate
counting result.
4 Place a container on the weighing pan, if necessary.
Press the RE-ZERO key to cancel the weight (tare). The
number specified in step 3 appears.
e.g.: 25 0 is displayed if 25 is selected in step 3.
5 Place the number of samples specified on the pan. In this
example, 25 pieces.
6 Wait for the stabilization indicator to come on. Press the
PRINT key to calculate and store the unit mass. The
balance displays 25
count samples with this unit mass. (The sample unit mass
stored, even if the AC adapter is removed, is maintained
in non-volatile memory.)
To improve the accuracy of the unit mass, proceed to
step 8.
Notes
If the balance judges that the mass of the samples is too
light and is not adequate to be used as the unit mass, it
displays lo . In that case, store the mass by some quantity.
For example, when the model with the minimum weighing
value of 0.01 g is used and 10 pieces of samples weigh 0.05
g. Store 100 pieces of samples as 10 and multiply the
weighing result by 10.
pcs
(counting mode) and is set to
16
If the balance judges that the mass of the samples is too light to aquire accurate weighing, it
displays an error requiring the addition of more samples to the specified number. In the
PCS
example above, 150-
PRINT key. When the unit mass is stored correctly, the balance proceeds to the counting
mode.
appears, requiring 25 more samples. Add 25 samples and press the
Counting operation
7 Place the samples to be counted on the pan.
While the stabilization indicator is on, pressing the PRINT
key will output the weight value, using the RS-232C serial
interface.
Note
Peripheral equipment, that is sold separately , such
as a printer or a personal computer is required.
Counting mode using the ACAI function
The ACAI is a function that improves the accuracy of the unit
mass automatically by increasing the number of samples
and averaging the unit mass variable to minimize the
weighing error, as the counting process proceeds.
8 If a few more samples are added, the processing indicator turns on. To prevent an error, add
three or more. The processing indicator does not turn on if overloaded. Try to add the same
number of samples as displayed.
9 The balance re-calculates the unit mass while the processing indicator is blinking. Do not
touch the balance or samples on the pan until the processing indicator turns off.
10 Counting accuracy is improved when the processing indicator turns off.
Each time the above operation is performed, a more accurate unit mass will be obtained.
There is no definite upper limit of ACAI range for the number of samples exceeding 100. Try
to add the same number of samples as displayed.
11 Remove all the samples used in ACAI and proceed with the counting operation using the
improved unit mass.
17
5-3 Percent Mode (%)
This is the mode to display the weight value in percentage compared to a 100% reference mass and
is used for target weighing or checking the sample variable.
Selecting the percent mode
1 Press the MODE key to select % (percent mode).
Storing the 100% reference mass
2 Press the SAMPLE key to enter the 100% reference
mass storing mode.
Even in the storing mode, pressing the MODE key will
switch to the next mode.
3 Place a container on the weighing pan, if necessary.
Press the RE-ZERO key to cancel the weight (tare). The
balance displays 100 0 % .
4 Place the sample to be set as the 100% reference mass
on the pan or in the container.
5 Press the PRINT key to store the reference mass. The
balance displays 100.00 % . (The decimal point position
depends on the reference value. The reference mass
stored, even if the AC adapter is removed, is maintained
in non-volatile memory.)
Note
If the balance judges that the mass of the sample is too
light to be used as a reference, it displays lo . Do not use
the sample.
6 Remove the sample.
Reading the percentage
7 Place a sample to be compared to the reference mass on
the pan. The displayed percentage is based on the 100%
reference mass.
While the stabilization indicator is on, pressing the PRINT
key will output the weight value, using the RS-232C serial
interface.
Note
Peripheral equipment, that is sold separately , such
as a printer or a personal computer is required.
18
5-4 Statistical Calculation Mode
The statistical calculation mode statistically calculates the weight data, and displays or outputs the
results. To use the statistical calculation mode, set the "Application function (apf)" parameter of
“Application (ap fnc)” in the function table to “2”, as described below.
Statistical items available are number of data, sum, maximum, minimum, range
(maximum-minimum), average, standard deviation and coefficient of variation. What statistical items
to output can be selected from the three modes in the function table.
The wrong data input can be canceled by the key operation, if immediately after the input.
Turning the balance off will delete the statistical data.
The standard deviation and coefficient of variation are obtained by the equation below:
Standard deviation=
Standard deviation
Coefficient of variation (CV)=
where Xi is the i-th weight data,
N is number of data.
x 100 (%)
Average
5-4-1 Getting Started
Switching to the Statistical Function Mode (Changing The Function Table)
1 Press and hold the SAMPLE key until ba5fnc of
the function table is displayed, then release the key.
2 Press the SAMPLE key several times to display
1ap fnc .
3 Press the PRINT key to display apf 0 .
4 Press the RE-ZERO key to display apf 2 .
To select statistical items to output, go to step 5.
To store the statistical function mode setting, go to
step 7.
To disable the statistical calculation mode, press the
RE-ZERO key to select apf 0 .
19
Selecting the statistical items to output
5 Press the SAMPLE key to display 5taf 0 .
6 Press the RE-ZERO key to select the output items.
In the example, 5taf 1 is selected to output the
number of data, sum, maximum, minimum, range
(maximum-minimum) and average.
Parameter Description
0
1
2
7 Press the PRINT key to store the setting.
Note
The statistical calculation mode will be enabled using the
ON:OFF key or when the power is turned on.
8 Press the CAL key to return to the weighing mode.
Number of data, sum
Number of data, sum
Maximum, minimum, range (maximum – minimum), average
Number of data, sum
Maximum, minimum, range (maximum – minimum), average,
Standard deviation, coefficient of variation
Selecting the unit
9 Press the MODE key to select the unit to be used for
the statistical calculation mode.
Notes
Selecting the unit using the MODE key is not available after the
data is entered. In this case, clear the data as described on
page 23 and select the unit using the MODE key.
When the unit used for the statistical calculation mode is to be enabled upon power-on,
select the unit in “Unit (Unit)” of the function table beforehand.
20
5-4-2 Using The Statistical Calculation Mode
Entering data for statistical calculation
Use the following keys to operate the statistical calculation mode.
MODE key
SAMPLE key .......... Turns the minimum display on or off, in the weighing mode.
RE-ZERO key
PRINT key .............. Outputs the data number and the weight data and includes the weight data
CAL key .............. Returns to the weighing mode.
1 Press the RE-ZERO key to set the display to zero.
..............
........
2 Place the sample on the weighing pan and wait for
the stabilization indicator to turn on.
3 Press the PRINT key to add the data displayed to
statistical calculation. The number of data on the upper
left of the display increases by 1.
4 Repeat steps 1 to 3 for each weighing.
When the data is entered, moves between the displaying items (weighing
mode, statistical results and data operation) each time the key is pressed.
When no data has been entered, selects the unit.
Sets the display to zero in the weighing mode.
to statistical calculation in the weighing mode. (Output is not in the data
format specified in the function table because of the data number added.)
Outputs the statistical results while the statistical results are displayed.
(Output is not in the data format specified in the function table.)
21
Loading...
+ 51 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.