Absolute maximum ratings
Symbol Parameter Max ratings Unit
VR Maximum DC reverse Voltage
V
Maximum Peak Repetitive Reverse Voltage
RRM
I
F(A V)
I
RMS Forward Current Duty cycle = 50% TC = 45°C 500
F(RMS)
I
Non-Repetitive Forward Surge Current 8.3ms
FSM
Dual diodes
Power Module
K1
A1/K2
A2
K1
Maximum Average Forward Current
A1/K2
A2
Duty cycle = 50%
V
= 200V
RRM
IC = 400A @ Tc = 80°C
Application
Anti-Parallel diode
Uninterruptible Power Supply (UPS)
Inducti o n heati ng
Welding equipment
High speed rectifiers
Features
Ultra fast recovery times
Soft recovery characteristics
Very low stray inductance
High blocking voltage
High current
Low leakage current
Very low stray inductance
- Symme trical design
- M5 power connectors
High level of integration
Benefits
Outsta ndi ng pe r for mance at hi gh fr eq uenc y
operation
Low losses
Low noise switching
Direct mounting to heatsink (isolated package)
Low junction to case thermal resistance
200 V
TC = 25°C 500
TC = 80°C 400
TC = 45°C
3000
A
These Devices are sensitive to Electrostatic Discharge. Proper Handing Procedures Should Be Followed.
APT website – http://www.advancedpower.com
1 - 4
APTDF400AK20 – Rev 0 May, 2005
APTDF400AK20
All ratings @ Tj = 25°C unless otherwise specified
Electrical Characteristics
Symbol Characteristic Test Conditions Min Typ Max Unit
IF = 400A 1.0 1.1 IF = 800A 1.4 VF Diode Forward Voltage IF = 400A Tj = 125°C 0.9
IRM Maximum Reverse Leakage Current VR = 200V
CT Junction Capacitance VR = 200V 1600 pF
Tj = 25°C 750 Tj = 125°C 1000
Dynamic Characteristics
Symbol Characteristic Test Conditions Min Typ Max Unit
trr Reverse Recovery Time
trr Reverse Recovery Time
Qrr Reverse Recovery Charge
I
Reverse Recovery Current
RRM
trr Reverse Recovery Time 80 ns
Qrr Reverse Recovery Charge 7.64 µC
I
Reverse Recovery Current
RRM
IF=1A, VR=30V di/dt = 400A/µs
IF = 400A
VR = 133V
di/dt = 800A/µs
IF = 400A
VR = 133V
di/dt = 4000A/ µs
Tj = 25°C 39 ns
Tj = 25°C 60
Tj = 125°C 110
Tj = 25°C 800
Tj = 125°C 3360
Tj = 25°C 24
Tj = 125°C 60
Tj = 125°C
176 A
Thermal and package characteristics
Symbol Characteristic Min Typ Max Unit
R
Junction to Case 0.14 °C/W
thJC
V
RMS Isolation Voltage, any terminal to case t =1 min, I isol<1mA, 50/60Hz 2500 V
ISOL
TJ Operating junction temperature range -40 150
T
Storage Temperature Range -40 125
STG
TC Operating Case Temperature -40 100
Torque Mounting torque
Wt Package Weight
To heatsink M6 3 5 For terminals M5 2 3.5
280
V
µA
ns
nC
A
°C
N.m
g
APT website – http://www.advancedpower.com