2
323
2
3
1
Anti-Parallel Parallel
APT2X30D100J APT2X31D100J
414
1
4
SOT-227
APT2X30D100J 1000V 30A
APT2X31D100J 1000V 30A
DUAL DIE ISOTOP® PACKAGE
ULTRAFAST SOFT RECOVERY DUAL RECTIFIER DIODES
PRODUCT APPLICATIONS
• Anti-Parallel Diode
PRODUCT FEATURES
• Ultrafast Recovery Times
-Switchmode Power Supply
-Inverters
• Free Wheeling Diode
-Motor Controllers
-Converters
• Snubber Diode
• Uninterruptible Power Supply (UPS)
• Soft Recovery Characteristics
• Popular SOT-227 Package
• Low Forward Voltage
• High Blocking Voltage
• Induction Heating
• High Speed Rectifiers
• Low Leakage Current
MAXIMUM RATINGS All Ratings: TC = 25°C unless otherwise specified.
PRODUCT BENEFITS
• Low Losses
• Low Noise Switching
• Cooler Operation
• Higher Reliability Systems
• Increased System Power
Density
Symbol
V
V
RRM
V
RWM
IF(AV)
(RMS)
I
F
I
FSM
TJ,T
T
Characteristic / Test Conditions
Maximum D.C. Reverse Voltage
R
Maximum Peak Repetitive Reverse Voltage
Maximum Working Peak Reverse Voltage
Maximum Average Forward Current (T
RMS Forward Current
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
Operating and StorageTemperature Range
STG
Lead Temperature: 0.063" from Case for 10 Sec.
L
STATIC ELECTRICAL CHARACTERISTICS
Symbol
V
I
RM
Characteristic / Test Conditions
Maximum Forward Voltage I
F
Maximum Reverse Leakage Current VR = VR Rated
= 85°C, Duty Cycle = 0.5)
C
I
= 30A
F
= 60A
F
I
= 30A, TJ = 150°C
F
VR = VR Rated, TJ = 125°C
APT2X30/2X31D100J
1000
30
70
210
-55 to 150
300
MIN TYP MAX
2.3
2.1
1.9
250
500
UNIT
Volts
Amps
°C
UNIT
Volts
µA
C
L
USA
405 S.W. Columbia Street Bend, Oregon 97702-1035 Phone: (541) 382-8028 FAX: (541) 388-0364
EUROPE
Avenue J.F. Kennedy Bât B4 Parc Cadéra Nord F-33700 Merignac - France Phone: (33) 5 579215 15 FAX: (33) 556 47 97 61
Junction Capacitance, V
T
Series Inductance (Lead to Lead 5mm from Base)
S
= 200V
R
APT Website - http://www.advancedpower.com
30
10
pF
nH
053-0003 Rev B
DYNAMIC CHARACTERISTICS
Note:
Duty Factor D =
t
1
/
t
2
Peak TJ = PDM x Z
θJC
+ T
C
t
1
t
2
P
DM
APT2X30/2X31D100J
Symbol
t
t
t
t
t
I
RRM1
I
RRM2
Q
Q
V
V
rr1
rr2
rr3
fr1
fr2
Characteristic
Reverse Recovery Time, I
= 1.0A, diF/dt = -15A/µs, VR = 30V, TJ = 25°C
F
Reverse Recovery Time TJ = 25°C
= 30A, diF/dt = -240A/µs, VR = 540V TJ = 100°C
I
F
Forward Recovery Time TJ = 25°C
= 30A, diF/dt = 240A/µs, VR = 540V TJ = 100°C
I
F
Reverse Recovery Current TJ = 25°C
= 30A, diF/dt = -240A/µs, VR = 540V TJ = 100°C
I
F
Recovery Charge T
rr1
IF = 30A, diF/dt = -240A/µs, VR = 540V TJ = 100°C
rr2
Forward Recovery Voltage T
fr1
= 30A, diF/dt = 240A/µs, VR = 540V TJ = 100°C
I
fr2
F
Rate of Fall of Recovery Current TJ = 25°C
diM/dt
= 30A, diF/dt = -240A/µs, VR = 540V (See Figure 10) TJ = 100°C
I
F
THERMAL AND MECHANICAL CHARACTERISTICS
= 25°C
J
= 25°C
J
MIN TYP MAX
60 75
60
120
185
185
613
10 18
180
600
10.4
10.4
450
250
UNIT
ns
Amps
nC
Volts
A/µs
Symbol
R
θJC
R
θJA
V
Isolation
W
T
Torque
1.0
0.5
0.1
0.05
Characteristic / Test Conditions
Junction-to-Case Thermal Resistance
Junction-to-Ambient Thermal Resistance
RMS Voltage (
50-60 Hz Sinusoidal Waveform from Terminals to Mounting Base for 1 Min.)
Package Weight
Maximum Torque (
D=0.5
0.2
0.1
0.05
0.02
0.01
Mounting = 8-32 or 4mm Machine and Terminals = 4mm Machine)
MIN TYP MAX
0.90
20
2500
1.03
29.2
13.6
1.5
UNIT
°C/W
Volts
oz
gm
lb•in
N•m
053-0003 Rev B
, THERMAL IMPEDANCE (°C/W)
JC
θ
Z
0.01
0.005
0.001
SINGLE PULSE
-5
10
FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION
-4
10
-3
10
RECTANGULAR PULSE DURATION (SECONDS)
-2
10
10
-1
1.0 10