Datasheet AMS2905CD-2.85, AMS2905CD-2.5, AMS2905CD-1.5, AMS2905CD, AMS2905-5.0 Datasheet (ADMOS)

...
Advanced AMS2905 Monolithic 500mA LOW DROPOUT VOLTAGE REGULATOR
Systems
FEATURES APPLICATIONS
•• Three Terminal Adjustable or Fixed Voltages* •• High Efficiency Linear Regulators
1.5V, 2.5V, 2.85V, 3.3V and 5.0V
•• Operates Down to 1V Dropout •• Battery Chargers
•• Line Regulation: 0.2% Max. •• Sound Cards
•• Load Regulation: 0.4% Max. •• Power Management for Notebook
•• TO-252, SOT-223 and SOT-89 packages •• Battery Powered Instrumentation
GENERAL DESCRIPTION
The AMS2905 series of adjustable and fixed voltage regulators are designed to provide 500mA output current and to operate down to 1V input-to-output differential. The dropout voltage of the device is guaranteed maximum 1.3V at maximum output current, decreasing at lower load currents. On-chip trimming adjusts the reference voltage to 1%. Current limit is also trimmed, minimizing the stress under overload conditions on both the regulator and power source circuitry. The AMS2905 devices are pin compatible with other three-terminal regulators and are offered in the low profile surface mount TO-252(DPAK), SOT-223 and SOT-89 packages.
•• Post Regulators for Switching Supplies
ORDERING INFORMATION:
PACKAGE TYPE OPERATING JUNCTION
SOT-89 TO-252 SOT-223
AMS2905CL AMS2905CD AMS2905 AMS2905CL-1.5 AMS2905CD-1.5 AMS2905-1.5 AMS2905CL-2.5 AMS2905CD-2.5 AMS2905-2.5 AMS2905CL-2.85 AMS2905CD-2.85 AMS2905-2.85 AMS2905CL-3.3 AMS2905CD-3.3 AMS2905-3.3 AMS2905CL-5.0 AMS2905CD-5.0 AMS2905-5.0
*For additional available fixed voltages contact factory.
PIN CONNECTIONS
FIXED VERSION ADJUSTABLE VERSION
1- V
IN
2- Ground 3- V
OUT
1- V
IN
2- Adjust 3- V
OUT
TEMPERATURE
RANGE
0 to 125° C 0 to 125° C 0 to 125° C 0 to 125° C 0 to 125° C 0 to 125° C
SOT-223 Top View
1
2
3
TO-252 Front View
3 2 1
SOT-89 Top View
321
Advanced Monolithic Systems, Inc. 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140
AMS2905
Junction Temperature Range
ABSOLUTE MAXIMUM RATINGS (Note 1)
Power Dissipation Internally limited Thermal Resistance Input Voltage 15V SOT-89 package Operating Control Section Power Transistor Storage temperature Soldering information Lead Temperature (10 sec)
0°C to 125°C
0°C to 150°C
- 65°C to +150°C
300°C
TO-252 package SOT-223 package
* With package soldering to copper area over backside ground plane or internal power plane ϕ 46°C/W to >90°C/W depending on mounting technique and the size of the copper area.
ϕ JA= 110°C/W
ϕ JA= 80°C/W
ϕ JA= 90°C/W*
can vary from
JA
ELECTRICAL CHARACTERISTICS
Electrical Characteristics at I
Parameter Device Conditions Min Typ Max Units
= 0 mA, and TJ = +25°C unless otherwise specified.
OUT
Reference Voltage (Note 2)
Output Voltage (Note 2)
Line Regulation AMS2905
Load Regulation (Notes 2, 3)
AMS2905 I
AMS2905-1.5
AMS2905-2.5
AMS2905-2.85
AMS2905-3.3
AMS2905-5.0
AMS2905-1.5
AMS2905-2.5
AMS2905-2.85
AMS2905-3.3
AMS2905-5.0
AMS2905
AMS2905-1.5
AMS2905-2.5
AMS2905-2.85
AMS2905-3.3
AMS2905-5.0
= 10 mA
OUT
10mA I 0 I
0 I
0 I
0 I
0 I
I
LOAD
3.0V VIN 12V
4.0V VIN 12V
4.35V VIN 12V
4.75V VIN 12V
6.5V VIN 12V
(VIN - V
VIN = 5V, 0 I
VIN = 5V, 0 I
VIN = 5V, 0 I
VIN = 5V, 0 I
VIN = 8V, 0 I
500mA, 1.5V (VIN - V
OUT
500mA , 4.35V VIN 12V
OUT
500mA , 4.35V VIN 12V
OUT
500mA , 4.35V VIN 12V
OUT
500mA , 4.75V VIN 12V
OUT
500mA , 6.5V VIN 12V
OUT
= 10 mA , 1.5V (VIN - V
) =3V, 10mA I
OUT
500mA
OUT
500mA
OUT
500mA
OUT
500mA
OUT
500mA
OUT
OUT
500mA
OUT
OUT
) 12V
) 12V
1.238
1.225
1.485
1.476
2.475
2.460
2.82
2.79
3.267
3.235
4.950
4.900
1.250
1.250
1.500
1.500
2.500
2.500
2.850
2.850
3.300
3.300
5.000
5.000
0.015
0.035
0.3
0.6
0.3
0.6
0.3
0.6
0.5
1.0
0.5
1.0
0.1
0.2
3
6
3
6
3
6
3
7
5
10
1.262
1.270
1.515
1.524
2.525
2.560
2.88
2.91
3.333
3.365
5.050
5.100
0.2
0.2
5
6
6
6
6
6
10
10
10
10
0.3
0.4
10
20
12
20
12
20
15
25
20
35
V V
V V
V V
V V
V V
V V
% %
mV mV
mV mV
mV mV
mV mV
mV mV
% %
mV mV
mV mV
mV mV
mV mV
mV mV
Advanced Monolithic Systems, Inc. 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140
AMS2905
ELECTRICAL CHARACTERISTICS
Electrical Characteristics at I
Parameter Device Conditions Min Typ Max Units
= 0 mA, and TJ = +25°C unless otherwise specified.
OUT
Dropout Voltage (V
- V
OUT
)
IN
Current Limit AMS2905-1.5/-2.5/-2.85/
AMS2905-1.5/-2.5/-2.85/
-3.3/-5.0
V
OUT
(VIN - V
, V
OUT
= 1%, I
REF
) = 5V
= 500mA (Note 4)
OUT
1.1 1.3
1,000
V
mA
-3.3/-5.0
Minimum Load
AMS2905 (VIN - V
) = 12V (Note 5)
OUT
5 10
mA
Current Quiescent Current AMS2905-1.5/-2.5/-2.85/
VIN 12V
5 10
mA
-3.3/-5.0
Ripple Rejection AMS2905
AMS2905-1.5
f =120Hz , C (VIN-V
) = 3V, C
OUT
f =120Hz , C
= 25µF Tantalum, I
OUT
=25µF
ADJ
= 25µF Tantalum, I
OUT
= 500mA,
OUT
= 500mA,
OUT
60 75
60 72
dB
dB
VIN = 6V
AMS2905-2.5
f =120Hz , C
= 25µF Tantalum, I
OUT
= 500mA,
OUT
60 72
dB
VIN = 6V
AMS2905-2.85
f =120Hz , C
= 25µF Tantalum, I
OUT
= 500mA,
OUT
60 72
dB
VIN = 6V
AMS2905-3.3
f =120Hz , C
= 25µF Tantalum, I
OUT
= 500mA
OUT
60 72
dB
VIN = 6.3V
AMS2905-5
f =120Hz , C
= 25µF Tantalum, I
OUT
= 500mA
OUT
60 68
dB
VIN = 8V
Thermal Regulation AMS2905 TA = 25°C, 30ms pulse 0.008 0.04 %W Adjust Pin Current AMS2905
Adjust Pin Current
AMS2905
Change Temperature Stability
10mA I
10mA I
500mA , 1.5V (VIN - V
OUT
500mA , 1.5V (VIN - V
OUT
OUT
OUT
) 12V
) 12V
55
120
0.2 5
0.5
µA µA
µA
% Long Term Stability TA =125°C, 1000Hrs 0.3 1 % RMS Output Noise
(% of V
OUT
)
Thermal Resistance
TA = 25°C , 10Hz f 10kHz
0.003 %
15 °C/W
Junction-to-Case
Parameters identified with boldface type apply over the full operating temperature range.
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. For guaranteed specifications and test conditions, see the
Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed.
Note 2: Line and Load regulation are guaranteed up to the maximum power dissipation of 1.2W for SOT-223 package and 0.9W for SOT-89 package. Power
dissipation is determined by the input/output differential and the output current. Guaranteed maximum power dissipation will not be available over the full input/output range.
Note 3: See thermal regulation specifications for changes in output voltage due to heating effects. Line and load regulation are measured at a constant junction
temperature by low duty cycle pulse testing. Load regulation is measured at the output lead ~1/8” from the package.
Note 4: Dropout voltage is specified over the full output current range of the device. Note 5: Minimum load current is defined as the minimum output current required to maintain regulation. When 1.5V (V
guaranteed to regulate if the output current is greater than 10mA.
- V
) 12V the device is
IN
OUT
Advanced Monolithic Systems, Inc. 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140
APPLICATION HINTS
ADJ
The AMS2905 series of adjustable and fixed regulators are easy to use and are protected against short circuit and thermal overloads. Thermal protection circuitry will shut-down the regulator should the junction temperature exceed 165°C at the sense point. Pin compatible with older three terminal adjustable regulators, these devices offer the advantage of a lower dropout voltage, more precise reference tolerance and improved reference stability with temperature.
Stability
The circuit design used in the AMS2905 series requires the use of an output capacitor as part of the device frequency compensation. The addition of 150µF aluminum electrolytic or a 22µF solid tantalum on the output will ensure stability for all operating conditions. When the adjustment terminal is bypassed with a capacitor to improve the ripple rejection, the requirement for an output capacitor increases. The value of 22µF tantalum or 150µF aluminum covers all cases of bypassing the adjustment terminal. Without bypassing the adjustment terminal smaller capacitors can be used with equally good results. To ensure good transient response with heavy load current changes capacitor values on the order of 100µF are used in the output of many regulators. To further improve stability and transient response of these devices larger values of output capacitor can be used.
Protection Diodes
Unlike older regulators, the AMS2905 family does not need any protection diodes between the adjustment pin and the output and from the output to the input to prevent over-stressing the die. Internal resistors are limiting the internal current paths on the AMS2905 adjustment pin, therefore even with capacitors on the adjustment pin no protection diode is needed to ensure device safety under short-circuit conditions. Diodes between the input and output are not usually needed. Microsecond surge currents of 50A to 100A can be handled by the internal diode between the input and output pins of the device. In normal operations it is difficult to get those values of surge currents even with the use of large output capacitances. If high value output capacitors are used, such as 1000µF to 5000µF and the input pin is instantaneously shorted to ground, damage can occur. A diode from output to input is recommended, when a crowbar circuit at the input of the AMS2905 is used (Figure 1).
AMS2905
D1
V
IN
IN OUT
ADJ
C
10µF
ADJ
+
R
1
R
2
Figure 1.
Output Voltage
The AMS2905 series develops a 1.25V reference voltage between the output and the adjust terminal. Placing a resistor between these two terminals causes a constant current to flow through R1 and down through R2 to set the overall output voltage. This current is normally the specified minimum load
AMS2905
current of 10mA. Because I
is very small and constant it
represents a small error and it can usually be ignored.
AMS2905
V
IN
V
OUT
IN OUT
ADJ
I
ADJ
50µA
= V
(1+ R2/R1)+I
REF
V
REF
R2
ADJ
Figure 2. Basic Adjustable Regulator
Load Regulation
True remote load sensing it is not possible to provide, because the AMS2905 is a three terminal device. The resistance of the wire connecting the regulator to the load will limit the load regulation. The data sheet specification for load regulation is measured at the bottom of the package. Negative side sensing is a true Kelvin connection, with the bottom of the output divider returned to the negative side of the load. The best load regulation is obtained when the top of the resistor divider R1 is connected directly to the case not to the load. If R1 were connected to the load, the effective resistance between the regulator and the load would be:
R1
R2
C
OUT
150µF
V
OUT
V
OUT
R
R1
x ( R2+R1 ) , R
P
= Parasitic Line Resistance
P
Advanced Monolithic Systems, Inc. 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140
APPLICATION HINTS
AMS2905
Connected as shown , R
V
IN
IN OUT
is not multiplied by the divider ratio
P
R
P
PARASITIC
AMS2905
ADJ
LINE RESISTANCE
R1*
R2*
R
L
*CONNECT R1 TO CASE
CONNECT R2 TO LOAD
Figure 3. Connections for Best Load Regulation
In the case of fixed voltage devices the top of R1 is connected Kelvin internally, and the ground pin can be used for negative side sensing.
The total thermal resistance from junction to ambient can be as low as 45°C/W. This requires a reasonable sized PC board with at least on layer of copper to spread the heat across the board and couple it into the surrounding air. Experiments have shown that the heat spreading copper layer does not need to be electrically connected to the tab of the device. The PC material can be very effective at transmitting heat between the pad area, attached to the pad of the device, and a ground plane layer either inside or on the opposite side of the board. Although the actual thermal resistance of the PC material is high, the Length/Area ratio of the thermal resistance between layers is small. The data in Table 1, was taken using 1/16” FR-4 board with 1 oz. copper foil, and it can be used as a rough guideline for estimating thermal resistance. For each application the thermal resistance will be affected by thermal interactions with other components on the board. To determine the actual value some experimentation will be necessary. The power dissipation of the AMS2905 is equal to:
PD = ( VIN - V
OUT
)( I
OUT
) Maximum junction temperature will be equal to: TJ = T
+ PD(Thermal Resistance (junction-to-ambient))
A(MAX)
Maximum junction temperature must not exceed 125°C.
Ripple Rejection
Thermal Considerations
The ripple rejection values are measured with the adjustment pin bypassed. The impedance of the adjust pin capacitor at the ripple
The AMS2905 series have internal power and thermal limiting circuitry designed to protect the device under overload conditions.
However maximum junction temperature ratings of 125°C should not be exceeded under continuous normal load conditions. Careful consideration must be given to all sources of thermal resistance from junction to ambient. For the surface mount
frequency should be less than the value of R1 (normally 100 to 200) for a proper bypassing and ripple rejection approaching the values shown. The size of the required adjust pin capacitor is a function of the input ripple frequency. If R1=100 at 120Hz the adjust pin capacitor should be >13µF. At 10kHz only 0.16µF is needed.
package SOT-223 additional heat sources mounted near the device must be considered. The heat dissipation capability of the PC board and its copper traces is used as a heat sink for the device. The thermal resistance from the junction to the tab for the
AMS2905 is 15°C/W. Thermal resistance from tab to ambient
The ripple rejection will be a function of output voltage, in circuits without an adjust pin bypass capacitor. The output ripple will increase directly as a ratio of the output voltage to the reference voltage (V
can be as low as 30°C/W.
Table 1.
COPPER AREA THERMAL RESISTANCE
TOP SIDE* BACK SIDE BOARD AREA (JUNCTION-TO-AMBIENT)
2500 Sq. mm 2500 Sq. mm 2500 Sq. mm 1000 Sq. mm 2500 Sq. mm 2500 Sq. mm
225 Sq. mm 2500 Sq. mm 2500 Sq. mm
100 Sq. mm 2500 Sq. mm 2500 Sq. mm 1000 Sq. mm 1000 Sq. mm 1000 Sq. mm 1000 Sq. mm 0 1000 Sq. mm
* Tab of device attached to topside copper.
45°C/W 45°C/W 53°C/W 59°C/W 52°C/W 55°C/W
OUT
/ V
REF
).
Advanced Monolithic Systems, Inc. 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140
TYPICAL PERFORMANCE CHARACTERISTICS
AMS2905
Minimum Operating Current (Adjustable Device)
12
9
6
3
MINIMUM OPERATING CURRENT (mA)
0
0 5 10 15 20
INPUT/OUTPUT DIFFERENTIAL (V)
TJ = 125°C
TJ = 25°C
Load Regulation
0.10
I
= 500mA
LOAD
0.05
0
-0.05
-0.10
OUTPUT VOLTAGE DEVIATION (%)
-0.15
-0.20
-50 -25 0 25 50 75 100 125 TEMPERATURE (°C)
Short-Circuit Current
1.25
1.00
0.75
0.50
SHORT CIRCUIT CURRENT (A)
0.25
0
0 5 10 15
INPUT/OUTPUT DIFFERENTIAL
TJ = 125°C
TJ = 25°C
Ripple Rejection vs. Current
100
90
80
70
60
50
40
30
RIPPLE REJECTION (dB)
20
V
10
C C
0
0 0.15 0.3 0.45 0.6
= 5V
OUT
= 25µF
ADJ
= 25µF
OUT
OUTPUT CURRENT (A)
V
RIPPLE
3Vp-p
V
RIPPLE
0.5Vp-p
f
f
RIPPLE
RIPPLE
= 120Hz
= 20Hz
2.0
1.0
0
-1.0
OUTPUT VOLTAGE CHANGE (%)
-2.0
-50 -25 0 25 50 75 100 125 150 TEMPERATURE (°C)
100
90
80
70
60
50
40
30
ADJUST PIN CURRENT (µA)
20
10
0
-50 -25 0 25 50 75 100 125 150 TEMPERATURE (°C)
Advanced Monolithic Systems, Inc. 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140
Adjust Pin CurrentTemperature Stability
PACKAGE DIMENSIONS inches (millimeters) unless otherwise noted.
TO-252 PLASTIC PACKAGE (D)
0.258-0.262
0.023-0.027
(0.584-0.685)
0.020-0.030
(0.508-0.762)
0.175-0.180
(4.191-4.445)
(6.553-6.654)
0.208-0.212
(5.283-5.384)
0.020-0.030
(0.508-0.762)
0.033-0.037
(0.838-0.939)
45.0°
0.057-0.067
(0.144-0.170)
DIA
0.085-0.095
(2.159-2.413)
7.0°
0.030-0.034
(0.762-0.863)
0.038-0.042 (0.965-1.066)
0.235-0.245 (5.969-6.223)
AMS2905
0.264-0.287 (6.71-7.29)
0.025
(0.635)
TYP
(2.235-2.336)
0.130-0.146 (3.30-3.71)
0.088-0.092
0.038
0.099-0.103
(2.514-2.615)
0.030
(0.762)
TYP
(0.965)
TYP
0.018-0.022
(0.451-0.558)
3 LEAD SOT-223 PLASTIC PACKAGE
0.248-0.264
(6.30-6.71)
0.116-0.124 (2.95-3.15)
0.038-0.042 (0.965-1.066)
0.024±0.002 (0.610±0.0508)
D (D3) AMS DRW# 042891
0.033-0.041 (0.84-1.04)
0.012 (0.31)
MIN
10°
MAX
10°-16°
0.025-0.033 (0.64-0.84)
0.010-0.014 (0.25-0.36)
10°-16°
(SOT-223 ) AMS DRW# 042292
0.071 (1.80)
MAX
0.090 (2.29)
NOM
0.025-0.033 (0.64-0.84)
0.181 (4.60)
NOM
Advanced Monolithic Systems, Inc. 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140
PACKAGE DIMENSIONS inches (millimeters) unless otherwise noted (Continued).
SOT-89 PLASTIC PACKAGE (L)
0.173-0.181
0.155-0.167 (3.94-4.25)
0.090-0.102 (2.29-2.60)
(4.40-4.60)
0.064-0.072 (1.62-1.83)
0.035-0.047 (0.89-1.20)
0.055-0.063 (1.40-1.60)
0.084-0.090 (2.13-2.29)
AMS2905
0.014-0.017 (0.35-0.44)
0.059 (1.50)
BSC
0.118 (3.00)
BSC
0.017-0.022 (0.44-0.56)
0.014-0.019 (0.36-0.48)
L (SOT-89 ) AMS DRW# 042392
Advanced Monolithic Systems, Inc. 6680B Sierra Lane, Dublin, CA 94568 Phone (925) 556-9090 Fax (925) 556-9140
Loading...