12
TO-247
1-Cathode
2-Anode
Back of Case -Cathode
1
2
APT60D40B 400V 60A
ULTRAFAST SOFT RECOVERY RECTIFIER DIODE
PRODUCT APPLICATIONS
• Anti-Parallel Diode
PRODUCT FEATURES
• Ultrafast Recovery Times
PRODUCT BENEFITS
• Low Losses
-Switchmode Power Supply
-Inverters
• Free Wheeling Diode
-Motor Controllers
-Converters
• Snubber Diode
• Uninterruptible Power Supply (UPS)
• Induction Heating
• High Speed Rectifiers
• Soft Recovery Characteristics
• Popular TO-247 Package
• Low Forward Voltage
• High Blocking Voltage
• Low Leakage Current
• Low Noise Switching
• Cooler Operation
• Higher Reliability Systems
• Increased System Power
Density
MAXIMUM RATINGS All Ratings: TC = 25°C unless otherwise specified.
Symbol
V
R
V
RRM
V
RWM
IF(AV)
(RMS)
I
F
I
FSM
TJ,T
STG
T
L
Characteristic / Test Conditions
Maximum D.C. Reverse Voltage
Maximum Peak Repetitive Reverse Voltage
Maximum Working Peak Reverse Voltage
Maximum Average Forward Current (T
RMS Forward Current
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
Operating and StorageTemperature Range
Lead Temperature: 0.063" from Case for 10 Sec.
= 70°C, Duty Cycle = 0.5)
C
APT60D40B
400
60
100
600
-55 to 150
300
UNIT
Volts
Amps
°C
STATIC ELECTRICAL CHARACTERISTICS
Symbol
V
I
RM
C
L
USA
405 S.W. Columbia Street Bend, Oregon 97702-1035 Phone: (541) 382-8028 FAX: (541) 388-0364
EUROPE
Avenue J.F. Kennedy Bât B4 Parc Cadéra Nord F-33700 Merignac - France Phone: (33)5 57 92 15 15 FAX: (33) 5 56 47 97 61
Characteristic / Test Conditions
Maximum Forward Voltage I
F
Maximum Reverse Leakage Current VR = VR Rated
Junction Capacitance, V
T
Series Inductance (Lead to Lead 5mm from Base)
S
= 200V
R
APT Website - http://www.advancedpower.com
I
= 60A
F
= 120A
F
IF = 60A, TJ = 150°C
VR = VR Rated, TJ = 125°C
MIN TYP MAX
1.2 1.5
1.5
1.05 1.3
250
500
110
10
UNIT
Volts
µA
pF
nH
053-4001 Rev D
DYNAMIC CHARACTERISTICS
APT60D40B
Symbol
t
rr1
t
rr2
t
rr3
t
fr1
t
fr2
I
RRM1
I
RRM2
Q
rr1
Q
rr2
V
fr1
V
fr2
diM/dt
Characteristic
Reverse Recovery Time, I
= 1.0A, diF/dt = -15A/µs, VR = 30V, TJ = 25°C
F
Reverse Recovery Time TJ = 25°C
= 60A, diF/dt = -480A/µs, VR = 240V TJ = 100°C
I
F
Forward Recovery Time TJ = 25°C
= 60A, diF/dt = 480A/µs, VR = 240V TJ = 100°C
I
F
Reverse Recovery Current TJ = 25°C
= 60A, diF/dt = -480A/µs, VR = 240V TJ = 100°C
I
F
Recovery Charge T
= 25°C
J
IF = 60A, diF/dt = -480A/µs, VR = 240V TJ = 100°C
Forward Recovery Voltage T
= 60A, diF/dt = 480A/µs, VR = 240V TJ = 100°C
I
F
= 25°C
J
Rate of Fall of Recovery Current TJ = 25°C
= 60A, diF/dt = -480A/µs, VR = 240V (See Figure 10) TJ = 100°C
I
F
MIN TYP MAX
55 70
40
65
175
175
10 17
20 30
275
800
6.5
6.5
1250
2700
UNIT
ns
Amps
nC
Volts
A/µs
THERMAL AND MECHANICAL CHARACTERISTICS
Symbol
R
R
W
Torque
Characteristic / Test Conditions
Junction-to-Case Thermal Resistance
θJC
Junction-to-Ambient Thermal Resistance
θJA
Package Weight
T
Maximum Mounting Torque (Screw Type = 6-32 or 3mm Machine)
1.0
, THERMAL IMPEDANCE (°C/W)
JC
θ
Z
0.5
0.1
0.05
0.01
0.005
D=0.5
0.2
0.1
0.05
0.02
0.01
SINGLE PULSE
MIN TYP MAX
0.66
40
0.22
6.1
10
1.1
NOTE:
DM
t
1
P
t
DUTY FACTOR D=t
=+
PEAK T P x Z T
DM JC
UNIT
°C/W
oz
gm
lb•in
N•m
2
/
t
12
CJ
053-4001 Rev D
0.001
-5
10
FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION
-4
10
-3
10
RECTANGULAR PULSE DURATION (SECONDS)
-2
10
10
-1
1.0 10