The documentation and the software included with this product are copyrighted 2019
by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right
to make improvements in the products described in this manual at any time without
notice. No part of this manual may be reproduced, copied, translated or transmitted
in any form or by any means without the prior written permissio n of Advantech Co.,
Ltd. Information provided in this manual is intended to be accurate and reliable. However, Advantech Co., Ltd. assumes no responsibility for its use, nor for any infringements of the rights of third parties, which may result from its use.
Acknowledgements
Windows is registered trademarks of Microsoft.
All other product names or trademarks are properties of their respective owners.
Product Warranty (2 years)
Advantech warrants to you, the original purchaser, that each of its products will be
free from defects in materials and workmanship for two years from the date of purchase.
This warranty does not apply to any products which have been repaired or altered by
persons other than repair personnel authorized by Advantech, or which have been
subject to misuse, abuse, accident or improper installation. Advantech assumes no
liability under the terms of this warranty as a consequence of such events.
Because of Advantech’s high quality-control standards and rigorous testing, most of
our customers never need to use our repair service. If an Advantech product is defective, it will be repaired or replaced at no charge during the warranty period. For outof-warranty repairs, you will be billed accor ding to the co st of replacement materials,
service time and freight. Please consult your dealer for more details.
If you think you have a defective product, follow these steps:
1. Collect all the information about the problem encountered. (For example, CPU
speed, Advantech products used, other hardware and software used, etc.) Note
anything abnormal and list any onscreen messages you get when the problem
occurs.
2. Callyour dealer and describe the problem. Please have your manual, product,
and any helpful information readily available.
3. If your product is diagnosed as defective, obtain an RMA (return merchandize
authorization) number from your dealer. This allows us to process your return
more quickly.
4. Carefully pack the defective product, a
Order Card and a photocopy proof of purchase date (such as your sales receipt)
in a shippable container. A product returned without proof of the purchase date
is not eligible for warranty service.
5. Write the RMA number visibly on the outside of the package and ship it prepaid
to your dealer.
Part No. Edition 1
fully-completed
Repair and Replacement
Jan 2019
TREK-120 User Manual
Declaration of Conformity
CE
his product has passed the CE test for environmental specifications. Test conditions
T
for passing included the equipment being operated within an industrial enclosure. In
order to protect the product from being damaged by ESD (Electrostatic Discharge)
and EMI leakage, we strongly recommend the use of CE-compliant industrial enclosure products.
FCC Class B
e: This equipment has been tested and found to comply with the limits for a Class
Not
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful interference to radio c ommunications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or televisio n reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
„
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
A
ny changes or modifications not expressly approved by the party
responsible for compliance could void the authority to operate
equipment.
his device complies with Part 15 FCC Rules.
T
Operation is subject to the following two conditions.
(1) This device may not cause harmful interference , and
(2) The device must accept any interference received, includi
i
nterference may cause undesired operation.
FCC Caution :
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate this equipment.
FCC RF Radiation Exposure Statement :
This device meets
This device is designed and manufactured not to exceed the emission limits for
exposure to radio frequency (RF) energy set by the Federal Communications
Commission of the U.S. Government.
the government`s requirements for exposure to radio waves.
ng
TREK-120 User Manual
Changes or modifications not expressly approved by the party responsible for
compliance could void the user`s authority to operate the equipment.
.
Technical Support and Assistance
1.Visit the Advantech web site at
he latest information about the product.
t
2.Contact your distributor, sales representative, or Advantech's customer service
center for technical support if you need additional assistance. Please have th
f
ollowing information ready before you call:
– Product name and serial number
– Description of your peripheral attachments
– Description of your software (operating system, version, application software
et
c.)
– A complete description of the problem
– The exact wording of any error messages
http://support.advantech.com
where you can find
e
,
TREK-120 User Manual
Description
Q`ty
TREK-120ANR
1
USB Cable
1
Warnings, Cautions and Notes
Warning! Warnings indicate conditions, which if not observed, can cause personal
injury!
Caution! Cautions are included to help you avoid damaging hardware or losing
data. e.g.
There is a danger of a new battery exploding if it is incorrectly installed.
Do not attempt to recharge, force open, or heat the battery. Replace the
battery only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer's
Note! Notes provide optional additional information.
instructions.
Document Feedback
To assist us in making improvements to this manual, we would welcome comments
and constructive criticism. Please send all such - in writing to: support@advantech.com
Packing List
Before setting up the system, check that the items listed below are included and in
good condition. If any item does not accord with the table, please contact your dealer
immediately.
Ordering Information
Part Number
Description
TREK-120-ANR000A00
Cold Chain NFC reader
Safety Instructions
1. Read these safety instructions carefully.
2. Keep this User Manual for later reference.
3. Keep this equipment away from fire.
6. Do not leave this equipment in an environment unconditioned, it may damage the
equipment. Operating temperature: -20°C~70°C.
8. Do not operate this equipment in an environment temperature may over
70°C(149° F). The surface temperature of plastic chassis may be hot.
9. All cautions and warnings on the equipment should be noted.
12. Ifthe equipment is not used for a long time, stop recording by setting utility.
13. Never pour any liquid into an opening. This may cause fire or electrical shock.
14. Never open the equipment. For safety reasons, the equipment should be
opened only by qualified service personnel.
15. If one of the following situations arises, get the equipment checked by service
personnel:
„
The power cord or plug is damaged.
„
Liquid has penetrated into the equipment.
„
The equipment has been exposed to moisture.
„
The equipment does not work well, or you cannot get it to work according to
the user's manual.
„
The equipment has been dropped and damaged.
„
The equipment has obvious signs of breakage.
16. CAUTION: The computer is provided with a battery-powered real-time clock cir- cuit.
There is a danger of explosion if battery is incorrectly replaced. Replace only with
same or equivalent type recommended by the manufacture. Discard used batteries
according to the manufacturers instructions.
17. This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
18. CAUTION: Always completely disconnect the power cord from your chassis
whenever you work with the hardware. Do not make connections while the power
is on. Sensitive electronic components can be damaged by sudden power surges.
19. CAUTION: Always ground yourself to remove any static charge before touching the
motherboard, backplane, or add-on cards. Modern electronic devices are very
sensitive to static electric charges. As a safety precaution, use a grounding wrist
strap at all times. Place all electronic components on a static-dissipative surface or in
a static-shielded bag when they are not in the chassis.
20. CAUTION: Any unverified component could cause unexpected damage. To ensure
the correct installation, please always use the components (ex. screws) provided
with the accessory box.
Safety Precaution - Static Electricity
Follow these simple precautions to protect yourself from harm and the products from
damage.
„
To avoid electrical shock, always disconnect the power from your PC chassis
before you work on it. Don't touch any components on the mainboard or other
cards while the system is on.
„
Disconnect power before making any configuration changes. The sudden rush
of power as you connect a jumper or install a card may damage sensitive electronic components.
This product is intended to be supplied by an AA wide temperature battery, if need
further assistance with purchasing the battery, please contact Advantech for further
information.
Chapter 1
1 General Info rmati on
This chapter gives background
information on the TREK-120 Cold
chain Sensor
Sections include:
„
Introduction
„
General Specifications
„
Dimensions
Chapter 1
General Information
RF Operating Frequency
13.56MHz +/- 7kHz (nominal)
RF Output Power
200 mW
RF Output Impendence
50 Ohm
Host Interface
Micro USB
Input Voltage
DC 5V
Operating Temperature
0 ~ 70°C (32 ~ 158°F)
Storage Temperature
-25 ~ 85°C (13 ~ 185°F)
Dimensions
121.63 x 74.18 x 15.6 mm (4.79 x 2.92 x 0.61 in)
Weight
52g (0.11 Ib)
Certifications
CE/FCC/NCC
1.1 Introduction
TREK-120 LoRa temperature and humidity sensors aimed at cold chain logistics and supermarket
applications. In response to industry demands for rugged cold chain fleet management solutions,
Advantech developed its TREK-120 wireless temperature and humidity sensors that can be integrated with
an NFC reader and LoRa gateway for wireless data collection and transmissions. Functioning like a data
logger, TREK-120 sensors are designed to collect and log all temperature and humidity data accurately and
precisely without data losses. The collected data can then be downloaded using an NFC reader (or any
handheld device with NFC capabilities) or wirelessly transmitted to the cloud via a LoRa gateway to enable
real-time monitoring. The inclusion of LoRa technology not only enables long-distance (up to 50 meters)
wireless transmissions with excellent signal penetration, but also reduces the sensor’s overall power
consumption. However, even with the use of NFC and LoRa technology, the sensor battery supports at
least 1 year of operation (depending on operating environment) and can be easily replaced for convenient
management.
To withstand operation in refrigerated vehicles and cold chain logistics fleets, the TREK-120 sensors are
IP65 rated for protection from water and dust ingress and support a wide operating temperature range (20 ~ 65 °C/-4 ~ 149 °F). Moreover, the sensor design is compact, lightweight (108 g), and cableless, and
can be easily installed using magnets or an adhesive backing, eliminating the need for additional cables
and invasive vehicle modifications. The TREK-120 sensors are also equipped with a drop detection sensor
that facilitates product tracking and traceability monitoring. Furthermore, in terms of development
potential, Advantech also provides specific software APIs and SDKs that enable customization and cloudbased applications for centralized fleet management.
For operation in diverse usage environments, TREK-120 sensors can be paired with a LoRa gateway or NFC
reader. Additionally, TREK-120 sensors support management using mobile devices that feature Windows
or Android operating systems to enable uninterrupted cold chain management. Finally, to facilitate
development, Advantech offers software APIs and SDKs (for Windows/Android) that allow system
integrators to develop unique applications and cold chain application software aimed at optimizing vehicle
diagnostics and facilitating cloud-based centralized management.
1.2 General Specifications
NFC Reader
Chapter 1
General Information
1.3 Dimensions
NFC reader
Figure 1.1 TREK-120 dimensions
Chapter 2
2 System Setup
This chapter details system setup
on TREK-120
Sections include:
A Quick Tour of TREK-120
Installation Procedures
Chapter 2
System Setup
2.1 A Quick Tour of TREK-120
Installation Procedures
2.2.1 Setup TREK-120 NFC reader
a. Connect NFC reader to a PC or notebook USB port.
b. Download Cold Chain SDK from the website :
c. Unzip SDK file (Password is the same as the file name) and Launch coldchain_demo.exe.
d. Go to “Setting”, and then select COM port which NFC reader connected then press “Open”.
2.2.2 Setup TREK-120 Temperature/humidity sensor
reader 4 LED area to ensure better transmission quality.)
a. Put TREK-120 on the NFC reader. (Note : Please check NFC logo on TREK-120 close to NFC
b. Go to “ Configure” to setup TREK-120. When you finish all the setting. Please press “Configure
Loggers”. All the setting will be written into TREK-120. Press “ Start logger” , then the TREK-120
will start record temperature/humidity. Press “ Stop logger”, then the TREK-120 will be
stopped record.
c. Go to “Check” to check the configuration of the TREK-120.
d. Go to “Download” to download all data in the TREK-120. When you press “ Download data”, all
data will be shown on the screen. You also can export to .CSV file to save in other disk.
Chapter 3
6 Cold Chain API
This chapter explains the
software API for TREK-120
Directory
Description
bin
DLL & Demo Program
doc
Document and Release Note
include
RFID Driver
sample
The SDK sample source codes
3.1 Introductions
SDK Overview
The SDK is divided into three parts
BIN
DLL
Sample code
DLL provides logic to communicate with the Logger module, most of the developers do not need
to know the details, only need to corresponding process after the interest event trigger or
Read/Write logger sensor.
System Requirement
OS
Windows 7/8/10
Software
Visual Studio 2015
.NET Framework 4.0+
Language
C# only
SDK Package Structure
You can get the following contents by extracting the SDK package:
Using Cold Chain Library
Start Cold Chain
First Step user need to add a reference in Visual C#
1. In Solution Explorer, right-click the project node and click Add Reference.
2. In the Add Reference dialog box, select the tab indicating the type of component you want to
reference.
3. Select the coldchain_lib.dll, and then click OK.
4. Add Namespaces to your code
When the instance is created, the user needs to call the coldchain_init(COM_Port) or
coldchain_gateway_init(COM_Port) method to open the corresponding Serial Port. When the
module is turned on, the system will be initialized in the background. When the initialization is
complete, the user should be able to get the firmware version through coldchain_get_version() or
coldchain_gateway_get_version(). If the version return "Unknown", try again for a while, or check
that your device is properly connected and the power is on.
3.2 Application Programming Interface(API)
Enumeration
AlarmMode Enum
(0) CONTINUOUS - Alarm trigger mode to continuous.
(1) CUMULATIVE - Alarm trigger mode to cumulative.
ButtonActivate Enum
(0) NOT_SUPPORT - The not support button function.
(1) SUPPORT - The support button function.
SensorState Enum
(0) CLOSE_NOT_SETTING - The Logger sensor not setting and not start.
(1) CLOSE_ALREADY_SETTING - The Logger sensor already setting and not start.
(2) START_RECORD - The Logger sensor start up.
WarningType Enum
(0) NORMAL - The temperature and humidity alarm normal status.
(1) HIGH - The temperature and humidity alarm upper status.
(2) LOW - The temperature and humidity alarm lower status.
Structure/Classes
Version Structure
Syntax:
Windows:
Description:
Get the version of firmware.
Members:
lib_version
Point to coldchain_lib Version.
device_firmware_version Point to NFC Reader OR LoRa Gateway Version.
driver_api_version
Point to Jogtek RFID.DLL API Version.
Setting_Logger Structure
Syntax:
Windows:
Description:
Configure logger sensor internal information.
Members:
record_interval_minutes
Set Logger sensor record interval (minutes).
temperature_alarm_upper_bound
Set logger sensor temperature alarm upper.
temperature_alarm_lower_bound
Set logger sensor temperature alarm lower.
temperature_alarm_frequency
Set logger sensor temperature alarm frequency.
temperature_alarm_mode
Temperature according to alarm frequency select type.
Please refer to AlarmMode Enum.
button_activate
Press button to start logger sensor.
Please refer to ButtonActivate Enum.
button_datafull_restart
Press button to restart logger sensor when record data full.
Please refer to ButtonActivate Enum.
humidity_alarm_upper_bound
Set logger sensor humidity alarm upper.
humidity_alarm_lower_bound
Set logger sensor humidity alarm lower.
humidity_alarm_frequency
Set logger sensor humidity alarm frequency.
humidity_alarm_mode
humidity according to alarm frequency select type.
Please refer to AlarmMode Enum.
falling_alarm_bound
Logger sensor falling alarm bound.
external_battery_stop_logger
The external battery voltage is lower than the set value to stop LoRa.
activate_lora_transmission
Enable/Disable lora transmission function.
activate_falling_record
Enable/Disable falling record function.
appointment_time
Appointment time to start logger, Time format "Date / Hour / Minute / Second".
Please refer to StartTime Structure.
loop_recording
LoRa Extend to 60K message and overwrite.
lora_channel
LoRa frequency channel, Value 1 to 5.
lora_data_rate
Data Rate Value : 0 is Low , 1 is High.
Sensor_Internal_Information Structure
Syntax:
Windows:
Description:
Get logger sensor internal information.
Members:
uid
The logger sensor UID number.
button_activate Button start or restart logger sensor.
Please refer to ButtonActivate Enum.
first_record_datetime
Logger sensor the first record time stamp.
record_index
Logger sensor record count.
record_interval_minutes
Logger sensor record interval (minutes).
temperature_alarm_upper_bound
Logger sensor temperature alarm upper.
temperature_alarm_lower_bound
Logger sensor temperature alarm lower.
temperature_alarm_frequency
Logger sensor temperature alarm frequency.
temperature_alarm_mode
Temperature according to alarm frequency select type.
Please refer to AlarmMode Enum.
sensor_status
logger sensor status.
Please refer to SensorState Enum.
internal_battery_voltage
Internal battery voltage.
external_battery_voltage
External battery voltage.
sensor_firmware_version
Logger sensor firmware version.
humidity_alarm_upper_bound
Logger sensor humidity alarm upper.
humidity_alarm_lower_bound
Logger sensor humidity alarm lower.
humidity_alarm_frequency
Logger sensor humidity alarm frequency.
humidity_alarm_mode
Humidity according to alarm frequency select type.
Please refer to AlarmMode Enum.
falling_record_index
Logger sensor falling count.
falling_alarm_bound
Logger sensor falling alarm bound.
over_alert
The LoRA sensor overflow flag.
Please refer to Overflow_Flag Structure.
lora_channel
Get LoRa frequency channel.
lora_data_rate
Get Data Rate Value : 0 is Low , 1 is High.
loop_recording
LoRa Extend to 60K message and overwrite
external_battery_stop_logger
The external battery voltage is lower than the set value to stop LoRa.
external_battery_life
External Battery life (10% ~ 100%).
activate_lora_transmission
Get LoRa Transmission function status.
activate_falling_record
Get Falling Rrecord function status.
appointment_time
Get Appointment Time status.
Please refer to StartTime Structure.
transmission_failed
Logger did not transmit due to collision.
public struct Sensor_Internal_data
Sensor_Internal_data Structure
Syntax:
Windows:
{
public string uid;
public int record_index;
public DateTime[] record_datetime;
public double[] temperature;
public int temperature_alarm_upper_bound;
public int temperature_alarm_lower_bound;
public WarningType[] temperature_Warning;
public double[] humidity;
public int humidity_alarm_upper_bound;
public int humidity_alarm_lower_bound;
public WarningType[] humidity_Warning;
public double internal_battery_voltage;
public double external_battery_voltage;
public int falling_record_index;
public DateTime[] falling_datetime;
public int total_alarm_count;
}
Description:
Get logger sensor record temperature and humidity information.
Members:
uid
The logger sensor UID number.
record_index
Logger sensor record count.
record_datetime[]
One array.
Record each data timestamp.
temperature[]
One array.
Record each data temperature.
temperature_alarm_upper_bound
logger sensor temperature alarm upper.
temperature_alarm_lower_bound
logger sensor temperature alarm lower.
temperature_Warning
Judgment temperature alarm status.
Please refer to WarningType Enum.
humidity[]
One array.
Record each data humidity.
humidity_alarm_upper_bound
logger sensor humidity alarm upper.
humidity_alarm_lower_bound
logger sensor humidity alarm lower.
humidity_Warning
Judgment humidity alarm status.
Please refer to WarningType Enum.
internal_battery_voltage
Internal battery voltage.
external_battery_voltage
External battery voltage.
falling_record_index
Logger sensor falling count.
falling_datetime[]
One array.
Record each falling data timestamp.
total_alarm_count
Temperature and Humidity total alarm count.
public struct Sensor_LoRa_data
Sensor_LoRa_data Structure
Windows:
{
public string uid;
public int record_index;
public string record_datetime;
public double temperature;
public double humidity;
public double internal_battery_voltage;
public double external_battery_voltage;
public int falling_record_index;
public string falling_datetime;
public int rssi;
public int snr;
public int crc;
public string external_battery_life;
public string firmware_version;
public Overflow_Flag over_alert;
}
Description:
Receive LoRa gateway information Structure.
Members:
uid
The loRa sensor UID number.
record_index
LoRa sensor record count.
record_datetime
Receive data timestamp.
temperature
Receive data temperature.
humidity
Receive data humidity.
internal_battery_voltage
Internal battery voltage.
external_battery_voltage
External battery voltage.
falling_record_index
LoRa sensor falling count.
falling_datetime
Receive falling data timestamp.
rssi
The received signal strength indication.
snr
The signal to noise ratio.
crc
The cyclic redundancy check.
external_battery_life
Shows the percentage of external voltage.
firmware_version
LoRa sensor version.
over_alert
The LoRA sensor overflow flag.
Please refer to Overflow_Flag Structure.
public struct Overflow_Flag
Overflow_Flag Structure
Windows:
{
public bool temperature_overflow;
public bool humidity_overflow;
}
Description:
Save the LoRA sensor overflow flag.
public bool falling_overflow;
public bool record_index_overflow;
public bool falling_record_index_overflow;
public bool lora_transmission_stop;
public bool internal_battery_low;
public bool external_battery_low;;
Members:
temperature_overflow
The temperature has exceeded the limit.
humidity_overflow
The humidity is above the limit.
falling_overflow
The number of falling exceeds (or equals) the upper limit.
record_index_overflow
The number of temperature and humidity pens has reached 2000.
falling_record_index_overflow
The number of falling pens has reached 30.
lora_transmission_stop
The external battery voltage is lower than the voltage configuration value before
wireless transmission.
internal_battery_low
The internal battery voltage has been lower than 2.4v in front of the wireless
transmission
external_battery_low
Set the external voltage limit, stop LoRa transmission.
public struct StartTime
StartTime Structure
Windows:
{
public bool auto_startup;
public int date;
public int hour;
public int minute;
public int second;
}
Description:
Save the LoRA sensor overflow flag.
Members:
auto_startup
date
hour
minute
Enable / Disable Appointment Time Function.
Setting Date time.
Setting Hour time.
Setting Minute time.
second
Setting Second time.
Windows
public int coldchain_init(string COM_Port)
APIs
NFC Reader
coldchain_init
Syntax:
Description:
Open the NFC Reader through the serial port.
Parameters:
COM_Port [in]
Specifies which Serial Port Path to connect firmware. For example "COM1"
Returns:
ADVCC_ERR_SUCCESS - On success.
Otherwise see the error code list.
Windows
public int coldchain_deinit()
coldchain_deinit
Syntax:
Description:
Close NFC Reader the serial port.
Parameters:
None
Returns:
ADVCC_ERR_SUCCESS - On success.
Otherwise see the error code list.
Windows
public int coldchain_get_version(ref Version FirmwareVer)
coldchain_get_version
Syntax:
Description:
Get the version of firmware.
Parameters:
FirmwareVer [out]
Please refer to Version Structure.
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
None
Windows
public int coldchain_set_logger(Setting_Logger Logger)
coldchain_set_logger
Syntax:
Description:
Configure logger sensor internal information.
Parameters:
Logger [in]
Please refer to Setting_Logger Structure.
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
The lora_channel and lora_data_rate must be the same as the Gateway setting to receive.
Windows
public int coldchain_start_logger()
coldchain_start_logger
Syntax:
Description:
Start logger sensor to record data.
Parameters:
None
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
None
Windows
public int coldchain_stop_logger()
coldchain_stop_logger
Syntax:
Description:
Stop logger sensor.
Parameters:
None
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
None
Windows
public int coldchain_get_sensor_info(ref Sensor_Info information)
coldchain_get_sensor_info
Syntax:
Description:
Get logger sensor internal information.
Parameters:
information [out]
Please refer to Sensor_Internal_Information Structure.
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
None
Windows
public int coldchain_get_sensor_data(ref Sensor_data OD_data)
coldchain_get_sensor_data
Syntax:
Description:
Get logger sensor record temperature and humidity information.
Parameters:
OD_data [out]
Please refer to Sensor_Internal_data Structure.
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
None
public int coldchain_get_temperature_avg(Sensor_data OD_data, ref
coldchain_get_temperature_avg
Syntax:
Windows
double temperature_avg)
Description:
Get temperature average.
Parameters:
OD_data [in]
Pointer to the node object handle that is the returned by coldchain_get_sensor_data().
temperature_avg [out]
Calculation total temperature average.
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
None
public int coldchain_get_humidity_avg(Sensor_data OD_data, ref double
coldchain_get_humidity_avg
Syntax:
Windows
humidity_avg)
Description:
Get humidity average.
Parameters:
OD_data [in]
Pointer to the node object handle that is the returned by coldchain_get_sensor_data().
humidity_avg [out]
Calculation total humidity average.
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
None
public int coldchain_export_humiture_data(Sensor_data OD_data, string
coldchain_export_humiture_data
Syntax:
Windows
FilePath)
Description:
Export temperature and humidity data to csv.
Parameters:
OD_data [in]
Pointer to the node object handle that is the returned by coldchain_get_sensor_data().
FilePath [in]
Save file location.
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
Save file to .csv format.
public int coldchain_export_falling_data(Sensor_data OD_data, string
coldchain_export_falling_data
Syntax:
Windows
FilePath)
Description:
Export falling data to csv.
Parameters:
OD_data [in]
Pointer to the node object handle that is the returned by coldchain_get_sensor_data().
FilePath [in]
Save file location.
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
Save file to .csv format.
public int coldchain_export_alarm_data(Sensor_data OD_data, string
coldchain_export_alarm_data
Syntax:
Windows
FilePath)
Description:
Export temperature and humidity alarm data to csv.
Parameters:
OD_data [in]
Pointer to the node object handle that is the returned by coldchain_get_sensor_data().
FilePath [in]
Save file location.
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
Save file to .csv format.
public int coldchain_gateway_init(string COM_Port, int lora_channel, int
LoRa Gateway
coldchain_gateway_init
Syntax:
Windows
lora_data_rate)
Description:
Open the LoRa Gateway through the serial port.
Parameters:
COM_Port [in]
Specifies which Serial Port Path to connect firmware. For example "COM1"
lora_channel [in]
Set LoRa frequency channel, Value 1 to 5.
lora_data_rate [in]
Set Data Rate. Value : 0 is Low , 1 is High.
Returns:
ADVCC_ERR_SUCCESS - On success.
Otherwise see the error code list.
Remarks:
The lora_channel and lora_data_rate must be the same as the logger setting to receive.
Windows
public int coldchain_gateway_deinit()
coldchain_gateway_deinit
Syntax:
Description:
Close LoRa Gateway the serial port.
Parameters:
None
Returns:
ADVCC_ERR_SUCCESS - On success.
Otherwise see the error code list.
Windows
public int coldchain_gateway_get_version(ref Version FirmwareVer)
coldchain_gateway_get_version
Syntax:
Description:
Get the Gateway version of firmware.
Parameters:
FirmwareVer [out]
Please refer to Version Structure.
Returns:
MRM_ERR_NO_ERROR - On success.
Otherwise see the error code list.
Remark:
None
CallBack Function