BEFORE YOU BEGIN...
READ ALL INSTRUCTIONS
TEST FOR SIGNAL STRENGTH AND NOISE...
using appropriate test equipment. It is necessary to test the installation in the actual operating environment. The amount and types of line loads may reduce the strength of the transmitted signal and/or electrical noise may cause interference with the transmitted signal. Proper installation may require additional couplers, filters or repeaters. Special coupling devices are required to allow signal to be distributed to all phases and zero-crossings in multi-phase and multi-transformer distributions.
RF124
A10 120 VAC, 20A, Isolated Contact Relay Fixture Receiver,
Standard and Extended Addressing
INSTALLATION
IF YOU HAVE ANY QUESTIONS...
Consult your nearest Engineered System Center (ESC) for additional information.
There are no field repairable assemblies on this unit. If service is needed, the unit must be returned to the ESC where purchased. Contact your ESC for return details.
CAUTION! Make all connections with the POWER OFF to avoid injury to the installer or damage to the device. WARNING: SHOCK HAZARD. Do not use the manual ON/OFF switch on the RF to disconnect the load for service. Signal can cause it to turn ON.
1. Strip 3/4" of insulation from the ends of the conductors and make connections as shown in the Wiring Diagram. Connect line and neutral to the BLACK and WHITE flying leads. Connect the load between a power source and the two BLUE wires. When the relay is turned ON the LED illuminates.
2. Check connections to be sure they are tight and no bare conductors are exposed.
3. Make sure the load or installation does not exceed the device rating.
4. Install into a 4" x 4" electrical box. Clean the mounting surface, remove the protective film from the adhesive tape and firmly press the module in place.
NOTE! Do not install within four inches of fluorescent ballast.
The RF124 features two operating modes: Normal Mode and Configuration Mode. The Normal Mode is the state in which the device performs its primary function. The Configuration Mode allows the user to specify the address by which the device may be controlled, and allows the user to enable “All Lights On, All Units Off, All Lights Off commands” (disabled when address is set) or disable “polite mode” and enable “rude mode”.
ADVANCED CONTROL TECHNOLOGIES, INC. Indianapolis, Indiana 46278
0692-01
1
RF124 Installation Instructions
P/D 013106
OPERATION
CONFIGURING
CHECKOUT
If the RF124 address is configured to a standard code address:
The RF124 will respond to standard code On, Off, and Status Request commands.
The RF124 will respond with standard code Status On or Status Off commands when it receives the standard code Status Request command.
If the RF124 address is configured to an extended code address:
The RF124 will respond to standard code On and Off commands addressed to the Letter code and Unit code of its extended code address.
It will also respond to extended code On, Off, and Status Request commands.
The RF124 will respond with extended code Status On or Status Off commands when it receives the extended code Status Request command.
To set the Address:
Press and hold the configuration button for 3 seconds. After 3 seconds, release the button. The status LED should be on steady. The RF124 can now be addressed.
Using a transmitter, transmit the desired address twice in succession. The transmissions must be separated by at least six zero crossings (approximately 60mS, dependent on line frequency). The RF124 status LED will blink twice to indicate acceptance of desired address. The unit defaults to polite when the address is configured.
Each time program mode is entered to change the configuration of the unit, your must first enter the address of the unit before any feature is configured. Have this address information available.
If no address transmission is accepted by the RF124 while in program mode, and program mode is exited, or the unit times out after one minute, the address of the unit as well as the features previously programmed will remain active.
To enable “All Lights On, All Units Off, All Lights Off commands”:
To enable each command, transmit the command twice in succession (separated by at least six zero crossings). The status LED will blink 6 times when All Lights On is enabled, 8 times when All Units Off is enabled, and 10 times when All Lights Off is enabled.
To disable “polite mode” and enable “rude mode”:
Transmit the configured address twice more in succession (separated by at least six zero crossings). The status LED will blink 4 times. If configuring this feature immediately after the address is entered, only a single address transmission is required. The LED will still blink 4 times to confirm entry.
To exit configuration mode:
To exit configuration mode, press the configuration button. The status LED will indicate the last known state (ON or OFF). The RF124 will exit configuration mode and reenter normal mode after one minute.
To check remote operation:
To check contact operation and Contact Status Transmission Manually:
RF124 Installation Instructions P/D 013106
Using a transmitter, transmit the address and any configured commands to ensure the module controls the load in response to remote control.
Test for signal strength and noise once again using AT004 or appropriate PCC test equip­ment.
Tap the program button once to close the contacts and to transmit the Status ON command. The connected load will turn ON.
Tap the program button once again to open the contacts and to transmit the Status OFF command. The connected load will turn OFF.
Ensure that the Status ON or OFF transmissions are accurate, and that the strength of these signals are adequate, with the use of the AT004 test tool or other appropriate PCC test equipment.