A. Physical Camera Description ............................................................................................................ 3
B. Installation ......................................................................................................................................... 5
C. Search and Modify IP ....................................................................................................................... 8
D. Preview via Web Browser............................................................................................................... 11
Alarm Deployment Time ............................................................................................................... 19
User Management .......................................................................................................................... 20
Add User ............................................................................................................................................. 20
Modify User ........................................................................................................................................ 20
F. Adding Camera to Monitor Station ................................................................................................. 21
4/10/2012 Page 2
Page 3
Advidia A-45 Bullet Camera
Serial NO.
Description
1
10M/100M self-adaptive Ethernet interface
2
Power supply
3
IN, G: Alarm input interface
1A, 1B: Alarm output interface
4
D+, D-: RS-485 interface
5
AUDIO IN, G: Audio input interface
AUDIO OUT, G: Audio output interface
A. Physical Camera Description
Note: There are two types of these cameras’ interface as shown in figure 1.1 and figure 1.2.
Please choose the right figure as your camera’s reference.
Figure 1.1
Figure 1.2
4/10/2012 Page 3
Page 4
Advidia A-45 Bullet Camera
Figure 1.3
4/10/2012 Page 4
Page 5
Advidia A-45 Bullet Camera
B. Installation
Please check if all the items on the package list have been included with your camera.
Read the following contents carefully before the installation.
Make sure that all the related equipment is power-off during the installation.
Check the power supply to prevent any damage caused by mismatching problems.
Do not place the camera in extremely hot or damp environment. To avoid heat
accumulation, good ventilation is required for a proper operating environment.
If the product does not operate properly, please contact your dealer or the nearest
service center. Never attempt to disassemble the camera yourself. Users are
responsible for any problem caused by modification or repairing without authorization.
Bullet camera can be fixed in both wall and ceiling, customers can choose different ways to
install the camera according to their specific needs. The following section introduces the wall
mounting, and the ceiling mounting methods:
Step 1: Fix the camera wire hidden box to the wall.
Figure 2.1 Fix camera wire hidden box
If it is cement wall, you need to fix the expand bolt (note: the mounting hole of the expand bolt
should align with the wire hidden box) before fixing wire hidden box as shown in Figure 2.1. If
the wall surface is wooden, you can use the self-tapping screw to fix the wire hidden box
directly. Please note that the wall on which the camera is fixed should be able to bear at least
three times the weight of the bracket and the camera.
4/10/2012 Page 5
Page 6
Advidia A-45 Bullet Camera
Step 2: Use screws to fix the mounting bracket with camera main body to wire hidden
box as shown in Figure 2.2.
Figure 2.2 Fix the camera
Step 3: Adjust the camera to the desired monitoring location and finally tighten the nuts
on bracket to fix the camera.
Step 4: Twist-off front cover from the camera, and then adjust the lens as shown in Figure 2.4
and Figure 2.5.
4/10/2012 Page 6
Figure 2.3 Adjust monitoring location
Page 7
Advidia A-45 Bullet Camera
Figure 2.4
Figure 2.5Adjust lens
Step 5: fix the lens and front cover as shown in Figure 2.6.
Figure 2.6
4/10/2012 Page 7
Page 8
Advidia A-45 Bullet Camera
1. Install the SADP software, and then run the
“sadpdlg.exe”.
C. Search and Modify IP
SADP (Search Active Devices Protocol) software can automatically search the IP address of
network cameras in the same local area network (LAN) with connection diagram as following:
Figure 3.1
The operation of searching and modifying IP address is described as following:
Figure 3.2
4/10/2012 Page 8
Page 9
Advidia A-45 Bullet Camera
2. Search IP address.
Figure 3.3
4/10/2012 Page 9
Page 10
Advidia A-45 Bullet Camera
3. Modify IP address.
4/10/2012 Page 10
Page 11
Advidia A-45 Bullet Camera
D. Preview via Web Browser
Note: The default IP of network cameras is ‘192.0.0.64’ with ‘admin’ as the
administrator, ‘12345’ as the password, and ‘8000’ as the default port.
For monitoring camera images, a computer running the Microsoft Windows Operating System
and Internet Explorer (Version 6.0 or later) are required. In this manual, we use Windows XP
and IE 6.0 for example.
Figure 4.1
1. Open the IE browser, set the security level to [Medium] in
[Tools/InternetOptions/Security/Custom Level…]
4/10/2012 Page 11
Page 12
Advidia A-45 Bullet Camera
Figure 4.2
2. Input the IP address of the camera and press [Enter], and then click the dialog box that pops
up.
3. Click [Run] to install the ActiveX control.
4/10/2012 Page 12
Figure 4.3
Page 13
Advidia A-45 Bullet Camera
Figure 4.4
4. Input “Username” (Default: admin), “Password” (Default: 12345) and “Port” (Default: 8000)
of the camera, then click [Login]
5. View the image
4/10/2012 Page 13
Figure 4.5
Page 14
Advidia A-45 Bullet Camera
E. Web Interface Configuration
Channel ParametersDisplaySetting
According to different
requirements, enable the display
of Date&Time and Week by
clicking the checkbox.
Different date formats can be
selected.
There are two Time format: 24
hour and 12 hour.
The OSD Status can be set to
transparent & flickering,
transparent & un-flickering, nontransparent & flickering, or nontransparent & un-flickering.
4/10/2012 Page 14
Page 15
Advidia A-45 Bullet Camera
Parameter
Description
Channel Name
Input the channel name for your need
Encode Parameters
Main stream or Sub stream optional
Stream Type
Video&Audio or Video optional
Resolution
Select the resolution for your need
Image Quality
Highest, Higher, Medium, Low, Lower or Lowest optional
Bitrate Type
Constant bitrate or Variable bitrate optional
Max. Bitrate
Select or customize a bitrate according to the resolution
Frame Rate
Select the frame rate for your need
Multicast Address
Set the multicast address, with the default multicast of
0.0.0.0
RTSP Port
Set the RTSP port, with the default RTSP port of 554
Channel ParametersVideo Settings
4/10/2012 Page 15
Page 16
Advidia A-45 Bullet Camera
Video Encode Type
Select the video encode type for your need
Channel ParametersMotion
Detection Setting
Select the checkbox of Enable motion detection to enable this function.
Zone Settings:Click Start draw
button to draw motion detection zone
by clicking and dragging the mouse
in the live video image.
User is allowed to draw multiple
motion detection zones in the same
picture. When all zones have been
set, click Stop draw to finish drawing.
Sensitivity:The sensitivity level can be set to 0, 1, 2, 3, 4 and 5. When it is set to 0, the sensitivity is
disabled.
Linkage:The Linkage method can be selected to either Email link, Trigger recording or Trigger alarm
output.
Click "Save" button to save the
modified parameters.
Channel ParametersText
Overlay Setting
Input the characters in the Text Information box and define the OSD
location in the image by setting the
XPosition and YPosition, and then
select the checkbox of OSD Text.
After clicking Save to finish the
settings, the defined title will be
displayed on the image.
Note: The values of XPosition and
YPositon are relative to the upper left corner origin of the image.
4/10/2012 Page 16
Page 17
Advidia A-45 Bullet Camera
Channel ParametersFront Para Config
In this page, user can adjust the
parameters like brightness, contrast,
saturation, sharpness, etc.
Shutter: User can set the shutter time
according to the different camera
models.
IrisMode:There are two modes:
IrisFirst and manual optional.
Power Mode:There are two modes:
50Hz and 60Hz optional.
Network ParametersNetwork Setting
Set the NIC Type, IP Address, Subnet
Mask, Gateway and DNS Server of the
network camera.
Click "Save" button to save the
modified parameters.
Note: Please reboot the network camera
to validate the modified parameters.
4/10/2012 Page 17
Page 18
Advidia A-45 Bullet Camera
Network ParametersNTP Setting
Click the checkbox of Enable NTP
to enable this function. Input the
Server Address and Port of NTP.
If the public network is applied,
please input the NTP Server Address with provision of time
sync service, e.g., 210.72.145.44.
In the private network is applied,
the NTP software can be used to
establish NTP server to achieve
time synchronization.
Click "Save" button to save the
modified parameters.
Note: Please reboot the network camera to validate the modified parameters.
Network ParametersE-mail Setting
Through E-mail settings, the alarm
message can be sent to the
designated E-mail address when
alarm event occurs.
Input the SMTP server, SMTP port,
user name, password, E-mail sender
and receiver.
Click "Save" button to save the
modified parameters.
Note: Please reboot the network
camera to validate the modified
parameters.
4/10/2012 Page 18
Page 19
Advidia A-45 Bullet Camera
Alarm ParametersAlarm Input Setting
Set the type of Relay Status to NC or
NO.
Note: Please reboot the network
camera to validate the modified
parameters.
The Linkage can be selected to E-mail
link, Trigger alarm output or Trigger
recording.
Click "Save" button to save the
modified parameters.
Alarm ParametersAlarm Output Setting
The Output Delay refers to the length of
time that the relay remains in effect
after alarm occurs. The output delay
time can be set to 5sec, 10sec, 30sec,
1min, 2min, 5min, 10min or Manual
(manually disable).
Click "Save" button to save the
modified parameters.
Alarm Deployment Time
The Deployment time can be set to
several days a week or to all week,
with only four period configurable for
each day.
Note: The alarm deployment time
setting is valid only when the camera
has already been configured with the
motion detection, alarm input and
alarm output functions.
Click "Save" button to save the
modified parameters.
4/10/2012 Page 19
Page 20
Advidia A-45 Bullet Camera
User Management
When the current login user is admin, it is allowed to create other users. Up to 15 users can be
created.
Add User
Click Add to enter the
settings interface as shown
here.
Input the user name,
password, IP address, MAC
address, and then select user
type. Finally, click OK to
finish the user addition.
Modify User
Click Modify to enter the
settings interface as shown
here.
It is allowed to modify the user
name, password, IP address,
MAC address, and then select
user type. Finally, click OK to
finish the user modification.
Note: Only the password of the user admin can be modified.
4/10/2012 Page 20
Page 21
Advidia A-45 Bullet Camera
F. Adding Camera to Monitor Station
Using Auto discovery, enter the default credentials described above and click Start.
Using Manual add on, choose to add a camera and select the following from the dropdown:
4/10/2012 Page 21
Page 22
Advidia A-45 Bullet Camera
4/10/2012 Page 22
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.