8-port Intelligent RS-232
Universal PCI Communication
Card
User Manual
Copyright
The documentation and the software included with this product are copyrighted 2005 by Advantech Co., Ltd. All rights are reserved. Advantech
Co., Ltd. reserves the right to make improvements in the products
described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or
by any means without the prior written permission of Advantech Co., Ltd.
Information provided in this manual is intended to be accurate and reliable. However, Advantech Co., Ltd. assumes no responsibility for its use,
nor for any infringements of the rights of third parties, which may result
from its use.
Acknowledgements
Intel and Pentium are trademarks of Intel Corporation.
Microsoft Windows and MS-DOS are registered trademarks of
Microsoft Corp.
All other product names or trademarks are properties of their respective
owners.
Part No. 20031625012nd Edition
Printed in TaiwanAugust 2005
PCI-1625U User Manualii
Product Warranty (2 years)
Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for two years
from the date of purchase.
This warranty does not apply to any products which have been repaired or
altered by persons other than repair personnel authorized by Advantech,
or which have been subject to misuse, abuse, accident or improper installation. Advantech assumes no liability under the terms of this warranty as
a consequence of such events.
Because of Advantech’s high quality-control standards and rigorous testing, most of our customers never need to use our repair service. If an
Advantech product is defective, it will be repaired or replaced at no
charge during the warranty period. For out-of-warranty repairs, you will
be billed according to the cost of replacement materials, service time and
freight. Please consult your dealer for more details.
If you think you have a defective product, follow these steps:
1.Collect all the information about the problem encountered. (For
example, CPU speed, Advantech products used, other hardware
and software used, etc.) Note anything abnormal and list any
onscreen messages you get when the problem occurs.
2.Call your dealer and describe the problem. Please have your manual, product, and any helpful information readily available.
3.If your product is diagnosed as defective, obtain an RMA (return
merchandize authorization) number from your dealer. This allows
us to process your return more quickly.
4.Carefully pack the defective product, a fully-completed Repair and
Replacement Order Card and a photocopy proof of purchase date
(such as your sales receipt) in a shippable container. A product
returned without proof of the purchase date is not eligible for warranty service.
5.Write the RMA number visibly on the outside of the package and
ship it prepaid to your dealer.
iii
CE
This product has passed the CE test for environmental specifications
when shielded cables are used for external wiring. We recommend the use
of shielded cables. This kind of cable is available from Advantech. Please
contact your local supplier for ordering information.
FCC Class A
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own
expense.
Technical Support and Assistance
Step 1. Visit the Advantech web site at www.advantech.com/support
where you can find the latest information about the product.
Step 2. Contact your distributor, sales representative, or Advantech's cus-
tomer service center for technical support if you need additional
assistance. Please have the following information ready before
you call:
- Product name and serial number
- Description of your peripheral attachments
- Description of your software (operating system, version, application software, etc.)
- A complete description of the problem
- The exact wording of any error messages
PCI-1625U User Manualiv
Packing List
Before setting up the system, check that the items listed below are
included and in good condition. If any item does not accord with the
table, please contact your dealer immediately.
• 1 x PCI-1625U
• 1 x DB62 loopback for PCI-1625U
• ICOM CD-ROM with Industrial Communication Driver, Utility and
user manual
Safety Precaution - Static Electricity
Follow these simple precautions to protect yourself from harm and the
products from damage.
1.To avoid electrical shock, always disconnect the power from your
PC chassis before you work on it. Don't touch any components on
the CPU card or other cards while the PC is on.
2.Disconnect power before making any configuration changes. The
sudden rush of power as you connect a jumper or install a card may
damage sensitive electronic components.
Table 5.7:Terminal without Handshake ....................... 43
PCI-1625U User Manualviii
2
1
CHAPTER
Introduction
This chapter introduces PCI-1625U, its
accessories and detailed specifications.
Sections include:
• Description
• Features
• Specifications
• Ordering Information
Chapter 1 Introduction
1.1 Description
The intelligent PCI-1625U 8-port RS-232 interface card was designed for
lab and industrial applications where a PC needs to communicate with
terminals, modems, or other instruments. You can install up to four PCI1625U cards for a total of 32 ports in any PCI bus-based PC.
PCI-1625U is virtually a self contained computer. The PCI-1625U card
has an onboard DSP processor that takes over the processing load from
the host PC. When you are transferring large amounts of data from multiple ports, servicing the interrupts alone consumes a large percentage of
the capacity of your computer's CPU. PCI-1625U serves as a high speed,
dedicated interrupt processor.
The processor also has 1 MB of SRAM which can store serial data and
reduce host CPU loading effectively. When PCI-1625U initializes, it
downloads the driver software (which functions like a PC's BIOS) into its
onboard DSP. This improves performance and makes version upgrading
easy so there is no hardware redundancy.
PCI-1625U has a universal PCI connector that is compatible with both
newer 3.3 V signaling systems and the traditional 5V signaling system.
This gives high compatibility and allows usage in diverse systems.
Besides, Advantech provides a convenient utility program, ICOM Tools,
to help users test the PCI card performance by analyzing a port’s status.
It’s easy to use the menu commands and toolbar buttons. ICOM Tools
acts as a PC-based data scope that lets you set a trigger condition, capture
the communication data and monitor the signal status. ICOM Tools is
applicable to all series of Advantech ICOM cards.
PCI-1625U also has many accessories to make usage more convenient.
You can use OPT8AP,OPT8ASP,OPT8BP,OPT8BSP, extending module
boxes to access 8-port RS-232 devices, or OPT8C and OPT8H, extending
cable to access 8-port RS-232 devices, modems and terminals with any
kinds of DTE and DCE connection. You could also use OPT8FP to
access 8-port RS-422 device, OPT8FP is the RS-422 and RS232 converter connection box.
PCI-1625U User Manual2
1.2 Features
• Intelligent 8-port RS-232 serial communication card
• Effectively reduce host CPU loading
• Speeds up to 921.6 kbps
• Onboard 1 MB memory buffer to reduce host CPU loading
• High data throughput rate
• PCI bus specification 2.2 compliant
• PCI universal card (both 3.3 V and 5 V signals)
• I/O address automatically assigned by PCI Plug & Play
• OS supported: Windows 2000/XP
1.3 Specifications
• Processor: TMS320C5402 DSP
• Memory: 1 MB
• Communication Controller: 8 x 16c550c UART
• Serial Interface: 8-port RS-232
• Speed (bps): 50 bps ~ 921.6 kbps
• Bus Interface: PCI bus specification 2.2 compliant
• IRQ: all ports use the same IRQ assigned by PCI Plug & Play
• OPT8AP: 8-Port RS-232 Connection Box/Female DB25 Connect
(DCE) (1.5 m cable connectors with card and connection BOX
included)
• OPT8ASP: 8-Port RS-232 Connection Box/Female DB25 Connector
w/ Surge protection(DCE) (1.5 m cable connectors with card and connection BOX included)
• OPT8BP: 8-Port RS-232 Connection Box/Male DB25 Connector
(DTE) (1.5 m cable connectos with card and connection BOX
included)
• OPT8BSP: 8-Port RS-232 Connection Box/Male DB25 Connector w/
Surge protection (DTE) (1.5 m cable connectors with card and connection BOX included)
• OPT8C: 8-Port RS-232 Octopus Cable/Male DB25 Connect 1 m
• OPT8H: 8-Port RS-232 Octopus Cable/Male DB9 Connect 1 m
• OPT8FP: 8 port RS-422 to RS-232 converter Connection Box with
Isolation Protection (1.5 m cable connectors with card and connection
box included)
PCI-1625U User Manual4
2
2
CHAPTER
Hardware
Configuration
This chapter shows how to get started
with your PCI-1625U card.
Sections include:
• Initial Inspection
• Card Installation
Chapter 2 Hardware Configuration
2.1 Initial Inspection
You should find the following items inside the shipping package:
PCI-1625U Intelligent communication card, DB62 loopback for PCI1625U, and ICOM CD-ROM with Industrial Communication Driver,
Utility, and Intelligent PCI communication card user manual.
We carefully inspected the Intelligent PCI communication card series
mechanically and electrically before we shipped it. It should be free of
marks and scratches and in perfect working order on receipt.
As you unpack the PCI-1625U, check for signs of shipping damage (damaged box, scratches, dents, etc.). If it is damaged or it fails to meet specifications, notify our service department or your local sales representative
immediately. Also notify the carrier. Retain the shipping carton and packing material for inspection by the carrier. After inspection we will make
arrangements to repair or replace the unit.
Discharge your body’s static electric charge by
touching the back of the grounded chassis of
the system unit (metal) before handling the
board. You should avoid contact with materials
that hold a static charge such as plastic, vinyl
and styrofoam. Handle the board only by its
edges to avoid static damage to its integrated
circuits. Avoid touching the exposed circuit
connectors. We also recommend that you use
a grounded wrist strap and place the card on a
static dissipative mat whenever you work with it
When you handle the card, remove it from its protective packaging by
grasping the rear metal panel. Keep the anti-vibration packing. Whenever
you remove the card from the PC, store it in this package for protection.
PCI-1625U User Manual6
2.2 Card Installation
Turn off your PC’s power supply whenever
you install or remove the Intelligent PCI communication card or its cables. Static electricity
can easily damage computer equipment.
Ground yourself by touching the chassis of
the computer (metal) before you touch any
boards.
1.Turn off the computer.
2.Turn the power off to any peripheral devices (such as printers and
monitors).
3.Disconnect the power cord and any other cables from the back of
the computer.
4.Remove the PC’s cover (refer to your user’s guide if necessary).
5.Locate the expansion slots or passive back-plane (at the rear of the
PC) and choose any unused slot.
6.Remove the screw that secures the expansion slot cover to the PC
(save the screw to secure the interface card retaining bracket).
7.Remove the anti-vibration card clamp if supplied.
8.Carefully grasp the upper edge of the Intelligent PCI communica-
tion card.
9.Align the hole in the retaining bracket with the hole on top of the
expansion slot.
10.Align the gold striped edge connector with the expansion slot
socket.
11.Press the board firmly into the socket.
12.Replace the screw in the expansion slot’s retaining bracket.
13.Replace anti-vibration cardholder.
14.Replace the PC’s cover. Connect the cables you removed in step 3.
15.Turn the computer power on.
16.The board is now installed in the computer. See Chapter 5 for infor-
mation on cabling.
7Chapter 2
PCI-1625U User Manual8
2
3
CHAPTER
Driver Setup and
Installation
This chapter shows how to install, verify and uninstall the driver.
Sections include:
• Introduction
• Driver Setup
• Verifying Driver Installation
• Removing PCI ICOM Device
• Driver Uninstallation
Chapter 3 Driver Setup and Installation
3.1 Introduction
This chapter describes the driver installation, configuration and removal
procedures for Windows operating system, including Windows 2000/XP.
We strongly recommend that you install the software driver before
you install the hardware into your system, since this will guarantee a
smooth and trouble-free installation process.
3.2 Driver Setup
Windows 2000/XP supports COM1 to COM256, up to 256 serial ports.
The PCI-1625U driver, however, will assign communication ports automatically. In order to fully utilize Windows 2000/XP advanced features
such as multi-processing and multithreading, we offer pure 32-bit Windows 2000/XP device drivers for PCI-1625U cards. All these drivers conform to Win32 COMM API standard.
Note:We support all 32-bit Windows API but not
included IOCTL_SERIAL_SET_QUEUE_SIZE
and IOCTL_SERIAL_RESET_DEVICE.
PCI-1625U User Manual10
Steps for Windows 2000/XP Driver Setup
Before you install the card into your system, we recommend you install
the driver first. Please follow the steps below for the PCI-1625U Windows 2000/XP driver installation.
1.Insert the companion CD-ROM disc into your CD-ROM drive.
2.The driver setup program will be launched automatically. If the
auto-play function is not enabled on your system, use Windows
Explorer or the Windows Run command to execute autorun.exe on
the companion CD-ROM.
3.After the setup program is launched, you.ll see the following
screen.
11Chapter 3
4.Click the Continue button and the catalogue select page appears.
Then click the Installation button for installation.
5.Click ICOM Card Drivers for installation.
PCI-1625U User Manual12
6.Choose the driver you want to install, then click the hyperlink.
7.You.ll see the following screen. Click Next to continue installation.
13Chapter 3
8.Type user name and company name, then click Next.
9.Click Next to accept the default installation folder, or specify a
folder by clicking the Browse button.
PCI-1625U User Manual14
10.Confirm the program folder and click Next.
11.Click Back to review or change your setting, or click Next to begin
copying files.
15Chapter 3
12.Click Finish to complete the installation.
PCI-1625U User Manual16
3.3 Verifying Driver Installation
After you have installed your card, go to Control Panel/System/Device
Manager to look for the Device Name and COM port that are supposed to
appear after you have installed the driver.
Note:If your device has not been properly installed,
there will be an exclamation mark (!) on the
device name to indicate a conflicting device. If
this is the case, just remove that device and start
the driver installation process all over again.
After driver uninstall is completed, you must
restart your system to re-assign the communication port numbers.
You can check the card properties by double-clicking the specific device
configuration you want to see. On the General tab, you can see the location information that means your card is installed in which PCI slot on the
board.
17Chapter 3
You can also check the COM port properties by double-clicking the specific COM Port device configuration you want to see. On the Properties
sheet, select the specific tabs to see relevant information.
On the General tab, you can see if the COM port works properly. If it
does, you will see a message under the Device status box, stating, “This
device is working properly”. The location shows what COM port is
assigned to what port on the card, and helps configure the ports.
PCI-1625U User Manual18
On the Settings tab, you can check relevant information for a specific
port. On the figures below you can see which COM port is assigned to
which port on the PCI slot. The tab also shows the card model name and
FPGA version. In the default communications parameters box, you
can set up the bits per second, data bits, parity, stop bits and flow control
function.
If you click Advanced, it will pop up the dialogue box. You can adjust
the COM port number here.
19Chapter 3
3.4 Removing PCI ICOM Series Device
1.Access Device Manager in the hardware tab system properties.
2.Click the plus sign (+) on the right of the Ports (COM & LPT)
device category to expand it. Select the specific “Advantech PCI
communication port” you want to remove, and click the Uninstall
button to remove the port you have selected.
PCI-1625U User Manual20
Note:You must remove all used ports setting and device
setting before you remove the device, or there may
be a mistake in the port setting when you install
another card.
3.Click the plus sign (+) on the right of the Advantech ICOM
Adapters device category to expand it, and select Advantech PCI1625U.
Note:We recommend removing the original device set-
tings before installing another model of Advantech
PCI ICOM series device in the same PCI slot.
21Chapter 3
3.5 Driver Uninstallation
1.Insert the ICOM CD and click the driver you want to uninstall.
2.Choose the Modify radio button if you want to save another driver,
or choose the Remove radio button to remove all installed components..
3.Click the Finish button to complete the uninstallation.
PCI-1625U User Manual22
2
4
CHAPTER
ICOM Tools
This chapter provides information on
installation and usage of ICOM Tools.
Sections include:
• Introduction
• Installation
• User Interface of ICOM Tools
Chapter 4 ICOM Tools
4.1 Introduction
Advantech ICOM Tools is a convenient utility that has been designed to
help you test the performance of ICOM cards through analyzing the port
status. It features an easy to use graphical user interface that will soon
make you familiar with testing via menu commands and toolbar buttons.
Advantech ICOM Tools is applicable to all series of Advantech ICOM
cards, and can even be used with other third-party ICOM cards. It is
included for free on the diskette or on the companion CD-ROM with all
Advantech Industrial Communication cards.
4.2 Installation
To begin installation, double-click the ICOM_Tools.exe program icon in
the Tools folder or click the Advantech ICOM Utility hyperlink in the
installation window to launch the ICOM Tools setup program. The setup
program will copy the program files to the destination folder you choose
or to the default installation path (i.e. C:\Program Files\Advantech\ICOM
Tools). A program folder will be created in your Start/Programs menu.
(Later you can just access the program through Start/Program/Advan-tech PCI Comm Tools/COM Examine Tool)
PCI-1625U User Manual24
4.3 User Interface of ICOM Tools
4.3.1 Menu Bar
On the Menu Bar you can select various menu commands to perform
port-testing functions. You can also use the short-cut keys.
Port Submenu
Select: Select the ports you want to configure
Setup: Setup the configuration of a specific port
Close: Close a specific port
Run: Run the test on a specific port
Stop: Stop the test on a specific port
All Ports Submenu
Setup: Setup the configurations of all ports
Run: Run the test on all ports
Stop: Stop the test on all ports
Help Submenu Access Online help
25Chapter 4
4.3.2 Tool Bar
Using the Tool Bar buttons is a more intuitive way to implement the
functions of ICOM Tools.
Port Select: Selects the port(s) you want to perform testing on
Port Setup: Sets up configuration of the port you have
selected
Port Close: Closes the port you have selected
Port Run: Runs the port test on the port you have selected
Port Stop: Stops the port test on the port you have
selected
All Ports Setup: Sets up the configuration of all ports not
running test
All Ports Run: Runs test on all ports
All Ports Stop: Stops test on all ports
Clear Message: Clears messages on Message Logo area
and the Rx length information on the Performance Listing
area
PCI-1625U User Manual26
4.3.3 Com Port Tab
Each Com Port tab represents a specific port you have selected for test
and configuration. On the tab, you can see the Transfer Mode, Port Status, and Message Logo area.
Transfer Modes
You can specify the transfer mode to be Normal, loopback (active) or
loopback (passive).
Normal—allows data to be transmitted and received simultaneously. The
data reception rate is helpful in identifying the performance of a communication card installed on your system.
Loopback- In loopback mode a series of special data will be transmitted,
which are expected to appear on the receiving end. Using the loopback
mode, you can check the integrity of received data and find whether any
error occurred on the transmission line. The active loopback and passive
loopback must work in pair to enable the loopback mode. When a port
operates as active loopback mode, it will send data first and receive data
later. Another port, which operates as passive loopback, will retransmit
any received data on the Rx line and then send these data onto the Tx line.
These two modes will form a logical loop and help to verify the integrity
of data transmitted over the communication link.
27Chapter 4
4.3.4 Port Status
DTR (data-terminal-ready)
DSR (data-set-ready)
RTS (request-to-send)
CTS (clear-to-send)
CD (carrier-detect)
For RS-232 specifications, DTR and RTS are for output signals and can
be toggled on and off by double-clicking the labels (such as DTR, DSR,
RTS, CTS, CD) under the red/green marks. However, if you are using
RTS/CTS for flow control to run the test, you will see the RTS mark
appear in black. This indicates that the RTS can no longer be toggled on/
off since it is controlled by driver itself.
A black mark represents that the function is controlled by the driver itself and therefore not controllable by software.
4.3.5 Message Logo
On the Message Logo area, you can see the relevant messages about the
port(s) you have selected.
For information about specific messages in this area, please refer to Section 4.5, Messages on the Status Bar and Message Logo area.
PCI-1625U User Manual28
4.3.6 Tx Slide Bar
The Tx Slide Bar allows you to control the overall system loading. You
can adjust the transmission rate of your port(s) from 0% to 100%. Just
drag the slide button along the track to adjust the transmission rate.
4.3.7 Performance Listing Area
On the performance listing area, you can see the relevant information,
such as Rx Length (received packet byte length), Bytes/Sec (transmission
rate) and Last Abnormal Status of each port running a test.
4.3.8 Status Bar
The Status Bar is where you can glimpse the current information of the
port you have selected. The Status Bar indicates whether the port is
READY, RUNNING, BUSY or STOPPED, N/A PORT and the configuration information such as baud rate, data bit, stop bit, parity bit and flow
control (represented as 1200 N 8 1 None) settings. Also we can see the
duration of the test in hh:mm:ss format on the right.
For information about specific messages on this area, please refer to Section 4.5, Messages on the Status Bar and Message Logo area.
29Chapter 4
4.4 Using the ICOM Tools Utility
To launch the ICOM Tools testing utility, access Start/Programs/Advantech PCI Comm Tools/COM Examine Tools to start the port testing utility.
4.4.1 Port Selection
Please follow the steps below to make your port selection:
1.Launch ICOM Tools. You will first see the Program Window such
as Figure 4.1. Since you haven’t selected any port for testing yet,
all you can see now is a blank window area.
Figure 4.1: ICOM Tools program window
PCI-1625U User Manual30
2.Select the port(s) you want to test by the Port/Select menu com-
mand or by clicking the Port Select button on the Toolbar, and a
dialog box such as Fig. 2 will appear.
Figure 4.2: Select Port dialog box
Select the port(s) you want to perform test on from the checkboxes next
to each COM port. You can either click the checkbox or double-click the
name(s) of the port(s) to select/deselect port(s) to perform the test on. The
port(s) you selected will immediately appear in the Selected Port field.
Figure 4.3: Ports You Select Will Appear in the Selected Port Checkbox
Group
31Chapter 4
Click OK to bring up the ICOM Tools User Interface such as below:
Figure 4.4: ICOM Tools User Interface
4.4.2 Configuring a Port
You can choose to configure a specific port (or to configure all ports)
before running your test. Just click a Com Port Tab to select the port you
want to configure, and then click the Port Setupbutton or use the
Port/Setup menu command (or if you want to configure all ports at once,
just click the All Ports Setup button or access the All Ports/Setup
menu command) to bring up the Configure Port dialog box such as
below.
PCI-1625U User Manual32
In the Configure Port dialog box, you can configure the Baud Rate, Data
bits, Parity, Stop Bits and the flow control mode for that specific port (or
for all ports). After you have configured all the settings you want to
change, click OKto make this configuration active.
NOTE: When using All Ports Setup button or All Ports/
Setup menu command to configure settings
for all ports, you must take care to stop any ports
that are running test in order to configure them. If
you do not stop the test running on a specific
port, it won’t be configured at all. That is, you get
to configure only the ports that have been
stopped.
Run the Test
After you have completed the configuration of the port(s), you can now
start the test on the port you have selected by clicking the Run button
or accessing the Port/Run menu command (or you want to run all ports at
once, just click the All Ports Run button or access All Ports/Run
menu command).
Once the test is started, you can see relevant test information of port performance on the performance listing area.
Figure 4.5: Test Information on the Performance Listing Area
33Chapter 4
The Performance Listing Area
PortThe com port number
Rx lengthReceived packet length in bytes
Bytes/SecTransmission rate in Bytes/Sec
Last Abnormal StatusLast abnormal status
Stop t he Test
If you want to stop the test on a specific port, just click Port Stop button or access Port/Stop menu command (or if you want to stop test on all
ports, just click All Ports Stop button or access All Ports/Stop menu
command).
You can restart the test by clicking the Run button or accessing the
Port/Run menu command (or if you want to run all ports at once, just
click the All Ports Run button or access All Ports/Run menu command).
4.4.3 Close Port
If you want to close a port, just select the Com Port tab and click Port
Close button or access Port/Close menu command to close the port.
4.4.4 Exit the ICOM Tools utility
To exit the ICOM Tools utility, simply access Port/Exit menu command
or click the Close button on the upper right corner of the program window.
PCI-1625U User Manual34
4.5 Messages on Status Bar and Message Logo Area
Messages appearing on the Status Bar and Message Logo area are helpful
in understanding specific information of your system settings and performance.
4.5.1 Status Bar Messages
BUSY: the port is currently used by another application.
FAIL: the configuration parameters are not accepted by the port
N/A PORT: the port is not available in the system
READY: the port is ready to run or to be configured.
RUNNING: the test is running on the port
STOPPED: the test running on the port has been stopped by the user
35Chapter 4
4.5.2 Message Logo Messages
Port Opened: The user has opened the port
Port Setup Fail: The user has set up the port configuration with parame-
If you choose accessory OPT8AP to connect with PCI-1625U, the female
DB25 connectors of OPT8AP are as shown below.
Table 5.2: PCI-1625U with OPT8AP Female DB25 Pin Assignment
PinSignal
2RxD
3TxD
4CTS
5RTS
6DTR
7GND
20DSR
8DCD
5.1.3 PCI-1625U with OPT8BP, OPT8C
If you choose accessory OPT8BP and OPT8C connects with PCI-1625U,
male DB25 connectors of OPT8BP and OPT8C are as shown below.
Table 5.3: PCI-1625U with OOPT8BP or OPT8C Male DB25 Pin
Assignment
PinSignal
2Txd
3RxD
4RTS
5CTS
6DSR
7GND
20DTR
8DCD
PCI-1625U User Manual40
5.1.4 PCI-1625U with OPT8H
If you choose accessory Opt8H to connect with PCI-1625U, male DB9
connectors of OPT8H are as shown below.
Table 5.4: PCI-1625U with OPT8H male DB9 Pin Assignment
PinSignal
1DCD
2RxD
3TxD
4DTR
5GND
6DSR
7RTS
8CTS
9-
5.1.5 PCI-1625U with OPT8FP
If you choose accessory Opt8FP to connect with PCI-1625U, you could
access RS-422 device through OPT8FP and female DB25 connectors of
OPT8FP are shown as below.
PinSignal
2RxD+
3TxD+
7GND
14RxD-
16TxD-
41Chapter 5
5.2 Wiring
Since the RS-232 interface is not strictly defined, many devices have their
own connection methods, which may ignore some signal lines or define
reserved lines for other functions. It is best to refer to the user manual of
your device for installation instructions. You may find the following
helpful.
In general, DTE (Data Terminal Equipment) refers to the device that is
leading the communication. Examples include PCs, terminals and some
printers. DCE refers to the device being communicated with or controlled. Examples include modems, DSU’s (digital service units), printers
and lab/factory equipment. In some situations, you may be able to get by
with just three lines: data on RxD, TxD and ground.
Table 5.5: Terminal or PC (DTE) Connections
DB25 MaleDB25 Male or Female: Terminal
PinSignalPinSignal
2TxD3RxD
3RxD2TxD
4RTS5CTS
5CTS4RTS
6DSR20 DTR
7GND7GND
20DTR6DSR
8DCD8DCD
PCI-1625U User Manual42
Table 5.6: Modem Connections
DB25 MaleModem (DCE)
PinSignalPinSignal
2TxD2RxD
3RxD3TxD
4RTS4CTS
5CTS5RTS
6DSR6 DTR
7GND7GND
20DTR20DSR
8DCD8DCD
For DTE to DCE connections, use straight-through cable (i.e., you don't
have to reverse lines 2 and 3, lines 4 and 5, and lines 6 and 20 since, in
general, the DCE RS-232 interfaces are reversed themselves).
Table 5.7: Terminal without Handshake
DB-25 MaleTerminal, PC (DTE)
PinSignalPinSignal
2TxD3RxD
3RxD2 TxD
4
5
7GND7GND
6
20
8
RTS —
CTS —
DSR —
DTR —
DCD —
Therefore, if you are not using CTS, RTS, DSR, DTR and DCD signals,
please short pins 4 and 5 together, and please short pins 6, 8, and 20
together.
43Chapter 5
PCI-1625U User Manual44